A Study on Changes of Window Thermal Performance by Analysis of Physical Test Results in Korea

The interest in zero energy buildings is increasing in South Korea. Zero energy buildings need to save energy by using passive technology. The window performance is important to the thermal insulation of the building. Also, the government regulates the window performance through regulation and stand...

Full description

Bibliographic Details
Main Authors: Seok-Hyun Kim, Hakgeun Jeong, Soo Cho
Format: Article
Language:English
Published: MDPI AG 2019-10-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/12/20/3822
_version_ 1817990191928836096
author Seok-Hyun Kim
Hakgeun Jeong
Soo Cho
author_facet Seok-Hyun Kim
Hakgeun Jeong
Soo Cho
author_sort Seok-Hyun Kim
collection DOAJ
description The interest in zero energy buildings is increasing in South Korea. Zero energy buildings need to save energy by using passive technology. The window performance is important to the thermal insulation of the building. Also, the government regulates the window performance through regulation and standards. However, it is difficult to predict window performance because the components of the window have become complicated due to the various materials used in the glass and frame. Based on window performance standards and regulations, the quality of window performance was managed. In this research, to consider thermal performance in proper window design in South Korea, we confirmed the impact on the thermal performance of the window through various kinds of materials and shapes. The authors also propose a window shape classification and frame calculation method based on actual test results. The authors analyzed the thermal performance data of the windows provided by the Korea Energy Agency and confirmed the change in the thermal performance of the windows by year and by frame material. The average U-value of the window decreased from 2012 to 2015 and maintained similar values until 2017. In 2018, this value was decreased to comply. Also, the authors confirmed the U-value of the windows through actual physical experiments and confirmed the change in thermal performance by the construction of the windows based on the results. The results show, in the case of aluminum windows, the U-value corresponding to Grade 3 (1.4&#8722;2.1 W/m<sup>2</sup>&#183;K) was as high as about 60%. Regarding the analyzed results of the U-values of PVC windows, Grade 3 (U-value of 1.4&#8722;2.1 W/m<sup>2</sup>&#183;K) accounted for about 35%, and Grade 2 (U-value of 1.0&#8722;1.4 W/m<sup>2</sup>&#183;K) for about 29%. This paper also confirmed that the frame U-value of the PVC windows is lower than the frame U-value of the aluminum windows. Therefore, the authors proposed the performance index of the glazing part in PVC and aluminum window design. The results of this research can be used as basic data to identify problems in the method of determining the performance of windows in Korea.
first_indexed 2024-04-14T00:56:48Z
format Article
id doaj.art-ef699d6e6d034b5292e7d5927ae7172c
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-04-14T00:56:48Z
publishDate 2019-10-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-ef699d6e6d034b5292e7d5927ae7172c2022-12-22T02:21:36ZengMDPI AGEnergies1996-10732019-10-011220382210.3390/en12203822en12203822A Study on Changes of Window Thermal Performance by Analysis of Physical Test Results in KoreaSeok-Hyun Kim0Hakgeun Jeong1Soo Cho2Energy ICT∙ESS Laboratory, Korea Institute of Energy Research, Daejeon 34101, KoreaEnergy ICT∙ESS Laboratory, Korea Institute of Energy Research, Daejeon 34101, KoreaEnergy ICT∙ESS Laboratory, Korea Institute of Energy Research, Daejeon 34101, KoreaThe interest in zero energy buildings is increasing in South Korea. Zero energy buildings need to save energy by using passive technology. The window performance is important to the thermal insulation of the building. Also, the government regulates the window performance through regulation and standards. However, it is difficult to predict window performance because the components of the window have become complicated due to the various materials used in the glass and frame. Based on window performance standards and regulations, the quality of window performance was managed. In this research, to consider thermal performance in proper window design in South Korea, we confirmed the impact on the thermal performance of the window through various kinds of materials and shapes. The authors also propose a window shape classification and frame calculation method based on actual test results. The authors analyzed the thermal performance data of the windows provided by the Korea Energy Agency and confirmed the change in the thermal performance of the windows by year and by frame material. The average U-value of the window decreased from 2012 to 2015 and maintained similar values until 2017. In 2018, this value was decreased to comply. Also, the authors confirmed the U-value of the windows through actual physical experiments and confirmed the change in thermal performance by the construction of the windows based on the results. The results show, in the case of aluminum windows, the U-value corresponding to Grade 3 (1.4&#8722;2.1 W/m<sup>2</sup>&#183;K) was as high as about 60%. Regarding the analyzed results of the U-values of PVC windows, Grade 3 (U-value of 1.4&#8722;2.1 W/m<sup>2</sup>&#183;K) accounted for about 35%, and Grade 2 (U-value of 1.0&#8722;1.4 W/m<sup>2</sup>&#183;K) for about 29%. This paper also confirmed that the frame U-value of the PVC windows is lower than the frame U-value of the aluminum windows. Therefore, the authors proposed the performance index of the glazing part in PVC and aluminum window design. The results of this research can be used as basic data to identify problems in the method of determining the performance of windows in Korea.https://www.mdpi.com/1996-1073/12/20/3822window thermal performanceu-valuewindow typesimulation performance testactual physical performance test
spellingShingle Seok-Hyun Kim
Hakgeun Jeong
Soo Cho
A Study on Changes of Window Thermal Performance by Analysis of Physical Test Results in Korea
Energies
window thermal performance
u-value
window type
simulation performance test
actual physical performance test
title A Study on Changes of Window Thermal Performance by Analysis of Physical Test Results in Korea
title_full A Study on Changes of Window Thermal Performance by Analysis of Physical Test Results in Korea
title_fullStr A Study on Changes of Window Thermal Performance by Analysis of Physical Test Results in Korea
title_full_unstemmed A Study on Changes of Window Thermal Performance by Analysis of Physical Test Results in Korea
title_short A Study on Changes of Window Thermal Performance by Analysis of Physical Test Results in Korea
title_sort study on changes of window thermal performance by analysis of physical test results in korea
topic window thermal performance
u-value
window type
simulation performance test
actual physical performance test
url https://www.mdpi.com/1996-1073/12/20/3822
work_keys_str_mv AT seokhyunkim astudyonchangesofwindowthermalperformancebyanalysisofphysicaltestresultsinkorea
AT hakgeunjeong astudyonchangesofwindowthermalperformancebyanalysisofphysicaltestresultsinkorea
AT soocho astudyonchangesofwindowthermalperformancebyanalysisofphysicaltestresultsinkorea
AT seokhyunkim studyonchangesofwindowthermalperformancebyanalysisofphysicaltestresultsinkorea
AT hakgeunjeong studyonchangesofwindowthermalperformancebyanalysisofphysicaltestresultsinkorea
AT soocho studyonchangesofwindowthermalperformancebyanalysisofphysicaltestresultsinkorea