Performance enhancement of fin and tube heat exchanger employing curved delta winglet vortex generator with circular punched holes

The generation of vortices has recently gained attention as a potential passive technique for improving air-side heat transfer in a fin and tube heat exchanger. This study proposes novel configurations of a curved delta winglet vortex generator (CDWVG) with and without circular holes to improve heat...

Full description

Bibliographic Details
Main Authors: Prashant Saini, Atul Dhar, Satvasheel Powar
Format: Article
Language:English
Published: Elsevier 2023-11-01
Series:International Journal of Thermofluids
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2666202723001672
_version_ 1797401654368141312
author Prashant Saini
Atul Dhar
Satvasheel Powar
author_facet Prashant Saini
Atul Dhar
Satvasheel Powar
author_sort Prashant Saini
collection DOAJ
description The generation of vortices has recently gained attention as a potential passive technique for improving air-side heat transfer in a fin and tube heat exchanger. This study proposes novel configurations of a curved delta winglet vortex generator (CDWVG) with and without circular holes to improve heat transfer in FTHEs. The present study utilizes a three-dimensional numerical analysis to investigate the thermal-hydraulic performance analysis of fin and tube heat exchanger (FTHE) with curved delta winglet vortex generators (CDWVG) with or without circular holes, operating across a wide Reynolds number range (i.e., from 400 to 2000). In addition to being arranged in vertical and horizontal configurations, the CDWVGs are oriented in the same way as the flow direction. Therefore, the pressure distribution, temperature distribution, and flow structure distribution of an FTHE with a four-in-line circular tube configuration are analyzed and compared between FTHE without vortex generator (VG) and five different configurations of CDWVG (i.e., CDWVG without hole, CDWVG with 1 hole, CDWVG with 2 holes, CDWVG with 3 holes and CDWVG with 6 holes). The pressure drop (ΔP), London area goodness factor (LAGF) (j/f), Nusselt number (Nu), and Colburn factor (j) are also used to evaluate the thermo-hydraulic performance of FTHE. The FHTE performance with CDWVGs can be affected by the number of punched holes, which is evaluated using a dimensionless number including Performance Evaluation Criteria (PEC), Colburn factor, etc. The thermo-hydraulic efficiency of the FTHE is improved significantly by using CDWVGs with circular punched holes. Nusselt number decreases across all the VG configurations (i.e., CDWVG without hole, CDWVG with 1 hole, CDWVG with 2 holes, CDWVG with 3 holes, and CDWVG with 6 holes) due to the lower flow resistance. Compared to other CDWVG configurations, the 6-hole configuration of CDWVG is the most effective. The Nusselt number of CDWVG with 6 holes increases by 77.25% and 42.51% at Reynolds numbers of 400 and 2000, with respect to fin and tube heat exchangers without vortex generator, respectively. On the other hand, friction is decreased by 5.11%. Therefore, when considering the London area goodness factor, CDWVG with six holes is found to be superior to other CDWVG configurations.
first_indexed 2024-03-09T02:14:14Z
format Article
id doaj.art-ee25609523904d02b9a98165360aa43b
institution Directory Open Access Journal
issn 2666-2027
language English
last_indexed 2024-03-09T02:14:14Z
publishDate 2023-11-01
publisher Elsevier
record_format Article
series International Journal of Thermofluids
spelling doaj.art-ee25609523904d02b9a98165360aa43b2023-12-07T05:30:48ZengElsevierInternational Journal of Thermofluids2666-20272023-11-0120100452Performance enhancement of fin and tube heat exchanger employing curved delta winglet vortex generator with circular punched holesPrashant Saini0Atul Dhar1Satvasheel Powar2School of Mechanical & Materials Engineering, Indian Institute of Technology Mandi, Mandi, Himachal Pradesh 175005, IndiaSchool of Mechanical & Materials Engineering, Indian Institute of Technology Mandi, Mandi, Himachal Pradesh 175005, IndiaSchool of Mechanical & Materials Engineering, Indian Institute of Technology Mandi, Mandi, Himachal Pradesh 175005, India; School of Technology and Business Studies, Energy Technology, Högskolan Dalarna, Falun, Sweden 791 88, Europe; Corresponding author.The generation of vortices has recently gained attention as a potential passive technique for improving air-side heat transfer in a fin and tube heat exchanger. This study proposes novel configurations of a curved delta winglet vortex generator (CDWVG) with and without circular holes to improve heat transfer in FTHEs. The present study utilizes a three-dimensional numerical analysis to investigate the thermal-hydraulic performance analysis of fin and tube heat exchanger (FTHE) with curved delta winglet vortex generators (CDWVG) with or without circular holes, operating across a wide Reynolds number range (i.e., from 400 to 2000). In addition to being arranged in vertical and horizontal configurations, the CDWVGs are oriented in the same way as the flow direction. Therefore, the pressure distribution, temperature distribution, and flow structure distribution of an FTHE with a four-in-line circular tube configuration are analyzed and compared between FTHE without vortex generator (VG) and five different configurations of CDWVG (i.e., CDWVG without hole, CDWVG with 1 hole, CDWVG with 2 holes, CDWVG with 3 holes and CDWVG with 6 holes). The pressure drop (ΔP), London area goodness factor (LAGF) (j/f), Nusselt number (Nu), and Colburn factor (j) are also used to evaluate the thermo-hydraulic performance of FTHE. The FHTE performance with CDWVGs can be affected by the number of punched holes, which is evaluated using a dimensionless number including Performance Evaluation Criteria (PEC), Colburn factor, etc. The thermo-hydraulic efficiency of the FTHE is improved significantly by using CDWVGs with circular punched holes. Nusselt number decreases across all the VG configurations (i.e., CDWVG without hole, CDWVG with 1 hole, CDWVG with 2 holes, CDWVG with 3 holes, and CDWVG with 6 holes) due to the lower flow resistance. Compared to other CDWVG configurations, the 6-hole configuration of CDWVG is the most effective. The Nusselt number of CDWVG with 6 holes increases by 77.25% and 42.51% at Reynolds numbers of 400 and 2000, with respect to fin and tube heat exchangers without vortex generator, respectively. On the other hand, friction is decreased by 5.11%. Therefore, when considering the London area goodness factor, CDWVG with six holes is found to be superior to other CDWVG configurations.http://www.sciencedirect.com/science/article/pii/S2666202723001672Curved delta winglet vortex generatorVortex generator with circular holesLondon area goodness factorFin and tube heat exchanger
spellingShingle Prashant Saini
Atul Dhar
Satvasheel Powar
Performance enhancement of fin and tube heat exchanger employing curved delta winglet vortex generator with circular punched holes
International Journal of Thermofluids
Curved delta winglet vortex generator
Vortex generator with circular holes
London area goodness factor
Fin and tube heat exchanger
title Performance enhancement of fin and tube heat exchanger employing curved delta winglet vortex generator with circular punched holes
title_full Performance enhancement of fin and tube heat exchanger employing curved delta winglet vortex generator with circular punched holes
title_fullStr Performance enhancement of fin and tube heat exchanger employing curved delta winglet vortex generator with circular punched holes
title_full_unstemmed Performance enhancement of fin and tube heat exchanger employing curved delta winglet vortex generator with circular punched holes
title_short Performance enhancement of fin and tube heat exchanger employing curved delta winglet vortex generator with circular punched holes
title_sort performance enhancement of fin and tube heat exchanger employing curved delta winglet vortex generator with circular punched holes
topic Curved delta winglet vortex generator
Vortex generator with circular holes
London area goodness factor
Fin and tube heat exchanger
url http://www.sciencedirect.com/science/article/pii/S2666202723001672
work_keys_str_mv AT prashantsaini performanceenhancementoffinandtubeheatexchangeremployingcurveddeltawingletvortexgeneratorwithcircularpunchedholes
AT atuldhar performanceenhancementoffinandtubeheatexchangeremployingcurveddeltawingletvortexgeneratorwithcircularpunchedholes
AT satvasheelpowar performanceenhancementoffinandtubeheatexchangeremployingcurveddeltawingletvortexgeneratorwithcircularpunchedholes