Percutaneous Secundum Atrial Septal Defect Closure: Failure Rate and Procedural Predictors

Background: Percutaneous atrial septal defect (ASD) closure is one of therapeutic options for patients with a suitable ASD anatomy, however in developing countries, the exact figure and procedural characteristics remain unknown. Therefore, this study was conducted to identify the failure rate and pr...

Full description

Bibliographic Details
Main Authors: Elien Yuwono, Eka Gunawijaya, Ni Putu Veny Kartika Yantie
Format: Article
Language:English
Published: Cell and BioPharmaceutical Institute 2024-03-01
Series:MCBS (Molecular and Cellular Biomedical Sciences)
Online Access:https://cellbiopharm.com/ojs/index.php/MCBS/article/view/442
_version_ 1797246898658082816
author Elien Yuwono
Eka Gunawijaya
Ni Putu Veny Kartika Yantie
author_facet Elien Yuwono
Eka Gunawijaya
Ni Putu Veny Kartika Yantie
author_sort Elien Yuwono
collection DOAJ
description Background: Percutaneous atrial septal defect (ASD) closure is one of therapeutic options for patients with a suitable ASD anatomy, however in developing countries, the exact figure and procedural characteristics remain unknown. Therefore, this study was conducted to identify the failure rate and procedural predictors of the percutaneous ASD closure. Materials and methods: A retrospective study using a database of all patients undergoing percutaneous ASD closure was conducted between March 2010 to November 2023. Patients who developed a pulmonary hypertensive crisis during the procedure were excluded. Procedural and echocardiographic parameter were measured and analyzed. Results: A total of 112 samples were included in this study, 74.1% were female and 55.36% were pediatric patients. The failure rate was 12.5% (n=14) with diameter index was higher in the failed group. Unpaired T-test revealed that ASD size was one of the predictor failure in pediatric patients (mean diameter: 24.7±6.46 mm vs. 16.36±5.94 mm, p=0.001). There were no statistically significant variations in rim diameters, while compared with all patients with appropriate rims (rim ≥7mm), the failure rate was higher in patients with two rims measuring between 5.9 and 6.9 mm and rims less than 5 mm. Two patients presented with device embolization and required surgical device removal. Conclusion: The failure rate of percutaneous ASD closure was 12.5%. A larger ASD increases the risk of failure of percutaneous closure in pediatric patients. Furthermore, patient with 5-6.9 mm on two or more rims as well as those with rim less than 5 mm, have a higher failure rate. Keywords: secundum atrial septal defect, percutaneous closure, failure rate
first_indexed 2024-04-24T19:50:07Z
format Article
id doaj.art-efe657e7a71143958fa2ee1a26d4338b
institution Directory Open Access Journal
issn 2527-4384
2527-3442
language English
last_indexed 2024-04-24T19:50:07Z
publishDate 2024-03-01
publisher Cell and BioPharmaceutical Institute
record_format Article
series MCBS (Molecular and Cellular Biomedical Sciences)
spelling doaj.art-efe657e7a71143958fa2ee1a26d4338b2024-03-25T00:56:10ZengCell and BioPharmaceutical InstituteMCBS (Molecular and Cellular Biomedical Sciences)2527-43842527-34422024-03-0181515710.21705/mcbs.v8i1.442132Percutaneous Secundum Atrial Septal Defect Closure: Failure Rate and Procedural PredictorsElien Yuwono0Eka Gunawijaya1Ni Putu Veny Kartika Yantie2Department of Child Health, Faculty of Medicine, Universitas Udayana/I G.N.G. Ngoerah Hospital, DenpasarDepartment of Child Health, Faculty of Medicine, Universitas Udayana/I G.N.G. Ngoerah Hospital, DenpasarDepartment of Child Health, Faculty of Medicine, Universitas Udayana/I G.N.G. Ngoerah Hospital, DenpasarBackground: Percutaneous atrial septal defect (ASD) closure is one of therapeutic options for patients with a suitable ASD anatomy, however in developing countries, the exact figure and procedural characteristics remain unknown. Therefore, this study was conducted to identify the failure rate and procedural predictors of the percutaneous ASD closure. Materials and methods: A retrospective study using a database of all patients undergoing percutaneous ASD closure was conducted between March 2010 to November 2023. Patients who developed a pulmonary hypertensive crisis during the procedure were excluded. Procedural and echocardiographic parameter were measured and analyzed. Results: A total of 112 samples were included in this study, 74.1% were female and 55.36% were pediatric patients. The failure rate was 12.5% (n=14) with diameter index was higher in the failed group. Unpaired T-test revealed that ASD size was one of the predictor failure in pediatric patients (mean diameter: 24.7±6.46 mm vs. 16.36±5.94 mm, p=0.001). There were no statistically significant variations in rim diameters, while compared with all patients with appropriate rims (rim ≥7mm), the failure rate was higher in patients with two rims measuring between 5.9 and 6.9 mm and rims less than 5 mm. Two patients presented with device embolization and required surgical device removal. Conclusion: The failure rate of percutaneous ASD closure was 12.5%. A larger ASD increases the risk of failure of percutaneous closure in pediatric patients. Furthermore, patient with 5-6.9 mm on two or more rims as well as those with rim less than 5 mm, have a higher failure rate. Keywords: secundum atrial septal defect, percutaneous closure, failure ratehttps://cellbiopharm.com/ojs/index.php/MCBS/article/view/442
spellingShingle Elien Yuwono
Eka Gunawijaya
Ni Putu Veny Kartika Yantie
Percutaneous Secundum Atrial Septal Defect Closure: Failure Rate and Procedural Predictors
MCBS (Molecular and Cellular Biomedical Sciences)
title Percutaneous Secundum Atrial Septal Defect Closure: Failure Rate and Procedural Predictors
title_full Percutaneous Secundum Atrial Septal Defect Closure: Failure Rate and Procedural Predictors
title_fullStr Percutaneous Secundum Atrial Septal Defect Closure: Failure Rate and Procedural Predictors
title_full_unstemmed Percutaneous Secundum Atrial Septal Defect Closure: Failure Rate and Procedural Predictors
title_short Percutaneous Secundum Atrial Septal Defect Closure: Failure Rate and Procedural Predictors
title_sort percutaneous secundum atrial septal defect closure failure rate and procedural predictors
url https://cellbiopharm.com/ojs/index.php/MCBS/article/view/442
work_keys_str_mv AT elienyuwono percutaneoussecundumatrialseptaldefectclosurefailurerateandproceduralpredictors
AT ekagunawijaya percutaneoussecundumatrialseptaldefectclosurefailurerateandproceduralpredictors
AT niputuvenykartikayantie percutaneoussecundumatrialseptaldefectclosurefailurerateandproceduralpredictors