ACTIVE DISTURBANCE REJECTION CONTROL FOR STRUCTURE VIBRATION WITH ELECTROMAGNETIC INERTIAL ACTUATOR (MT)

For the problems of system model inaccuracy, internal and external disturbances in active vibration control of an all-clamped plate structure, an active vibration control method based on an active disturbance rejection controller(ADRC) was introduced to suppress the structural vibration by using ine...

Full description

Bibliographic Details
Main Authors: LU Lu, LI Jing, ZHANG LuYao, ZHU ChaoWei, LI ShengQuan
Format: Article
Language:zho
Published: Editorial Office of Journal of Mechanical Strength 2023-01-01
Series:Jixie qiangdu
Subjects:
Online Access:http://www.jxqd.net.cn/thesisDetails#10.16579/j.issn.1001.9669.2023.01.003
_version_ 1797767635082936320
author LU Lu
LI Jing
ZHANG LuYao
ZHU ChaoWei
LI ShengQuan
author_facet LU Lu
LI Jing
ZHANG LuYao
ZHU ChaoWei
LI ShengQuan
author_sort LU Lu
collection DOAJ
description For the problems of system model inaccuracy, internal and external disturbances in active vibration control of an all-clamped plate structure, an active vibration control method based on an active disturbance rejection controller(ADRC) was introduced to suppress the structural vibration by using inertial actuators, and the effect of the bandwidth of the controller observer, the parameters of PD controller, the gain of controller on control performance were also studied. First, a state space model was established to model the all-clamped plate structure with the inertial actuator. Then, the three-order linear extended state observer was used to estimate the uncertainties and state variables for the whole vibration control system. Additionally, the influence of each parameter of ADRC on the vibration control was also theoretically analyzed to achieve the excellent vibration suppression performance. Finally, based on NI-PCIe 6343 acquisition card, a hardware-in-the-loop experiment platform was set up in the desktop real-time of Matlab/Simulink to verify the vibration performances of ADRC and the accuracy of the theoretical analysis. The results show that the ADRC algorithm is feasible for vibration control. When other parameters of the controller remain unchanged, in a certain range, increasing the bandwidth of the controller observer or decreasing the gain of controller can improve the control performance, but adjusting the parameters of PD controller have little effect on the control performance.
first_indexed 2024-03-12T20:41:40Z
format Article
id doaj.art-ef5fdc79c792431e94037f212f68d1c7
institution Directory Open Access Journal
issn 1001-9669
language zho
last_indexed 2024-03-12T20:41:40Z
publishDate 2023-01-01
publisher Editorial Office of Journal of Mechanical Strength
record_format Article
series Jixie qiangdu
spelling doaj.art-ef5fdc79c792431e94037f212f68d1c72023-08-01T07:55:16ZzhoEditorial Office of Journal of Mechanical StrengthJixie qiangdu1001-96692023-01-01162536351165ACTIVE DISTURBANCE REJECTION CONTROL FOR STRUCTURE VIBRATION WITH ELECTROMAGNETIC INERTIAL ACTUATOR (MT)LU LuLI JingZHANG LuYaoZHU ChaoWeiLI ShengQuanFor the problems of system model inaccuracy, internal and external disturbances in active vibration control of an all-clamped plate structure, an active vibration control method based on an active disturbance rejection controller(ADRC) was introduced to suppress the structural vibration by using inertial actuators, and the effect of the bandwidth of the controller observer, the parameters of PD controller, the gain of controller on control performance were also studied. First, a state space model was established to model the all-clamped plate structure with the inertial actuator. Then, the three-order linear extended state observer was used to estimate the uncertainties and state variables for the whole vibration control system. Additionally, the influence of each parameter of ADRC on the vibration control was also theoretically analyzed to achieve the excellent vibration suppression performance. Finally, based on NI-PCIe 6343 acquisition card, a hardware-in-the-loop experiment platform was set up in the desktop real-time of Matlab/Simulink to verify the vibration performances of ADRC and the accuracy of the theoretical analysis. The results show that the ADRC algorithm is feasible for vibration control. When other parameters of the controller remain unchanged, in a certain range, increasing the bandwidth of the controller observer or decreasing the gain of controller can improve the control performance, but adjusting the parameters of PD controller have little effect on the control performance.http://www.jxqd.net.cn/thesisDetails#10.16579/j.issn.1001.9669.2023.01.003Inertial actuator;All-clamped plates;Active vibration control;Active disturbance rejection control
spellingShingle LU Lu
LI Jing
ZHANG LuYao
ZHU ChaoWei
LI ShengQuan
ACTIVE DISTURBANCE REJECTION CONTROL FOR STRUCTURE VIBRATION WITH ELECTROMAGNETIC INERTIAL ACTUATOR (MT)
Jixie qiangdu
Inertial actuator;All-clamped plates;Active vibration control;Active disturbance rejection control
title ACTIVE DISTURBANCE REJECTION CONTROL FOR STRUCTURE VIBRATION WITH ELECTROMAGNETIC INERTIAL ACTUATOR (MT)
title_full ACTIVE DISTURBANCE REJECTION CONTROL FOR STRUCTURE VIBRATION WITH ELECTROMAGNETIC INERTIAL ACTUATOR (MT)
title_fullStr ACTIVE DISTURBANCE REJECTION CONTROL FOR STRUCTURE VIBRATION WITH ELECTROMAGNETIC INERTIAL ACTUATOR (MT)
title_full_unstemmed ACTIVE DISTURBANCE REJECTION CONTROL FOR STRUCTURE VIBRATION WITH ELECTROMAGNETIC INERTIAL ACTUATOR (MT)
title_short ACTIVE DISTURBANCE REJECTION CONTROL FOR STRUCTURE VIBRATION WITH ELECTROMAGNETIC INERTIAL ACTUATOR (MT)
title_sort active disturbance rejection control for structure vibration with electromagnetic inertial actuator mt
topic Inertial actuator;All-clamped plates;Active vibration control;Active disturbance rejection control
url http://www.jxqd.net.cn/thesisDetails#10.16579/j.issn.1001.9669.2023.01.003
work_keys_str_mv AT lulu activedisturbancerejectioncontrolforstructurevibrationwithelectromagneticinertialactuatormt
AT lijing activedisturbancerejectioncontrolforstructurevibrationwithelectromagneticinertialactuatormt
AT zhangluyao activedisturbancerejectioncontrolforstructurevibrationwithelectromagneticinertialactuatormt
AT zhuchaowei activedisturbancerejectioncontrolforstructurevibrationwithelectromagneticinertialactuatormt
AT lishengquan activedisturbancerejectioncontrolforstructurevibrationwithelectromagneticinertialactuatormt