CONSIDERATION OF THE IMPACT OF HIGH HARMONICS WHEN SELECTING THE CONDUCTOR CROSS-SECTIONS OF LINES OF OUTDOOR LIGHTING

The operating mode of the lighting line depends on the correct choice of conductor cross section. The magnitude of the cross section has an influence on the provision of the required voltage levels on the light sources. The choice of the conductor cross section has been fulfilled based on calculatio...

Full description

Bibliographic Details
Main Authors: V. B. Kozlovskaya, V. N. Kalechyts
Format: Article
Language:Russian
Published: Belarusian National Technical University 2017-11-01
Series:Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
Subjects:
Online Access:https://energy.bntu.by/jour/article/view/1097
_version_ 1797879778579054592
author V. B. Kozlovskaya
V. N. Kalechyts
author_facet V. B. Kozlovskaya
V. N. Kalechyts
author_sort V. B. Kozlovskaya
collection DOAJ
description The operating mode of the lighting line depends on the correct choice of conductor cross section. The magnitude of the cross section has an influence on the provision of the required voltage levels on the light sources. The choice of the conductor cross section has been fulfilled based on calculations of the operating mode of the standard line of outdoor lighting specified in the article. Luminaries with high pressure sodium lamps connected through electromagnetic ballasts were used as sources of light. When choosing the conductor cross section of light lines a number of simplifications are commonly used. Attention is paid to the choice of sections without such assumptions: the inductive resistance of conductors is taken into account; the power of the luminaire depends on the voltage level in it. Luminaries with high pressure sodium lamps are the sources of high harmonics. Three variants of calculation are demonstrated depending on the accounting (or non-accounting) of high odd harmonics. The methods of calculating the mode of the lighting line are also presented in the article. The calculation is performed with the aid of Mathcad software. Operating parameters for each phase of the line (i.e. voltage in the items of the scheme, power, currents, power, and voltage losses in all the sections) were determined. The diagrams of the voltage distribution at items of the lighting line for three variants of calculation are plotted for various sections of aluminum conductors. On this basis the choice of the optimum magnitude of the conductor cross section of the lighting line was made. The obtained results of different calculation variants are compared. The comparison of the results obtained with the use of various methods of calculation was made. The impact of high harmonics on the operating mode of the line under consideration has been analyzed. The presence of high harmonics causes an increase of voltage losses, the distortion of sinusoidal voltage. The current of neutral conductor is comparable with the current of phase conductors, besides, the harmonics multiple of 3 are of great importance as they influence on the magnitude of the current.
first_indexed 2024-04-10T02:53:43Z
format Article
id doaj.art-ee38f08698bd4d3389d576cdf996fc70
institution Directory Open Access Journal
issn 1029-7448
2414-0341
language Russian
last_indexed 2024-04-10T02:53:43Z
publishDate 2017-11-01
publisher Belarusian National Technical University
record_format Article
series Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
spelling doaj.art-ee38f08698bd4d3389d576cdf996fc702023-03-13T07:41:50ZrusBelarusian National Technical UniversityIzvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika1029-74482414-03412017-11-0160654455710.21122/1029-7448-2017-60-6-544-5571058CONSIDERATION OF THE IMPACT OF HIGH HARMONICS WHEN SELECTING THE CONDUCTOR CROSS-SECTIONS OF LINES OF OUTDOOR LIGHTINGV. B. Kozlovskaya0V. N. Kalechyts1Белорусский национальный технический университетБелорусский национальный технический университетThe operating mode of the lighting line depends on the correct choice of conductor cross section. The magnitude of the cross section has an influence on the provision of the required voltage levels on the light sources. The choice of the conductor cross section has been fulfilled based on calculations of the operating mode of the standard line of outdoor lighting specified in the article. Luminaries with high pressure sodium lamps connected through electromagnetic ballasts were used as sources of light. When choosing the conductor cross section of light lines a number of simplifications are commonly used. Attention is paid to the choice of sections without such assumptions: the inductive resistance of conductors is taken into account; the power of the luminaire depends on the voltage level in it. Luminaries with high pressure sodium lamps are the sources of high harmonics. Three variants of calculation are demonstrated depending on the accounting (or non-accounting) of high odd harmonics. The methods of calculating the mode of the lighting line are also presented in the article. The calculation is performed with the aid of Mathcad software. Operating parameters for each phase of the line (i.e. voltage in the items of the scheme, power, currents, power, and voltage losses in all the sections) were determined. The diagrams of the voltage distribution at items of the lighting line for three variants of calculation are plotted for various sections of aluminum conductors. On this basis the choice of the optimum magnitude of the conductor cross section of the lighting line was made. The obtained results of different calculation variants are compared. The comparison of the results obtained with the use of various methods of calculation was made. The impact of high harmonics on the operating mode of the line under consideration has been analyzed. The presence of high harmonics causes an increase of voltage losses, the distortion of sinusoidal voltage. The current of neutral conductor is comparable with the current of phase conductors, besides, the harmonics multiple of 3 are of great importance as they influence on the magnitude of the current.https://energy.bntu.by/jour/article/view/1097наружное освещениеосветительная линиясветильниксечение проводникавысшие гармоникипотери напряжениямоделирование режима
spellingShingle V. B. Kozlovskaya
V. N. Kalechyts
CONSIDERATION OF THE IMPACT OF HIGH HARMONICS WHEN SELECTING THE CONDUCTOR CROSS-SECTIONS OF LINES OF OUTDOOR LIGHTING
Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
наружное освещение
осветительная линия
светильник
сечение проводника
высшие гармоники
потери напряжения
моделирование режима
title CONSIDERATION OF THE IMPACT OF HIGH HARMONICS WHEN SELECTING THE CONDUCTOR CROSS-SECTIONS OF LINES OF OUTDOOR LIGHTING
title_full CONSIDERATION OF THE IMPACT OF HIGH HARMONICS WHEN SELECTING THE CONDUCTOR CROSS-SECTIONS OF LINES OF OUTDOOR LIGHTING
title_fullStr CONSIDERATION OF THE IMPACT OF HIGH HARMONICS WHEN SELECTING THE CONDUCTOR CROSS-SECTIONS OF LINES OF OUTDOOR LIGHTING
title_full_unstemmed CONSIDERATION OF THE IMPACT OF HIGH HARMONICS WHEN SELECTING THE CONDUCTOR CROSS-SECTIONS OF LINES OF OUTDOOR LIGHTING
title_short CONSIDERATION OF THE IMPACT OF HIGH HARMONICS WHEN SELECTING THE CONDUCTOR CROSS-SECTIONS OF LINES OF OUTDOOR LIGHTING
title_sort consideration of the impact of high harmonics when selecting the conductor cross sections of lines of outdoor lighting
topic наружное освещение
осветительная линия
светильник
сечение проводника
высшие гармоники
потери напряжения
моделирование режима
url https://energy.bntu.by/jour/article/view/1097
work_keys_str_mv AT vbkozlovskaya considerationoftheimpactofhighharmonicswhenselectingtheconductorcrosssectionsoflinesofoutdoorlighting
AT vnkalechyts considerationoftheimpactofhighharmonicswhenselectingtheconductorcrosssectionsoflinesofoutdoorlighting