Modelling the Sensing Radius of a Coaxial Probe for Dielectric Characterisation of Biological Tissues

The open-ended coaxial probe is the most common measurement tool used to dielectrically characterize biological tissues. Most healthy and malignant biological tissues are macroscopically heterogeneous, with the exception of a few tissues, such as liver. Heterogeneous biological samples are dielectri...

Full description

Bibliographic Details
Main Authors: Alessandra La Gioia, Martin O'Halloran, Emily Porter
Format: Article
Language:English
Published: IEEE 2018-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/8444380/
_version_ 1828964267821367296
author Alessandra La Gioia
Martin O'Halloran
Emily Porter
author_facet Alessandra La Gioia
Martin O'Halloran
Emily Porter
author_sort Alessandra La Gioia
collection DOAJ
description The open-ended coaxial probe is the most common measurement tool used to dielectrically characterize biological tissues. Most healthy and malignant biological tissues are macroscopically heterogeneous, with the exception of a few tissues, such as liver. Heterogeneous biological samples are dielectrically characterized by defining the dielectric properties of each tissue type constituting the sample. In order to accurately characterize a specific tissue type with a coaxial probe, it is fundamental that only the tissue of interest is contained within the probe sensing volume, which is defined by the sensing radius and sensing depth. In the literature, several studies have investigated the sensing depth with bilayer or multilayer heterogeneous tissues. However, in this paper, we examine the sensing radius through concentrically heterogeneous tissues. In particular, samples composed of two different concentric tissues were modeled to estimate the minimum width of the homogenous tissue region required to accurately acquire the corresponding dielectric properties. As recent studies have indicated that the sensing radius depends on the dielectric properties of the interrogated tissue, in this paper, the sensing radius of a coaxial probe has been numerically quantified across a wide range of scenarios, involving different tissues with varying dielectric contrasts. The numerical results indicate that: 1) the sensing radius increases with the contrast in permittivity between the constituent tissues and 2) the sensing radius is highly dependent on the permittivity of the tissue closest to the inner conductor of the probe. Finally, the numerical outcome has been confirmed with dielectric measurements performed on animal tissues.
first_indexed 2024-12-14T10:45:39Z
format Article
id doaj.art-edbd7869c1b5491394ba580aad695b25
institution Directory Open Access Journal
issn 2169-3536
language English
last_indexed 2024-12-14T10:45:39Z
publishDate 2018-01-01
publisher IEEE
record_format Article
series IEEE Access
spelling doaj.art-edbd7869c1b5491394ba580aad695b252022-12-21T23:05:26ZengIEEEIEEE Access2169-35362018-01-016465164652610.1109/ACCESS.2018.28667038444380Modelling the Sensing Radius of a Coaxial Probe for Dielectric Characterisation of Biological TissuesAlessandra La Gioia0https://orcid.org/0000-0002-1996-6767Martin O'Halloran1Emily Porter2Translational Medical Device Laboratory, National University of Ireland Galway, Galway, IrelandTranslational Medical Device Laboratory, National University of Ireland Galway, Galway, IrelandTranslational Medical Device Laboratory, National University of Ireland Galway, Galway, IrelandThe open-ended coaxial probe is the most common measurement tool used to dielectrically characterize biological tissues. Most healthy and malignant biological tissues are macroscopically heterogeneous, with the exception of a few tissues, such as liver. Heterogeneous biological samples are dielectrically characterized by defining the dielectric properties of each tissue type constituting the sample. In order to accurately characterize a specific tissue type with a coaxial probe, it is fundamental that only the tissue of interest is contained within the probe sensing volume, which is defined by the sensing radius and sensing depth. In the literature, several studies have investigated the sensing depth with bilayer or multilayer heterogeneous tissues. However, in this paper, we examine the sensing radius through concentrically heterogeneous tissues. In particular, samples composed of two different concentric tissues were modeled to estimate the minimum width of the homogenous tissue region required to accurately acquire the corresponding dielectric properties. As recent studies have indicated that the sensing radius depends on the dielectric properties of the interrogated tissue, in this paper, the sensing radius of a coaxial probe has been numerically quantified across a wide range of scenarios, involving different tissues with varying dielectric contrasts. The numerical results indicate that: 1) the sensing radius increases with the contrast in permittivity between the constituent tissues and 2) the sensing radius is highly dependent on the permittivity of the tissue closest to the inner conductor of the probe. Finally, the numerical outcome has been confirmed with dielectric measurements performed on animal tissues.https://ieeexplore.ieee.org/document/8444380/Biological tissuescoaxial probedielectric measurementelectromagnetic simulationssensing radius
spellingShingle Alessandra La Gioia
Martin O'Halloran
Emily Porter
Modelling the Sensing Radius of a Coaxial Probe for Dielectric Characterisation of Biological Tissues
IEEE Access
Biological tissues
coaxial probe
dielectric measurement
electromagnetic simulations
sensing radius
title Modelling the Sensing Radius of a Coaxial Probe for Dielectric Characterisation of Biological Tissues
title_full Modelling the Sensing Radius of a Coaxial Probe for Dielectric Characterisation of Biological Tissues
title_fullStr Modelling the Sensing Radius of a Coaxial Probe for Dielectric Characterisation of Biological Tissues
title_full_unstemmed Modelling the Sensing Radius of a Coaxial Probe for Dielectric Characterisation of Biological Tissues
title_short Modelling the Sensing Radius of a Coaxial Probe for Dielectric Characterisation of Biological Tissues
title_sort modelling the sensing radius of a coaxial probe for dielectric characterisation of biological tissues
topic Biological tissues
coaxial probe
dielectric measurement
electromagnetic simulations
sensing radius
url https://ieeexplore.ieee.org/document/8444380/
work_keys_str_mv AT alessandralagioia modellingthesensingradiusofacoaxialprobefordielectriccharacterisationofbiologicaltissues
AT martinohalloran modellingthesensingradiusofacoaxialprobefordielectriccharacterisationofbiologicaltissues
AT emilyporter modellingthesensingradiusofacoaxialprobefordielectriccharacterisationofbiologicaltissues