Reliability of five-minute vs. one-hour heart rate variability metrics in individuals with spinal cord injury

Background A previous study showed low reliability of 1-h HRV outcomes in participants with spinal cord injury (SCI), but it was not certain whether the low reliability was due to the unrestricted activity of participants. We aimed to investigate test-retest reliability of HRV metrics in individuals...

Full description

Bibliographic Details
Main Authors: Siriwipa Srirubkhwa, Lars Brockmann, Ratana Vichiansiri, Kenneth J. Hunt, Jittima Saengsuwan
Format: Article
Language:English
Published: PeerJ Inc. 2023-12-01
Series:PeerJ
Subjects:
Online Access:https://peerj.com/articles/16564.pdf
_version_ 1797384711296778240
author Siriwipa Srirubkhwa
Lars Brockmann
Ratana Vichiansiri
Kenneth J. Hunt
Jittima Saengsuwan
author_facet Siriwipa Srirubkhwa
Lars Brockmann
Ratana Vichiansiri
Kenneth J. Hunt
Jittima Saengsuwan
author_sort Siriwipa Srirubkhwa
collection DOAJ
description Background A previous study showed low reliability of 1-h HRV outcomes in participants with spinal cord injury (SCI), but it was not certain whether the low reliability was due to the unrestricted activity of participants. We aimed to investigate test-retest reliability of HRV metrics in individuals with SCI using a 1-h measurement in a supine position. Methods Individuals with SCI underwent two sessions of 1-h recording of the time between consecutive R waves (RR-intervals) in a supine position. HRV outcomes were obtained from a single 5-min data segment and for the full 1-h recording. HRV parameters of interest were: standard deviation of all normal-to-normal R-R intervals (SDNN) and square root of the mean of the squared differences between successive R-R intervals (RMSSD) (time domain); and high frequency power (HF), low frequency power (LF), very low frequency power (VLF), ultra-low frequency power (ULF) and total power (TP) (frequency domain). Relative reliability was assessed by intraclass correlation coefficient (ICC). Absolute reliability was assessed by coefficient of variation (CV) and Bland-Altman limits of agreement (LoA). Results Data from 37 individuals (14 with tetraplegia and 23 with paraplegia) were included. Relative reliability was higher for the 1-h (ICCs ranged from 0.13–0.71) than for the 5-min duration (ICCs ranged from 0.06–0.50) in the overall SCI group for all HRV metrics. Participants with tetraplegia had lower relative reliability compared to participants with paraplegia in all HRV metrics for the 5-min duration (ICCs ranged from −0.01–0.34 vs. 0.21–0.57). For the 1-h duration, participants with paraplegia showed higher relative reliability than participants with tetraplegia in all HRV metrics (ICCs ranged from 0.18–0.79 vs. 0.07–0.54) except TP (ICC 0.69 vs. 0.82). In terms of absolute reliability, the CVs and LoAs for the 1-h duration were better than for the 5-min duration. In general, time domain metrics showed better reliability than frequency domain metrics for both durations in participants with tetraplegia and paraplegia. The lowest CV and narrowest 95% LoA were found for SDNN in 5-min and 1-h durations overall and in both lesion levels. Conclusions The supine position did not provide better reliability compared to unrestricted activity in participants with SCI. HRV analysis using a 5-min duration is of limited value in SCI due to poor reliability. For the 1-h analysis duration, interpretation of the reliability of HRV varies according to lesion level: it is recommended to take lesion level into account when interpreting reliability measures.
first_indexed 2024-03-08T21:39:38Z
format Article
id doaj.art-eee89e23a9b64d44aff2353939f5ed1e
institution Directory Open Access Journal
issn 2167-8359
language English
last_indexed 2024-03-08T21:39:38Z
publishDate 2023-12-01
publisher PeerJ Inc.
record_format Article
series PeerJ
spelling doaj.art-eee89e23a9b64d44aff2353939f5ed1e2023-12-20T15:05:11ZengPeerJ Inc.PeerJ2167-83592023-12-0111e1656410.7717/peerj.16564Reliability of five-minute vs. one-hour heart rate variability metrics in individuals with spinal cord injurySiriwipa Srirubkhwa0Lars Brockmann1Ratana Vichiansiri2Kenneth J. Hunt3Jittima Saengsuwan4Department of Rehabilitation Medicine, Faculty of Medicine, Khon Kaen University, Khon Kaen, ThailandThe Laboratory for Rehabilitation Engineering, Institute for Human Centred Engineering, Bern University of Applied Sciences, Biel, SwitzerlandDepartment of Rehabilitation Medicine, Faculty of Medicine, Khon Kaen University, Khon Kaen, ThailandThe Laboratory for Rehabilitation Engineering, Institute for Human Centred Engineering, Bern University of Applied Sciences, Biel, SwitzerlandDepartment of Rehabilitation Medicine, Faculty of Medicine, Khon Kaen University, Khon Kaen, ThailandBackground A previous study showed low reliability of 1-h HRV outcomes in participants with spinal cord injury (SCI), but it was not certain whether the low reliability was due to the unrestricted activity of participants. We aimed to investigate test-retest reliability of HRV metrics in individuals with SCI using a 1-h measurement in a supine position. Methods Individuals with SCI underwent two sessions of 1-h recording of the time between consecutive R waves (RR-intervals) in a supine position. HRV outcomes were obtained from a single 5-min data segment and for the full 1-h recording. HRV parameters of interest were: standard deviation of all normal-to-normal R-R intervals (SDNN) and square root of the mean of the squared differences between successive R-R intervals (RMSSD) (time domain); and high frequency power (HF), low frequency power (LF), very low frequency power (VLF), ultra-low frequency power (ULF) and total power (TP) (frequency domain). Relative reliability was assessed by intraclass correlation coefficient (ICC). Absolute reliability was assessed by coefficient of variation (CV) and Bland-Altman limits of agreement (LoA). Results Data from 37 individuals (14 with tetraplegia and 23 with paraplegia) were included. Relative reliability was higher for the 1-h (ICCs ranged from 0.13–0.71) than for the 5-min duration (ICCs ranged from 0.06–0.50) in the overall SCI group for all HRV metrics. Participants with tetraplegia had lower relative reliability compared to participants with paraplegia in all HRV metrics for the 5-min duration (ICCs ranged from −0.01–0.34 vs. 0.21–0.57). For the 1-h duration, participants with paraplegia showed higher relative reliability than participants with tetraplegia in all HRV metrics (ICCs ranged from 0.18–0.79 vs. 0.07–0.54) except TP (ICC 0.69 vs. 0.82). In terms of absolute reliability, the CVs and LoAs for the 1-h duration were better than for the 5-min duration. In general, time domain metrics showed better reliability than frequency domain metrics for both durations in participants with tetraplegia and paraplegia. The lowest CV and narrowest 95% LoA were found for SDNN in 5-min and 1-h durations overall and in both lesion levels. Conclusions The supine position did not provide better reliability compared to unrestricted activity in participants with SCI. HRV analysis using a 5-min duration is of limited value in SCI due to poor reliability. For the 1-h analysis duration, interpretation of the reliability of HRV varies according to lesion level: it is recommended to take lesion level into account when interpreting reliability measures.https://peerj.com/articles/16564.pdfHeart rate variabilityTest-retest reliabilitySpinal cord injury
spellingShingle Siriwipa Srirubkhwa
Lars Brockmann
Ratana Vichiansiri
Kenneth J. Hunt
Jittima Saengsuwan
Reliability of five-minute vs. one-hour heart rate variability metrics in individuals with spinal cord injury
PeerJ
Heart rate variability
Test-retest reliability
Spinal cord injury
title Reliability of five-minute vs. one-hour heart rate variability metrics in individuals with spinal cord injury
title_full Reliability of five-minute vs. one-hour heart rate variability metrics in individuals with spinal cord injury
title_fullStr Reliability of five-minute vs. one-hour heart rate variability metrics in individuals with spinal cord injury
title_full_unstemmed Reliability of five-minute vs. one-hour heart rate variability metrics in individuals with spinal cord injury
title_short Reliability of five-minute vs. one-hour heart rate variability metrics in individuals with spinal cord injury
title_sort reliability of five minute vs one hour heart rate variability metrics in individuals with spinal cord injury
topic Heart rate variability
Test-retest reliability
Spinal cord injury
url https://peerj.com/articles/16564.pdf
work_keys_str_mv AT siriwipasrirubkhwa reliabilityoffiveminutevsonehourheartratevariabilitymetricsinindividualswithspinalcordinjury
AT larsbrockmann reliabilityoffiveminutevsonehourheartratevariabilitymetricsinindividualswithspinalcordinjury
AT ratanavichiansiri reliabilityoffiveminutevsonehourheartratevariabilitymetricsinindividualswithspinalcordinjury
AT kennethjhunt reliabilityoffiveminutevsonehourheartratevariabilitymetricsinindividualswithspinalcordinjury
AT jittimasaengsuwan reliabilityoffiveminutevsonehourheartratevariabilitymetricsinindividualswithspinalcordinjury