Performance evaluation of a rectifier column using gamma column scanning

Rectifier columns are considered to be a critical component in petroleum refineries and petrochemical processing installations as they are able to affect the overall performance of these facilities. It is deemed necessary to monitor the operational conditions of such vessels to optimize processes an...

Full description

Bibliographic Details
Main Authors: Aquino Denis D., Mallillin Janice P., Sulit Ramoncito F., Hila Frederick C., Nuñez Ivy Angelica A., Bulos Adelina D. M.
Format: Article
Language:English
Published: Sciendo 2017-12-01
Series:Nukleonika
Subjects:
Online Access:https://doi.org/10.1515/nuka-2017-0041
_version_ 1828425552987422720
author Aquino Denis D.
Mallillin Janice P.
Sulit Ramoncito F.
Hila Frederick C.
Nuñez Ivy Angelica A.
Bulos Adelina D. M.
author_facet Aquino Denis D.
Mallillin Janice P.
Sulit Ramoncito F.
Hila Frederick C.
Nuñez Ivy Angelica A.
Bulos Adelina D. M.
author_sort Aquino Denis D.
collection DOAJ
description Rectifier columns are considered to be a critical component in petroleum refineries and petrochemical processing installations as they are able to affect the overall performance of these facilities. It is deemed necessary to monitor the operational conditions of such vessels to optimize processes and prevent anomalies which could pose undesired consequences on product quality that might lead to huge financial losses. A rectifier column was subjected to gamma scanning using a 10-mCi Co-60 source and a 2-inch-long detector in tandem. Several scans were performed to gather information on the operating conditions of the column under different sets of operating parameters. The scan profiles revealed unexpected decreases in the radiation intensity at vapour levels between trays 2 and 3, and between trays 4 and 5. Flooding also occurred during several scans which could be attributed to parametric settings.
first_indexed 2024-12-10T16:32:26Z
format Article
id doaj.art-eefb03f0367d416e9cac1dbcf72a0928
institution Directory Open Access Journal
issn 0029-5922
language English
last_indexed 2024-12-10T16:32:26Z
publishDate 2017-12-01
publisher Sciendo
record_format Article
series Nukleonika
spelling doaj.art-eefb03f0367d416e9cac1dbcf72a09282022-12-22T01:41:31ZengSciendoNukleonika0029-59222017-12-0162428528710.1515/nuka-2017-0041nuka-2017-0041Performance evaluation of a rectifier column using gamma column scanningAquino Denis D.0Mallillin Janice P.1Sulit Ramoncito F.2Hila Frederick C.3Nuñez Ivy Angelica A.4Bulos Adelina D. M.5Philippine Nuclear Research Institute, Commonwealth Ave., Diliman, Quezon City, 1101 Metro Manila, Philippines, Tel.: +632 929 6011, Fax: +632 920 1646Philippine Nuclear Research Institute, Commonwealth Ave., Diliman, Quezon City, 1101 Metro Manila, Philippines, Tel.: +632 929 6011, Fax: +632 920 1646Philippine Nuclear Research Institute, Commonwealth Ave., Diliman, Quezon City, 1101 Metro Manila, Philippines, Tel.: +632 929 6011, Fax: +632 920 1646Philippine Nuclear Research Institute, Commonwealth Ave., Diliman, Quezon City, 1101 Metro Manila, Philippines, Tel.: +632 929 6011, Fax: +632 920 1646Philippine Nuclear Research Institute, Commonwealth Ave., Diliman, Quezon City, 1101 Metro Manila, Philippines, Tel.: +632 929 6011, Fax: +632 920 1646Philippine Nuclear Research Institute, Commonwealth Ave., Diliman, Quezon City, 1101 Metro Manila, Philippines, Tel.: +632 929 6011, Fax: +632 920 1646Rectifier columns are considered to be a critical component in petroleum refineries and petrochemical processing installations as they are able to affect the overall performance of these facilities. It is deemed necessary to monitor the operational conditions of such vessels to optimize processes and prevent anomalies which could pose undesired consequences on product quality that might lead to huge financial losses. A rectifier column was subjected to gamma scanning using a 10-mCi Co-60 source and a 2-inch-long detector in tandem. Several scans were performed to gather information on the operating conditions of the column under different sets of operating parameters. The scan profiles revealed unexpected decreases in the radiation intensity at vapour levels between trays 2 and 3, and between trays 4 and 5. Flooding also occurred during several scans which could be attributed to parametric settings.https://doi.org/10.1515/nuka-2017-0041gamma column scanningdistillation columndensity profileprocessing plantrefinery
spellingShingle Aquino Denis D.
Mallillin Janice P.
Sulit Ramoncito F.
Hila Frederick C.
Nuñez Ivy Angelica A.
Bulos Adelina D. M.
Performance evaluation of a rectifier column using gamma column scanning
Nukleonika
gamma column scanning
distillation column
density profile
processing plant
refinery
title Performance evaluation of a rectifier column using gamma column scanning
title_full Performance evaluation of a rectifier column using gamma column scanning
title_fullStr Performance evaluation of a rectifier column using gamma column scanning
title_full_unstemmed Performance evaluation of a rectifier column using gamma column scanning
title_short Performance evaluation of a rectifier column using gamma column scanning
title_sort performance evaluation of a rectifier column using gamma column scanning
topic gamma column scanning
distillation column
density profile
processing plant
refinery
url https://doi.org/10.1515/nuka-2017-0041
work_keys_str_mv AT aquinodenisd performanceevaluationofarectifiercolumnusinggammacolumnscanning
AT mallillinjanicep performanceevaluationofarectifiercolumnusinggammacolumnscanning
AT sulitramoncitof performanceevaluationofarectifiercolumnusinggammacolumnscanning
AT hilafrederickc performanceevaluationofarectifiercolumnusinggammacolumnscanning
AT nunezivyangelicaa performanceevaluationofarectifiercolumnusinggammacolumnscanning
AT bulosadelinadm performanceevaluationofarectifiercolumnusinggammacolumnscanning