Robust Control of Heat Exchangers

This work deals with the design and application of a neuro-fuzzy controller to a heat exchanger and with possibilities to use the coefficient diagram method for heat exchanger control. The heat exchanger is a tubular one and it is used for pre-heating of kerosene by hot water. The heat exchanger can...

Full description

Bibliographic Details
Main Authors: A. Vasickaninová, M. Bakošová
Format: Article
Language:English
Published: AIDIC Servizi S.r.l. 2012-09-01
Series:Chemical Engineering Transactions
Online Access:https://www.cetjournal.it/index.php/cet/article/view/7224
_version_ 1819172150694641664
author A. Vasickaninová
M. Bakošová
author_facet A. Vasickaninová
M. Bakošová
author_sort A. Vasickaninová
collection DOAJ
description This work deals with the design and application of a neuro-fuzzy controller to a heat exchanger and with possibilities to use the coefficient diagram method for heat exchanger control. The heat exchanger is a tubular one and it is used for pre-heating of kerosene by hot water. The heat exchanger can be represented as a system with interval parametric uncertainty. Fuzzy logic control has emerged as one of the most fruitful areas in fuzzy set theory, and many practical applications in both industry and household appliances, as well as studies on the theory itself, have been reported in many works. Coefficient Diagram Method gives control systems that are very stable and robust, system responses without overshoot and very small settling time. The controller design by coefficient diagram method is based on the choice of the coefficients of the characteristic polynomial of the closed loop system according to the convenient performance criteria such as equivalent time constant, stability indices, and stability limits. Most processes are nonlinear, and their control is a difficult yet important problem. The heat exchanger is an example one such nonlinear process. In the presented paper, the performance of set point tracking and disturbance rejection in two controller methods is investigated. Initially, the third order plus dead time model of the process was obtained. Then, the neuro-fuzzy controller and controller using the coefficient diagram method were designed. Finally, the performances of the two controllers are compared. The simulations of control were done in Matlab/Simulink environment. The presented experimental results show applicability of mentioned approaches to safer control of nonlinear process. The control response obtained by CDM controller has smaller overshoots. On the other side, the use of the neuro-fuzzy controller led to smaller consumption of the heating medium.
first_indexed 2024-12-22T20:02:37Z
format Article
id doaj.art-eddffb1a50224d0d84896ee7d12ef870
institution Directory Open Access Journal
issn 2283-9216
language English
last_indexed 2024-12-22T20:02:37Z
publishDate 2012-09-01
publisher AIDIC Servizi S.r.l.
record_format Article
series Chemical Engineering Transactions
spelling doaj.art-eddffb1a50224d0d84896ee7d12ef8702022-12-21T18:14:15ZengAIDIC Servizi S.r.l.Chemical Engineering Transactions2283-92162012-09-012910.3303/CET1229228Robust Control of Heat ExchangersA. VasickaninováM. BakošováThis work deals with the design and application of a neuro-fuzzy controller to a heat exchanger and with possibilities to use the coefficient diagram method for heat exchanger control. The heat exchanger is a tubular one and it is used for pre-heating of kerosene by hot water. The heat exchanger can be represented as a system with interval parametric uncertainty. Fuzzy logic control has emerged as one of the most fruitful areas in fuzzy set theory, and many practical applications in both industry and household appliances, as well as studies on the theory itself, have been reported in many works. Coefficient Diagram Method gives control systems that are very stable and robust, system responses without overshoot and very small settling time. The controller design by coefficient diagram method is based on the choice of the coefficients of the characteristic polynomial of the closed loop system according to the convenient performance criteria such as equivalent time constant, stability indices, and stability limits. Most processes are nonlinear, and their control is a difficult yet important problem. The heat exchanger is an example one such nonlinear process. In the presented paper, the performance of set point tracking and disturbance rejection in two controller methods is investigated. Initially, the third order plus dead time model of the process was obtained. Then, the neuro-fuzzy controller and controller using the coefficient diagram method were designed. Finally, the performances of the two controllers are compared. The simulations of control were done in Matlab/Simulink environment. The presented experimental results show applicability of mentioned approaches to safer control of nonlinear process. The control response obtained by CDM controller has smaller overshoots. On the other side, the use of the neuro-fuzzy controller led to smaller consumption of the heating medium.https://www.cetjournal.it/index.php/cet/article/view/7224
spellingShingle A. Vasickaninová
M. Bakošová
Robust Control of Heat Exchangers
Chemical Engineering Transactions
title Robust Control of Heat Exchangers
title_full Robust Control of Heat Exchangers
title_fullStr Robust Control of Heat Exchangers
title_full_unstemmed Robust Control of Heat Exchangers
title_short Robust Control of Heat Exchangers
title_sort robust control of heat exchangers
url https://www.cetjournal.it/index.php/cet/article/view/7224
work_keys_str_mv AT avasickaninova robustcontrolofheatexchangers
AT mbakosova robustcontrolofheatexchangers