Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: a validation study Hemoglobina medida por Hemocue y por un método de referencia en sangre venosa y capilar: estudio de validación
Objective. To assess the comparability of hemoglobin concentration (Hb) in venous and capillary blood measured by Hemocue and an automated spectrophotometer (Celldyn) and to document the influence of type of blood (capillary or venous) and analysis method on anemia prevalence estimates. Material and...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Instituto Nacional de Salud Pública
2002-06-01
|
Series: | Salud Pública de México |
Subjects: | |
Online Access: | http://www.scielo.org.mx/scielo.php?script=sci_arttext&pid=S0036-36342002000300005 |
_version_ | 1818493742549565440 |
---|---|
author | Lynnette Neufeld Armando García-Guerra Domingo Sánchez-Francia Oscar Newton-Sánchez María Dolores Ramírez-Villalobos Juan Rivera-Dommarco |
author_facet | Lynnette Neufeld Armando García-Guerra Domingo Sánchez-Francia Oscar Newton-Sánchez María Dolores Ramírez-Villalobos Juan Rivera-Dommarco |
author_sort | Lynnette Neufeld |
collection | DOAJ |
description | Objective. To assess the comparability of hemoglobin concentration (Hb) in venous and capillary blood measured by Hemocue and an automated spectrophotometer (Celldyn) and to document the influence of type of blood (capillary or venous) and analysis method on anemia prevalence estimates. Material and Methods. Between February and May 2000, capillary and venous samples were collected from 72 adults and children at Hospital del Niño Morelense (Morelos State Children's Hospital) in Cuernavaca, Morelos, Mexico, and assessed for Hb using the Hemocue and Celldyn methods. Estimated Hb levels were compared using the concordance correlation coefficient and Student's t test for paired data. The sensitivity and specificity for anemia diagnosis were estimated and compared between type of blood and method of assessment. Results. Capillary blood had higher Hb (+0.5g/dl) than venous blood in adults and children, as did samples assessed by Celldyn compared to Hemocue (+0.3g/dl). Specificity to detect anemia was adequate (>0.90) but sensitivity was low for capillary blood assessed by Hemocue (<0.80). Conclusions. The difference in Hb between venous and capillary blood is likely related to biological variability. Hemoglobin concentration in capillary blood assessed by Hemocue provides an adequate estimation of population anemia prevalence but may result in excess false negative diagnoses among individuals. The results of this study stress the importance of sample collection technique, particularly for children. Method of analysis and sampling site need to be taken into consideration in field studies.<br>Objetivo. Evaluar la comparabilidad de la concentración de hemoglobina (Hb) en sangre venosa y capilar medida por Hemocue y por espectrofotómetro automatizado (Celldyn), así como documentar la influencia del tipo de sangre (capilar o venosa) y del método de análisis sobre la prevalencia de anemia. Material y métodos. De febrero a mayo de 2000, se recolectaron muestras de sangre capilar y venosa en 72 adultos y niños en el Hospital del Niño Morelense, Cuernavaca, Morelos, México. Se determinaron los niveles de Hb con los métodos Hemocue y Celldyn. Las cifras de Hb estimadas se compararon con el coeficiente de concordancia y la prueba pareada de t de Student. También se comparó la sensibilidad y especificidad para el diagnóstico de anemia, utilizando sangre de los dos tipos y métodos de análisis. Resultados. La Hb fue mayor en sangre capilar comparada con sangre venosa (+0.5g/dl) en adultos y niños, y en las determinaciones por Celldyn comparadas con las de Hemocue (+0.3 g/dl). La especificidad para el diagnóstico de anemia fue adecuada (>0.90), mientras que la sensibilidad fue baja para las muestras capilares medidas por Hemocue (<0.80). Conclusiones. Es probable que la diferencia en la Hb entre sangre venosa y capilar refleje variabilidad biológica. La Hb en sangre capilar medida por Hemocue provee una estimación adecuada de la prevalencia de anemia en poblaciones, pero podría resultar en un exceso de diagnósticos falsos negativos. Los resultados de este estudio ponen énfasis en la importancia de la técnica de recolección de la muestra, particularmente en niños. Los métodos de análisis y tipos de muestra de sangre deben ser tomados en cuenta en estudios de campo. |
first_indexed | 2024-12-10T17:57:59Z |
format | Article |
id | doaj.art-ef91298767ad445ba24a4740b57984e6 |
institution | Directory Open Access Journal |
issn | 0036-3634 |
language | English |
last_indexed | 2024-12-10T17:57:59Z |
publishDate | 2002-06-01 |
publisher | Instituto Nacional de Salud Pública |
record_format | Article |
series | Salud Pública de México |
spelling | doaj.art-ef91298767ad445ba24a4740b57984e62022-12-22T01:38:52ZengInstituto Nacional de Salud PúblicaSalud Pública de México0036-36342002-06-01443219227Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: a validation study Hemoglobina medida por Hemocue y por un método de referencia en sangre venosa y capilar: estudio de validaciónLynnette NeufeldArmando García-GuerraDomingo Sánchez-FranciaOscar Newton-SánchezMaría Dolores Ramírez-VillalobosJuan Rivera-DommarcoObjective. To assess the comparability of hemoglobin concentration (Hb) in venous and capillary blood measured by Hemocue and an automated spectrophotometer (Celldyn) and to document the influence of type of blood (capillary or venous) and analysis method on anemia prevalence estimates. Material and Methods. Between February and May 2000, capillary and venous samples were collected from 72 adults and children at Hospital del Niño Morelense (Morelos State Children's Hospital) in Cuernavaca, Morelos, Mexico, and assessed for Hb using the Hemocue and Celldyn methods. Estimated Hb levels were compared using the concordance correlation coefficient and Student's t test for paired data. The sensitivity and specificity for anemia diagnosis were estimated and compared between type of blood and method of assessment. Results. Capillary blood had higher Hb (+0.5g/dl) than venous blood in adults and children, as did samples assessed by Celldyn compared to Hemocue (+0.3g/dl). Specificity to detect anemia was adequate (>0.90) but sensitivity was low for capillary blood assessed by Hemocue (<0.80). Conclusions. The difference in Hb between venous and capillary blood is likely related to biological variability. Hemoglobin concentration in capillary blood assessed by Hemocue provides an adequate estimation of population anemia prevalence but may result in excess false negative diagnoses among individuals. The results of this study stress the importance of sample collection technique, particularly for children. Method of analysis and sampling site need to be taken into consideration in field studies.<br>Objetivo. Evaluar la comparabilidad de la concentración de hemoglobina (Hb) en sangre venosa y capilar medida por Hemocue y por espectrofotómetro automatizado (Celldyn), así como documentar la influencia del tipo de sangre (capilar o venosa) y del método de análisis sobre la prevalencia de anemia. Material y métodos. De febrero a mayo de 2000, se recolectaron muestras de sangre capilar y venosa en 72 adultos y niños en el Hospital del Niño Morelense, Cuernavaca, Morelos, México. Se determinaron los niveles de Hb con los métodos Hemocue y Celldyn. Las cifras de Hb estimadas se compararon con el coeficiente de concordancia y la prueba pareada de t de Student. También se comparó la sensibilidad y especificidad para el diagnóstico de anemia, utilizando sangre de los dos tipos y métodos de análisis. Resultados. La Hb fue mayor en sangre capilar comparada con sangre venosa (+0.5g/dl) en adultos y niños, y en las determinaciones por Celldyn comparadas con las de Hemocue (+0.3 g/dl). La especificidad para el diagnóstico de anemia fue adecuada (>0.90), mientras que la sensibilidad fue baja para las muestras capilares medidas por Hemocue (<0.80). Conclusiones. Es probable que la diferencia en la Hb entre sangre venosa y capilar refleje variabilidad biológica. La Hb en sangre capilar medida por Hemocue provee una estimación adecuada de la prevalencia de anemia en poblaciones, pero podría resultar en un exceso de diagnósticos falsos negativos. Los resultados de este estudio ponen énfasis en la importancia de la técnica de recolección de la muestra, particularmente en niños. Los métodos de análisis y tipos de muestra de sangre deben ser tomados en cuenta en estudios de campo.http://www.scielo.org.mx/scielo.php?script=sci_arttext&pid=S0036-36342002000300005hemoglobinaHemocueCelldynmétodos de referenciasangre capilarsangre venosaanemiaMéxicohemoglobinHemocueCelldynreference methodscapillary bloodvenous bloodanemia prevalenceMexico |
spellingShingle | Lynnette Neufeld Armando García-Guerra Domingo Sánchez-Francia Oscar Newton-Sánchez María Dolores Ramírez-Villalobos Juan Rivera-Dommarco Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: a validation study Hemoglobina medida por Hemocue y por un método de referencia en sangre venosa y capilar: estudio de validación Salud Pública de México hemoglobina Hemocue Celldyn métodos de referencia sangre capilar sangre venosa anemia México hemoglobin Hemocue Celldyn reference methods capillary blood venous blood anemia prevalence Mexico |
title | Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: a validation study Hemoglobina medida por Hemocue y por un método de referencia en sangre venosa y capilar: estudio de validación |
title_full | Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: a validation study Hemoglobina medida por Hemocue y por un método de referencia en sangre venosa y capilar: estudio de validación |
title_fullStr | Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: a validation study Hemoglobina medida por Hemocue y por un método de referencia en sangre venosa y capilar: estudio de validación |
title_full_unstemmed | Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: a validation study Hemoglobina medida por Hemocue y por un método de referencia en sangre venosa y capilar: estudio de validación |
title_short | Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: a validation study Hemoglobina medida por Hemocue y por un método de referencia en sangre venosa y capilar: estudio de validación |
title_sort | hemoglobin measured by hemocue and a reference method in venous and capillary blood a validation study hemoglobina medida por hemocue y por un metodo de referencia en sangre venosa y capilar estudio de validacion |
topic | hemoglobina Hemocue Celldyn métodos de referencia sangre capilar sangre venosa anemia México hemoglobin Hemocue Celldyn reference methods capillary blood venous blood anemia prevalence Mexico |
url | http://www.scielo.org.mx/scielo.php?script=sci_arttext&pid=S0036-36342002000300005 |
work_keys_str_mv | AT lynnetteneufeld hemoglobinmeasuredbyhemocueandareferencemethodinvenousandcapillarybloodavalidationstudyhemoglobinamedidaporhemocueyporunmetododereferenciaensangrevenosaycapilarestudiodevalidacion AT armandogarciaguerra hemoglobinmeasuredbyhemocueandareferencemethodinvenousandcapillarybloodavalidationstudyhemoglobinamedidaporhemocueyporunmetododereferenciaensangrevenosaycapilarestudiodevalidacion AT domingosanchezfrancia hemoglobinmeasuredbyhemocueandareferencemethodinvenousandcapillarybloodavalidationstudyhemoglobinamedidaporhemocueyporunmetododereferenciaensangrevenosaycapilarestudiodevalidacion AT oscarnewtonsanchez hemoglobinmeasuredbyhemocueandareferencemethodinvenousandcapillarybloodavalidationstudyhemoglobinamedidaporhemocueyporunmetododereferenciaensangrevenosaycapilarestudiodevalidacion AT mariadoloresramirezvillalobos hemoglobinmeasuredbyhemocueandareferencemethodinvenousandcapillarybloodavalidationstudyhemoglobinamedidaporhemocueyporunmetododereferenciaensangrevenosaycapilarestudiodevalidacion AT juanriveradommarco hemoglobinmeasuredbyhemocueandareferencemethodinvenousandcapillarybloodavalidationstudyhemoglobinamedidaporhemocueyporunmetododereferenciaensangrevenosaycapilarestudiodevalidacion |