A modified XY model of transformer oil–paper insulation system including non‐uniform aging and conductance effect

Abstract The accuracy and feasibility of the traditional XY model of transformer oil–paper insulation system are disputable since it ignored the effect of non‐uniform aging and conductance on dielectric response property. Given this issue, this work attempted to report a modified XY model to overcom...

Full description

Bibliographic Details
Main Authors: Xianhao Fan, Jiefeng Liu, Yiyi Zhang, Shichang Yang, Chaohai Zhang, Yubo Zhang
Format: Article
Language:English
Published: Wiley 2021-07-01
Series:IET Generation, Transmission & Distribution
Subjects:
Online Access:https://doi.org/10.1049/gtd2.12168
_version_ 1798002938079084544
author Xianhao Fan
Jiefeng Liu
Yiyi Zhang
Shichang Yang
Chaohai Zhang
Yubo Zhang
author_facet Xianhao Fan
Jiefeng Liu
Yiyi Zhang
Shichang Yang
Chaohai Zhang
Yubo Zhang
author_sort Xianhao Fan
collection DOAJ
description Abstract The accuracy and feasibility of the traditional XY model of transformer oil–paper insulation system are disputable since it ignored the effect of non‐uniform aging and conductance on dielectric response property. Given this issue, this work attempted to report a modified XY model to overcome these defects. The novelty of this work is in the exploration of the modified XY model as a potential tool for establishing the quantitative correlation among the complex relative permittivity of the liquid insulation, solid insulation, and liquid–solid composite insulation. In that respect, the presented verification experiments proved the feasibility and accuracy of the reported model. The contributions are expected to provide a theoretical basis for the condition evaluation of transformer solid insulation under non‐uniform aging conditions.
first_indexed 2024-04-11T12:00:15Z
format Article
id doaj.art-ef19710c7141460cb4c7139b56160000
institution Directory Open Access Journal
issn 1751-8687
1751-8695
language English
last_indexed 2024-04-11T12:00:15Z
publishDate 2021-07-01
publisher Wiley
record_format Article
series IET Generation, Transmission & Distribution
spelling doaj.art-ef19710c7141460cb4c7139b561600002022-12-22T04:24:54ZengWileyIET Generation, Transmission & Distribution1751-86871751-86952021-07-0115132008201710.1049/gtd2.12168A modified XY model of transformer oil–paper insulation system including non‐uniform aging and conductance effectXianhao Fan0Jiefeng Liu1Yiyi Zhang2Shichang Yang3Chaohai Zhang4Yubo Zhang5School of Electrical Engineering Guangxi University, Guangxi Nanning ChinaSchool of Electrical Engineering Guangxi University, Guangxi Nanning ChinaSchool of Electrical Engineering Guangxi University, Guangxi Nanning ChinaSchool of Electrical Engineering Guangxi University, Guangxi Nanning ChinaSchool of Electrical Engineering Guangxi University, Guangxi Nanning ChinaGuangxi Power Grid Corporation, Guangxi Electric Power Research Institute Nanning ChinaAbstract The accuracy and feasibility of the traditional XY model of transformer oil–paper insulation system are disputable since it ignored the effect of non‐uniform aging and conductance on dielectric response property. Given this issue, this work attempted to report a modified XY model to overcome these defects. The novelty of this work is in the exploration of the modified XY model as a potential tool for establishing the quantitative correlation among the complex relative permittivity of the liquid insulation, solid insulation, and liquid–solid composite insulation. In that respect, the presented verification experiments proved the feasibility and accuracy of the reported model. The contributions are expected to provide a theoretical basis for the condition evaluation of transformer solid insulation under non‐uniform aging conditions.https://doi.org/10.1049/gtd2.12168Dielectric permittivityOrganic insulationTransformers and reactors
spellingShingle Xianhao Fan
Jiefeng Liu
Yiyi Zhang
Shichang Yang
Chaohai Zhang
Yubo Zhang
A modified XY model of transformer oil–paper insulation system including non‐uniform aging and conductance effect
IET Generation, Transmission & Distribution
Dielectric permittivity
Organic insulation
Transformers and reactors
title A modified XY model of transformer oil–paper insulation system including non‐uniform aging and conductance effect
title_full A modified XY model of transformer oil–paper insulation system including non‐uniform aging and conductance effect
title_fullStr A modified XY model of transformer oil–paper insulation system including non‐uniform aging and conductance effect
title_full_unstemmed A modified XY model of transformer oil–paper insulation system including non‐uniform aging and conductance effect
title_short A modified XY model of transformer oil–paper insulation system including non‐uniform aging and conductance effect
title_sort modified xy model of transformer oil paper insulation system including non uniform aging and conductance effect
topic Dielectric permittivity
Organic insulation
Transformers and reactors
url https://doi.org/10.1049/gtd2.12168
work_keys_str_mv AT xianhaofan amodifiedxymodeloftransformeroilpaperinsulationsystemincludingnonuniformagingandconductanceeffect
AT jiefengliu amodifiedxymodeloftransformeroilpaperinsulationsystemincludingnonuniformagingandconductanceeffect
AT yiyizhang amodifiedxymodeloftransformeroilpaperinsulationsystemincludingnonuniformagingandconductanceeffect
AT shichangyang amodifiedxymodeloftransformeroilpaperinsulationsystemincludingnonuniformagingandconductanceeffect
AT chaohaizhang amodifiedxymodeloftransformeroilpaperinsulationsystemincludingnonuniformagingandconductanceeffect
AT yubozhang amodifiedxymodeloftransformeroilpaperinsulationsystemincludingnonuniformagingandconductanceeffect
AT xianhaofan modifiedxymodeloftransformeroilpaperinsulationsystemincludingnonuniformagingandconductanceeffect
AT jiefengliu modifiedxymodeloftransformeroilpaperinsulationsystemincludingnonuniformagingandconductanceeffect
AT yiyizhang modifiedxymodeloftransformeroilpaperinsulationsystemincludingnonuniformagingandconductanceeffect
AT shichangyang modifiedxymodeloftransformeroilpaperinsulationsystemincludingnonuniformagingandconductanceeffect
AT chaohaizhang modifiedxymodeloftransformeroilpaperinsulationsystemincludingnonuniformagingandconductanceeffect
AT yubozhang modifiedxymodeloftransformeroilpaperinsulationsystemincludingnonuniformagingandconductanceeffect