Feasibility of the annulus fibrosus repair with in situ gelating hydrogels - A biomechanical study.

The surgical standard of care for lumbar discectomy leaves the annulus fibrosus (AF) defect unrepaired, despite considerable risk for a recurrent herniation. Identification of a viable defect repair strategy has until now been elusive. The scope of this ex vivo biomechanical study was to evaluate cr...

Full description

Bibliographic Details
Main Authors: Anne-Gita Scheibler, Tobias Götschi, Jonas Widmer, Claude Holenstein, Thomas Steffen, Roland S Camenzind, Jess G Snedeker, Mazda Farshad
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2018-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0208460
_version_ 1818833679059779584
author Anne-Gita Scheibler
Tobias Götschi
Jonas Widmer
Claude Holenstein
Thomas Steffen
Roland S Camenzind
Jess G Snedeker
Mazda Farshad
author_facet Anne-Gita Scheibler
Tobias Götschi
Jonas Widmer
Claude Holenstein
Thomas Steffen
Roland S Camenzind
Jess G Snedeker
Mazda Farshad
author_sort Anne-Gita Scheibler
collection DOAJ
description The surgical standard of care for lumbar discectomy leaves the annulus fibrosus (AF) defect unrepaired, despite considerable risk for a recurrent herniation. Identification of a viable defect repair strategy has until now been elusive. The scope of this ex vivo biomechanical study was to evaluate crosslinking hydrogels as potentially promising AF defect sealants, and provide a baseline for their use in combination with collagen scaffolds that restore disc volume. This study directly compared genipin crosslinked fibrin hydrogel (FibGen) as a promising preclinical candidate against a clinically available adhesive composed of glutaraldehyde and albumin (BioGlue). Forty-two bovine coccygeal functional spine units (FSU) were randomly allocated into four groups, namely untreated (control, n = 12), repaired with either one of the tested hydrogels (BioGlue, n = 12; FibGen, n = 12), or FibGen used in combination with a collagen hydrogel scaffold (FibGen+Scaffold, n = 6). All specimens underwent a moderate mechanical testing protocol in intact, injured and repaired states. After completion of the moderate testing protocol, the samples underwent a ramp-to-failure test. Lumbar discectomy destabilized the FSU as quantified by increased torsional range of motion (28.0° (19.1, 45.1) vs. 41.39° (27.3, 84.9), p<0.001), torsional neutral zone (3.1° (1.2, 7.7) vs. 4.8° (2.1, 12.1), Z = -3.49, p < 0.001), hysteresis(24.4 J (12.8, 76.0) vs. 27.6 J (16.4, 54.4), Z = -2.61, p = 0.009), with loss of both disc height (7.0 mm (5.0, 10.5) vs 6.1 mm (4.0, 9.3), Z = -5.16, p < 0.001) and torsional stiffness (0.76 Nmdeg-1 (0.38, 1.07) vs. 0.66 Nmdeg-1 (0.38, 0.97), Z = -3.98, p < 0.001). Most FibGen repaired AF endured the entire testing procedure whereas only a minority of BioGlue repaired AF and all FibGen+Scaffold repaired AF failed (6/10 vs. 3/12 vs. 0/6 respectively, p = 0.041). Both BioGlue and FibGen+Scaffold repaired AF partially restored disc height (0.47 mm (0.07, 2.41), p = 0.048 and 1.52 mm (0.41, 2.57), p = 0.021 respectively) compared to sham treatment (0.08 mm (-0.63, 0.88)) whereas FibGen-only repaired AF had no such effect (0.04 mm (-0.73, 1.13), U = 48.0, p = 1). The AF injury model demonstrated considerable change of FSU mechanics that could be partially restored by use of an AF sealant. While inclusion of a volumetric collagen scaffold led to repair failure, use of FibGen alone demonstrated clinically relevant promise for prevention of mechanical reherniation, outperforming an FDA approved sealant in this ex vivo test series.
first_indexed 2024-12-19T02:22:45Z
format Article
id doaj.art-ef18617bd42a4e55bc066332d8f3a28d
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-12-19T02:22:45Z
publishDate 2018-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-ef18617bd42a4e55bc066332d8f3a28d2022-12-21T20:40:06ZengPublic Library of Science (PLoS)PLoS ONE1932-62032018-01-011312e020846010.1371/journal.pone.0208460Feasibility of the annulus fibrosus repair with in situ gelating hydrogels - A biomechanical study.Anne-Gita ScheiblerTobias GötschiJonas WidmerClaude HolensteinThomas SteffenRoland S CamenzindJess G SnedekerMazda FarshadThe surgical standard of care for lumbar discectomy leaves the annulus fibrosus (AF) defect unrepaired, despite considerable risk for a recurrent herniation. Identification of a viable defect repair strategy has until now been elusive. The scope of this ex vivo biomechanical study was to evaluate crosslinking hydrogels as potentially promising AF defect sealants, and provide a baseline for their use in combination with collagen scaffolds that restore disc volume. This study directly compared genipin crosslinked fibrin hydrogel (FibGen) as a promising preclinical candidate against a clinically available adhesive composed of glutaraldehyde and albumin (BioGlue). Forty-two bovine coccygeal functional spine units (FSU) were randomly allocated into four groups, namely untreated (control, n = 12), repaired with either one of the tested hydrogels (BioGlue, n = 12; FibGen, n = 12), or FibGen used in combination with a collagen hydrogel scaffold (FibGen+Scaffold, n = 6). All specimens underwent a moderate mechanical testing protocol in intact, injured and repaired states. After completion of the moderate testing protocol, the samples underwent a ramp-to-failure test. Lumbar discectomy destabilized the FSU as quantified by increased torsional range of motion (28.0° (19.1, 45.1) vs. 41.39° (27.3, 84.9), p<0.001), torsional neutral zone (3.1° (1.2, 7.7) vs. 4.8° (2.1, 12.1), Z = -3.49, p < 0.001), hysteresis(24.4 J (12.8, 76.0) vs. 27.6 J (16.4, 54.4), Z = -2.61, p = 0.009), with loss of both disc height (7.0 mm (5.0, 10.5) vs 6.1 mm (4.0, 9.3), Z = -5.16, p < 0.001) and torsional stiffness (0.76 Nmdeg-1 (0.38, 1.07) vs. 0.66 Nmdeg-1 (0.38, 0.97), Z = -3.98, p < 0.001). Most FibGen repaired AF endured the entire testing procedure whereas only a minority of BioGlue repaired AF and all FibGen+Scaffold repaired AF failed (6/10 vs. 3/12 vs. 0/6 respectively, p = 0.041). Both BioGlue and FibGen+Scaffold repaired AF partially restored disc height (0.47 mm (0.07, 2.41), p = 0.048 and 1.52 mm (0.41, 2.57), p = 0.021 respectively) compared to sham treatment (0.08 mm (-0.63, 0.88)) whereas FibGen-only repaired AF had no such effect (0.04 mm (-0.73, 1.13), U = 48.0, p = 1). The AF injury model demonstrated considerable change of FSU mechanics that could be partially restored by use of an AF sealant. While inclusion of a volumetric collagen scaffold led to repair failure, use of FibGen alone demonstrated clinically relevant promise for prevention of mechanical reherniation, outperforming an FDA approved sealant in this ex vivo test series.https://doi.org/10.1371/journal.pone.0208460
spellingShingle Anne-Gita Scheibler
Tobias Götschi
Jonas Widmer
Claude Holenstein
Thomas Steffen
Roland S Camenzind
Jess G Snedeker
Mazda Farshad
Feasibility of the annulus fibrosus repair with in situ gelating hydrogels - A biomechanical study.
PLoS ONE
title Feasibility of the annulus fibrosus repair with in situ gelating hydrogels - A biomechanical study.
title_full Feasibility of the annulus fibrosus repair with in situ gelating hydrogels - A biomechanical study.
title_fullStr Feasibility of the annulus fibrosus repair with in situ gelating hydrogels - A biomechanical study.
title_full_unstemmed Feasibility of the annulus fibrosus repair with in situ gelating hydrogels - A biomechanical study.
title_short Feasibility of the annulus fibrosus repair with in situ gelating hydrogels - A biomechanical study.
title_sort feasibility of the annulus fibrosus repair with in situ gelating hydrogels a biomechanical study
url https://doi.org/10.1371/journal.pone.0208460
work_keys_str_mv AT annegitascheibler feasibilityoftheannulusfibrosusrepairwithinsitugelatinghydrogelsabiomechanicalstudy
AT tobiasgotschi feasibilityoftheannulusfibrosusrepairwithinsitugelatinghydrogelsabiomechanicalstudy
AT jonaswidmer feasibilityoftheannulusfibrosusrepairwithinsitugelatinghydrogelsabiomechanicalstudy
AT claudeholenstein feasibilityoftheannulusfibrosusrepairwithinsitugelatinghydrogelsabiomechanicalstudy
AT thomassteffen feasibilityoftheannulusfibrosusrepairwithinsitugelatinghydrogelsabiomechanicalstudy
AT rolandscamenzind feasibilityoftheannulusfibrosusrepairwithinsitugelatinghydrogelsabiomechanicalstudy
AT jessgsnedeker feasibilityoftheannulusfibrosusrepairwithinsitugelatinghydrogelsabiomechanicalstudy
AT mazdafarshad feasibilityoftheannulusfibrosusrepairwithinsitugelatinghydrogelsabiomechanicalstudy