A mine-used frequency converter filter device
The mine-used frequency converter is connected with motor through a long cable, and there is phenomenon of voltage reflection in transmission process of pulse width modulation(PWM) pulse, which causes spike voltage at the motor end and seriously affects operation reliability of frequency conversion...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | zho |
Published: |
Editorial Department of Industry and Mine Automation
2020-05-01
|
Series: | Gong-kuang zidonghua |
Subjects: | |
Online Access: | http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.17504 |
_version_ | 1819017993390129152 |
---|---|
author | RONG Xiang SHI Han JIANG Dezhi SUI Xianming WANG Yue |
author_facet | RONG Xiang SHI Han JIANG Dezhi SUI Xianming WANG Yue |
author_sort | RONG Xiang |
collection | DOAJ |
description | The mine-used frequency converter is connected with motor through a long cable, and there is phenomenon of voltage reflection in transmission process of pulse width modulation(PWM) pulse, which causes spike voltage at the motor end and seriously affects operation reliability of frequency conversion driving system. At present, mine-used flame-proof frequency converter usually adopts series output reactor to suppress spike voltage, but suppression effect is limited. And the methods of suppressing spike voltage by using RC filter device and LRC filter device mainly aim at 380 V and 660 V frequency converter, which cannot meet requirement of suppressing spike voltage by 1 140 V frequency converter in underground coal mine. In view of the spike phenomenon caused by long-distance transmission of long cable, the effects of motor load, PWM rising time and cable length on the spike voltage in practical application were analyzed. The reflection coefficient of long cable terminal is not sensitive to change of motor load, and influence of motor load can be ignored in design process of filter parameters. The longer the rising time of PWM and the shorter the cable length, the smaller the spike voltage at the end of the motor.According to the above analysis, combined with cable length and device power loss, a design scheme of LRC filter device suitable for 1 140 V frequency converter in underground coal mine was proposed. Before PWM pulse signal is introduced into the long cable, the LRC filter device is used to delay PWM rising time, so as to achieve the purpose of suppressing spike voltage and high du/dt. Simulation and experimental results verify effectiveness of the filter device. |
first_indexed | 2024-12-21T03:12:21Z |
format | Article |
id | doaj.art-eed112b6d9844e1f96c67de8b392d928 |
institution | Directory Open Access Journal |
issn | 1671-251X |
language | zho |
last_indexed | 2024-12-21T03:12:21Z |
publishDate | 2020-05-01 |
publisher | Editorial Department of Industry and Mine Automation |
record_format | Article |
series | Gong-kuang zidonghua |
spelling | doaj.art-eed112b6d9844e1f96c67de8b392d9282022-12-21T19:17:56ZzhoEditorial Department of Industry and Mine AutomationGong-kuang zidonghua1671-251X2020-05-01465768110.13272/j.issn.1671-251x.17504A mine-used frequency converter filter deviceRONG XiangSHI HanJIANG DezhiSUI XianmingWANG YueThe mine-used frequency converter is connected with motor through a long cable, and there is phenomenon of voltage reflection in transmission process of pulse width modulation(PWM) pulse, which causes spike voltage at the motor end and seriously affects operation reliability of frequency conversion driving system. At present, mine-used flame-proof frequency converter usually adopts series output reactor to suppress spike voltage, but suppression effect is limited. And the methods of suppressing spike voltage by using RC filter device and LRC filter device mainly aim at 380 V and 660 V frequency converter, which cannot meet requirement of suppressing spike voltage by 1 140 V frequency converter in underground coal mine. In view of the spike phenomenon caused by long-distance transmission of long cable, the effects of motor load, PWM rising time and cable length on the spike voltage in practical application were analyzed. The reflection coefficient of long cable terminal is not sensitive to change of motor load, and influence of motor load can be ignored in design process of filter parameters. The longer the rising time of PWM and the shorter the cable length, the smaller the spike voltage at the end of the motor.According to the above analysis, combined with cable length and device power loss, a design scheme of LRC filter device suitable for 1 140 V frequency converter in underground coal mine was proposed. Before PWM pulse signal is introduced into the long cable, the LRC filter device is used to delay PWM rising time, so as to achieve the purpose of suppressing spike voltage and high du/dt. Simulation and experimental results verify effectiveness of the filter device.http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.175041 140 v mine-used frequency converterfrequency conversion drivelrc filter devicelong cablespike voltagedu/dtpulse width modulatio |
spellingShingle | RONG Xiang SHI Han JIANG Dezhi SUI Xianming WANG Yue A mine-used frequency converter filter device Gong-kuang zidonghua 1 140 v mine-used frequency converter frequency conversion drive lrc filter device long cable spike voltage du/dt pulse width modulatio |
title | A mine-used frequency converter filter device |
title_full | A mine-used frequency converter filter device |
title_fullStr | A mine-used frequency converter filter device |
title_full_unstemmed | A mine-used frequency converter filter device |
title_short | A mine-used frequency converter filter device |
title_sort | mine used frequency converter filter device |
topic | 1 140 v mine-used frequency converter frequency conversion drive lrc filter device long cable spike voltage du/dt pulse width modulatio |
url | http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.17504 |
work_keys_str_mv | AT rongxiang amineusedfrequencyconverterfilterdevice AT shihan amineusedfrequencyconverterfilterdevice AT jiangdezhi amineusedfrequencyconverterfilterdevice AT suixianming amineusedfrequencyconverterfilterdevice AT wangyue amineusedfrequencyconverterfilterdevice AT rongxiang mineusedfrequencyconverterfilterdevice AT shihan mineusedfrequencyconverterfilterdevice AT jiangdezhi mineusedfrequencyconverterfilterdevice AT suixianming mineusedfrequencyconverterfilterdevice AT wangyue mineusedfrequencyconverterfilterdevice |