Study on the Lightning Protection Performance for a 110 kV Non-Shield-Wired Overhead Line with Anti-Thunder and Anti-Icing Composite Insulators

Due to micro landforms and climate, the 110 kV transmission lines crossing the mountain areas are exposed to severe icing conditions for both their high voltage (HV) conductors and shield wires during the winter. Ice accumulation on the shield wire causes excessive sag, which leads to a reduced clea...

Full description

Bibliographic Details
Main Authors: Jianping Hu, Ting Zhu, Jianlin Hu, Zhen Fang, Ruihe Zhang
Format: Article
Language:English
Published: MDPI AG 2023-01-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/16/2/815
_version_ 1797443190019588096
author Jianping Hu
Ting Zhu
Jianlin Hu
Zhen Fang
Ruihe Zhang
author_facet Jianping Hu
Ting Zhu
Jianlin Hu
Zhen Fang
Ruihe Zhang
author_sort Jianping Hu
collection DOAJ
description Due to micro landforms and climate, the 110 kV transmission lines crossing the mountain areas are exposed to severe icing conditions for both their high voltage (HV) conductors and shield wires during the winter. Ice accumulation on the shield wire causes excessive sag, which leads to a reduced clearance between earth and HV wires, and could eventually result in tripping of the line due to phase-to-ground flashover. Due to the lack of effective de-icing techniques for the shield wires, removing them completely from the existing overhead line (OHL) structure becomes a reasonable solution to prevent icing accidents. Nevertheless, the risk of exposure to lightning strikes increased significantly after the shield wires were removed. In order to cope with this, the anti-thunder and anti-icing composite insulator (AACI) is installed on the OHLs. In this article, the 110 kV transmission line without shield wire is considered. The shielding failure after installation of the AACIs is studied using the lightning strike simulation models established in the ATP software. The lightning stroke flashover tests are carried out to examine the shielding failures on various designs for the AACIs. Assuming the tower’s earth resistance is 30 Ω, the LWL of back flashover and direct flashover are 630.88 kA and 261.33 kA, respectively, after the installation of AACIs on an unearthed OHL. Due to the unique mechanism of the AACI, the operational voltage level and the height of the pylon have a neglectable influence on its lightning withstand level (LWL). When the length of the parallel protective gap increases from 450 mm to 550 mm, the lightning trip-out rate decreases from 0.104 times/100 km·a to 0.014 times/100 km·a, and the drop rate reaches 86.5%. Therefore, increasing the gap distance for the AACI to provide additional clearance is proven to be an effective method to reduce the shielding failure rates for non-shield-wired OHLs.
first_indexed 2024-03-09T12:52:26Z
format Article
id doaj.art-ede03c343a3247e2a28ec3919283bc7d
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-03-09T12:52:26Z
publishDate 2023-01-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-ede03c343a3247e2a28ec3919283bc7d2023-11-30T22:04:27ZengMDPI AGEnergies1996-10732023-01-0116281510.3390/en16020815Study on the Lightning Protection Performance for a 110 kV Non-Shield-Wired Overhead Line with Anti-Thunder and Anti-Icing Composite InsulatorsJianping Hu0Ting Zhu1Jianlin Hu2Zhen Fang3Ruihe Zhang4Disaster Prevention and Reduction Center of State Grid Hunan Electric Power Corporation, Changsha 410129, ChinaState Key Laboratory of Power Transmission Equipment & System Security and New Technology of Chongqing University, Chongqing 400044, ChinaState Key Laboratory of Power Transmission Equipment & System Security and New Technology of Chongqing University, Chongqing 400044, ChinaDisaster Prevention and Reduction Center of State Grid Hunan Electric Power Corporation, Changsha 410129, ChinaState Key Laboratory of Power Transmission Equipment & System Security and New Technology of Chongqing University, Chongqing 400044, ChinaDue to micro landforms and climate, the 110 kV transmission lines crossing the mountain areas are exposed to severe icing conditions for both their high voltage (HV) conductors and shield wires during the winter. Ice accumulation on the shield wire causes excessive sag, which leads to a reduced clearance between earth and HV wires, and could eventually result in tripping of the line due to phase-to-ground flashover. Due to the lack of effective de-icing techniques for the shield wires, removing them completely from the existing overhead line (OHL) structure becomes a reasonable solution to prevent icing accidents. Nevertheless, the risk of exposure to lightning strikes increased significantly after the shield wires were removed. In order to cope with this, the anti-thunder and anti-icing composite insulator (AACI) is installed on the OHLs. In this article, the 110 kV transmission line without shield wire is considered. The shielding failure after installation of the AACIs is studied using the lightning strike simulation models established in the ATP software. The lightning stroke flashover tests are carried out to examine the shielding failures on various designs for the AACIs. Assuming the tower’s earth resistance is 30 Ω, the LWL of back flashover and direct flashover are 630.88 kA and 261.33 kA, respectively, after the installation of AACIs on an unearthed OHL. Due to the unique mechanism of the AACI, the operational voltage level and the height of the pylon have a neglectable influence on its lightning withstand level (LWL). When the length of the parallel protective gap increases from 450 mm to 550 mm, the lightning trip-out rate decreases from 0.104 times/100 km·a to 0.014 times/100 km·a, and the drop rate reaches 86.5%. Therefore, increasing the gap distance for the AACI to provide additional clearance is proven to be an effective method to reduce the shielding failure rates for non-shield-wired OHLs.https://www.mdpi.com/1996-1073/16/2/815non-shield-wired overhead linesanti-thunder and anti-icing composite insulatorlightning withstand levelshielding failureparallel clearancelightning trip rate
spellingShingle Jianping Hu
Ting Zhu
Jianlin Hu
Zhen Fang
Ruihe Zhang
Study on the Lightning Protection Performance for a 110 kV Non-Shield-Wired Overhead Line with Anti-Thunder and Anti-Icing Composite Insulators
Energies
non-shield-wired overhead lines
anti-thunder and anti-icing composite insulator
lightning withstand level
shielding failure
parallel clearance
lightning trip rate
title Study on the Lightning Protection Performance for a 110 kV Non-Shield-Wired Overhead Line with Anti-Thunder and Anti-Icing Composite Insulators
title_full Study on the Lightning Protection Performance for a 110 kV Non-Shield-Wired Overhead Line with Anti-Thunder and Anti-Icing Composite Insulators
title_fullStr Study on the Lightning Protection Performance for a 110 kV Non-Shield-Wired Overhead Line with Anti-Thunder and Anti-Icing Composite Insulators
title_full_unstemmed Study on the Lightning Protection Performance for a 110 kV Non-Shield-Wired Overhead Line with Anti-Thunder and Anti-Icing Composite Insulators
title_short Study on the Lightning Protection Performance for a 110 kV Non-Shield-Wired Overhead Line with Anti-Thunder and Anti-Icing Composite Insulators
title_sort study on the lightning protection performance for a 110 kv non shield wired overhead line with anti thunder and anti icing composite insulators
topic non-shield-wired overhead lines
anti-thunder and anti-icing composite insulator
lightning withstand level
shielding failure
parallel clearance
lightning trip rate
url https://www.mdpi.com/1996-1073/16/2/815
work_keys_str_mv AT jianpinghu studyonthelightningprotectionperformancefora110kvnonshieldwiredoverheadlinewithantithunderandantiicingcompositeinsulators
AT tingzhu studyonthelightningprotectionperformancefora110kvnonshieldwiredoverheadlinewithantithunderandantiicingcompositeinsulators
AT jianlinhu studyonthelightningprotectionperformancefora110kvnonshieldwiredoverheadlinewithantithunderandantiicingcompositeinsulators
AT zhenfang studyonthelightningprotectionperformancefora110kvnonshieldwiredoverheadlinewithantithunderandantiicingcompositeinsulators
AT ruihezhang studyonthelightningprotectionperformancefora110kvnonshieldwiredoverheadlinewithantithunderandantiicingcompositeinsulators