Reliability of ultrasound in the assessment of muscle thickness in critically ill children

Introduction: Ultrasound has been used to quantify and qualify muscle morphology in critically ill children and can detect changes in muscle thickness. The aim of this study was to assess the reliability of ultrasound measurement of muscle thickness in critically ill children and to compare the asse...

Full description

Bibliographic Details
Main Authors: Jéssica Knisspell de Oliveira, Camila Wohlgemuth Schaan, Cristiano Kohler Silva, Taila Cristina Piva, Ian Teixeira e Sousa, Francisco Bruno, Janice Luisa Lukrafka
Format: Article
Language:Spanish
Published: Elsevier 2023-06-01
Series:Anales de Pediatría (English Edition)
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S234128792300100X
_version_ 1797809883274280960
author Jéssica Knisspell de Oliveira
Camila Wohlgemuth Schaan
Cristiano Kohler Silva
Taila Cristina Piva
Ian Teixeira e Sousa
Francisco Bruno
Janice Luisa Lukrafka
author_facet Jéssica Knisspell de Oliveira
Camila Wohlgemuth Schaan
Cristiano Kohler Silva
Taila Cristina Piva
Ian Teixeira e Sousa
Francisco Bruno
Janice Luisa Lukrafka
author_sort Jéssica Knisspell de Oliveira
collection DOAJ
description Introduction: Ultrasound has been used to quantify and qualify muscle morphology in critically ill children and can detect changes in muscle thickness. The aim of this study was to assess the reliability of ultrasound measurement of muscle thickness in critically ill children and to compare the assessments made by an expert with those made by inexperienced sonographers. Material and methods: Cross-sectional observational study conducted in the paediatric intensive care unit of a tertiary care university hospital in Brazil. The sample included patients aged 1 month to 12 years who received invasive mechanical ventilation for at least 24 h. Ultrasound images of the biceps brachii/brachialis and quadriceps femoris were obtained by one experienced sonographer and several inexperienced sonographers. We assessed intrarater and inter-rater reliability by means of the intraclass correlation coefficient (ICC) and Bland-Altman plot analysis. Results: Muscle thickness was measured in 10 children with a mean age of 15.5 months. The mean thickness of the assessed muscles as 1.14 cm for the biceps brachii/brachialis (standard deviation [SD], 0.27) and 1.85 cm for the quadriceps femoris (SD, 0.61). The intrarater and inter-rater reliability were good for all sonographers (ICC > 0.81). The differences were small, there was no significant bias in the Bland-Altman plots and all measurements were within the limits of agreement, except for 1 measurement of biceps and quadriceps. Conclusion: Sonography can be used in critically ill children to accurately assess changes in muscle thickness, even by different evaluators. More studies are needed to establish a standardised approach to the use of ultrasound for monitoring muscle loss in order to incorporate it in clinical practice. Resumen: Introducción: La ecografía se ha utilizado para cuantificar y calificar la morfología muscular de niños críticamente enfermos, detectando posibles cambios en el grosor muscular. El objetivo del estudio fue evaluar la fiabilidad de la medición por ecografía del grosor muscular en niños críticamente enfermos y comparar la evaluación de un examinador experto con la de examinadores con poca experiencia. Material y métodos: Estudio observacional transversal en la unidad de cuidados intensivos pediátricos de un hospital universitario de tercer nivel en Brasil. Se incluyeron pacientes entre 1 mes y 12 años que recibieron ventilación mecánica invasiva durante un mínimo de 24 horas. Se obtuvieron imágenes ecográficas del bíceps braquial/braquial y cuádriceps femoral en evaluaciones realizadas por un ecografista experimentado y ecografistas inexpertos. La concordancia intra- e interevaluador se estableció mediante el coeficiente de correlación intraclase (CCI) y el análisis gráfico de Bland-Altman. Resultados: Se midió el grosor muscular en 10 niños con una edad media de 15,5 meses. El grosor medio de los músculos evaluados fue de 1,14 cm ± 0,27 para el bíceps braquial/braquial y de 1,85 cm ± 0,61 para el cuádriceps femoral. La fiabilidad intraevaluador e interevaluador fue muy buena (CCI > 0,81) para todos los ecografistas. Las diferencias fueron pequeñas, sin detectarse en el análisis de los gráficos de Bland-Altman, y todas las mediciones estuvieron dentro de los límites de concordancia, excepto una medición de bíceps y cuádriceps. Conclusión: La ecografía se puede utilizar en niños en estado crítico para evaluar con precisión los cambios en el grosor muscular, incluso por diferentes evaluadores. Se necesitan más estudios para establecer un enfoque estandarizado en el uso de esta herramienta para la monitorización de la pérdida muscular con el fin de incorporar su uso en la práctica clínica.
first_indexed 2024-03-13T06:59:36Z
format Article
id doaj.art-eeac856b34e8449fa5ae3aa72d1136dd
institution Directory Open Access Journal
issn 2341-2879
language Spanish
last_indexed 2024-03-13T06:59:36Z
publishDate 2023-06-01
publisher Elsevier
record_format Article
series Anales de Pediatría (English Edition)
spelling doaj.art-eeac856b34e8449fa5ae3aa72d1136dd2023-06-07T04:48:28ZspaElsevierAnales de Pediatría (English Edition)2341-28792023-06-01986411417Reliability of ultrasound in the assessment of muscle thickness in critically ill childrenJéssica Knisspell de Oliveira0Camila Wohlgemuth Schaan1Cristiano Kohler Silva2Taila Cristina Piva3Ian Teixeira e Sousa4Francisco Bruno5Janice Luisa Lukrafka6Programa de Posgrado en Pediatría, Universidade Federal de Ciências da Saúde de Porto Alegre, Porto Alegre (RS), Brasil; Corresponding author.Hospital de Clínicas de Porto Alegre, Porto Alegre (RS), BrasilHospital de Clínicas de Porto Alegre, Porto Alegre (RS), BrasilHospital de Clínicas de Porto Alegre, Porto Alegre (RS), BrasilPrograma de Posgrado en Salud Infantil y Adolescente, Universidade Federal do Rio Grande do Sul, Porto Alegre (RS), BrasilHospital de Clínicas de Porto Alegre, Porto Alegre (RS), BrasilPrograma de Posgrado en Pediatría, Universidade Federal de Ciências da Saúde de Porto Alegre, Porto Alegre (RS), BrasilIntroduction: Ultrasound has been used to quantify and qualify muscle morphology in critically ill children and can detect changes in muscle thickness. The aim of this study was to assess the reliability of ultrasound measurement of muscle thickness in critically ill children and to compare the assessments made by an expert with those made by inexperienced sonographers. Material and methods: Cross-sectional observational study conducted in the paediatric intensive care unit of a tertiary care university hospital in Brazil. The sample included patients aged 1 month to 12 years who received invasive mechanical ventilation for at least 24 h. Ultrasound images of the biceps brachii/brachialis and quadriceps femoris were obtained by one experienced sonographer and several inexperienced sonographers. We assessed intrarater and inter-rater reliability by means of the intraclass correlation coefficient (ICC) and Bland-Altman plot analysis. Results: Muscle thickness was measured in 10 children with a mean age of 15.5 months. The mean thickness of the assessed muscles as 1.14 cm for the biceps brachii/brachialis (standard deviation [SD], 0.27) and 1.85 cm for the quadriceps femoris (SD, 0.61). The intrarater and inter-rater reliability were good for all sonographers (ICC > 0.81). The differences were small, there was no significant bias in the Bland-Altman plots and all measurements were within the limits of agreement, except for 1 measurement of biceps and quadriceps. Conclusion: Sonography can be used in critically ill children to accurately assess changes in muscle thickness, even by different evaluators. More studies are needed to establish a standardised approach to the use of ultrasound for monitoring muscle loss in order to incorporate it in clinical practice. Resumen: Introducción: La ecografía se ha utilizado para cuantificar y calificar la morfología muscular de niños críticamente enfermos, detectando posibles cambios en el grosor muscular. El objetivo del estudio fue evaluar la fiabilidad de la medición por ecografía del grosor muscular en niños críticamente enfermos y comparar la evaluación de un examinador experto con la de examinadores con poca experiencia. Material y métodos: Estudio observacional transversal en la unidad de cuidados intensivos pediátricos de un hospital universitario de tercer nivel en Brasil. Se incluyeron pacientes entre 1 mes y 12 años que recibieron ventilación mecánica invasiva durante un mínimo de 24 horas. Se obtuvieron imágenes ecográficas del bíceps braquial/braquial y cuádriceps femoral en evaluaciones realizadas por un ecografista experimentado y ecografistas inexpertos. La concordancia intra- e interevaluador se estableció mediante el coeficiente de correlación intraclase (CCI) y el análisis gráfico de Bland-Altman. Resultados: Se midió el grosor muscular en 10 niños con una edad media de 15,5 meses. El grosor medio de los músculos evaluados fue de 1,14 cm ± 0,27 para el bíceps braquial/braquial y de 1,85 cm ± 0,61 para el cuádriceps femoral. La fiabilidad intraevaluador e interevaluador fue muy buena (CCI > 0,81) para todos los ecografistas. Las diferencias fueron pequeñas, sin detectarse en el análisis de los gráficos de Bland-Altman, y todas las mediciones estuvieron dentro de los límites de concordancia, excepto una medición de bíceps y cuádriceps. Conclusión: La ecografía se puede utilizar en niños en estado crítico para evaluar con precisión los cambios en el grosor muscular, incluso por diferentes evaluadores. Se necesitan más estudios para establecer un enfoque estandarizado en el uso de esta herramienta para la monitorización de la pérdida muscular con el fin de incorporar su uso en la práctica clínica.http://www.sciencedirect.com/science/article/pii/S234128792300100XCuidado crítico pediátricoEcografíaFiabilidadGrosor muscularNiños
spellingShingle Jéssica Knisspell de Oliveira
Camila Wohlgemuth Schaan
Cristiano Kohler Silva
Taila Cristina Piva
Ian Teixeira e Sousa
Francisco Bruno
Janice Luisa Lukrafka
Reliability of ultrasound in the assessment of muscle thickness in critically ill children
Anales de Pediatría (English Edition)
Cuidado crítico pediátrico
Ecografía
Fiabilidad
Grosor muscular
Niños
title Reliability of ultrasound in the assessment of muscle thickness in critically ill children
title_full Reliability of ultrasound in the assessment of muscle thickness in critically ill children
title_fullStr Reliability of ultrasound in the assessment of muscle thickness in critically ill children
title_full_unstemmed Reliability of ultrasound in the assessment of muscle thickness in critically ill children
title_short Reliability of ultrasound in the assessment of muscle thickness in critically ill children
title_sort reliability of ultrasound in the assessment of muscle thickness in critically ill children
topic Cuidado crítico pediátrico
Ecografía
Fiabilidad
Grosor muscular
Niños
url http://www.sciencedirect.com/science/article/pii/S234128792300100X
work_keys_str_mv AT jessicaknisspelldeoliveira reliabilityofultrasoundintheassessmentofmusclethicknessincriticallyillchildren
AT camilawohlgemuthschaan reliabilityofultrasoundintheassessmentofmusclethicknessincriticallyillchildren
AT cristianokohlersilva reliabilityofultrasoundintheassessmentofmusclethicknessincriticallyillchildren
AT tailacristinapiva reliabilityofultrasoundintheassessmentofmusclethicknessincriticallyillchildren
AT ianteixeiraesousa reliabilityofultrasoundintheassessmentofmusclethicknessincriticallyillchildren
AT franciscobruno reliabilityofultrasoundintheassessmentofmusclethicknessincriticallyillchildren
AT janiceluisalukrafka reliabilityofultrasoundintheassessmentofmusclethicknessincriticallyillchildren