Femtosecond laser FLEx surgery — first experience of application

ABSTRACT Purpose. A comparative estimation of the thickness of corneal flap formed with Moria microkeratome and VisuMax femtosecond laser as well as refraction, visual acuity, changes of contrast sensitivity and higher order aberrations after LASIK and FLEx for myopia and myopic astigmatism c...

Full description

Bibliographic Details
Main Authors: O.A. Kostin, S.V. Rebrikov, A.I. Ovchinnikov, A.A. Stepanov
Format: Article
Language:Russian
Published: Publishing house "Ophthalmology" 2013-01-01
Series:Офтальмохирургия
Subjects:
Online Access:http://www.eyepress.ru/article.aspx?11567
_version_ 1797946743894048768
author O.A. Kostin
S.V. Rebrikov
A.I. Ovchinnikov
A.A. Stepanov
author_facet O.A. Kostin
S.V. Rebrikov
A.I. Ovchinnikov
A.A. Stepanov
author_sort O.A. Kostin
collection DOAJ
description ABSTRACT Purpose. A comparative estimation of the thickness of corneal flap formed with Moria microkeratome and VisuMax femtosecond laser as well as refraction, visual acuity, changes of contrast sensitivity and higher order aberrations after LASIK and FLEx for myopia and myopic astigmatism correction. Material and methods. Two groups of patients, 70 eyes in each were investigated. In the group 1 the standard LASIK was performed. In the group 2 the FLEx was carried out. Besides standard investigations, in both groups wavefront aberrations were measured before operation and 1 month later in Malacara notation with WASCA aberrometer (Carl Zeiss Meditec, Germany) with a non-medicamentous pupil diameter of 6mm. Flap thickness measurement in the center of the cornea and 1, 2 and 3mm from the center was performed in both groups with the Visante OCT (Carl Zeiss Meditec) in High Resolution Corneal Quad and High Resolution Corneal Single modes. Contrast sensitivity was measured in both groups with CSV-1000 unit (VECTORVISION). Follow-up period was 1 month. Results. Uncorrected visual acuity before surgery in groups 1 and 2 was 0.05±0.07; 0.06±0.02 and made after the operation 0.99±0.05; 0.95±0.09 (p>0.05). Spheric equivalent before surgery in groups 1 and 2 was -4.13±2.08 D; -3.78±1.47 D and after surgery became 0.02±0.16 D; 0.03±0.14 D (p>0.05). Corrected visual acuity before surgery in groups 1 and 2 was 0.98±0.05; 0.99±0.02 and made 0.99±0.07; 0.98±0.04 after surgery (p>0.05). The RMS HO before surgery in groups 1 and 2 was 0.18±0.07 µm, 0.17±0.09 µm and increased after surgery up to 0.37±0.11 µm, 0.29±0.07 µm (p<0.05). Spheric aberration value in groups 1 and 2 before surgery was -0.12±0.19 µm; -0.11±0.15 µm, after surgery it increased negatively in both groups up to -0.53±0.30 µm; -0.24±0.28 µm (p<0.05). Conclusions. 1. Laser femtosecond microkeratome VisuMax allows FLEx without excimer laser. 2. Laser femtosecond microkeratome VisuMax allows a formation of corneal flaps with precisely preset thickness parameters unlike mechanical microkeratome. 3. FLEx provides an improvement of visual acuity up to preoperative best corrected level with restoration of preoperative contrast sensitivity parameters under mesopic conditions at 1 month after the operation.
first_indexed 2024-04-10T21:16:57Z
format Article
id doaj.art-f019af6c34124739b8010bf0f3c10870
institution Directory Open Access Journal
issn 0235-4160
0235-4160
language Russian
last_indexed 2024-04-10T21:16:57Z
publishDate 2013-01-01
publisher Publishing house "Ophthalmology"
record_format Article
series Офтальмохирургия
spelling doaj.art-f019af6c34124739b8010bf0f3c108702023-01-20T12:34:48ZrusPublishing house "Ophthalmology"Офтальмохирургия0235-41600235-41602013-01-0113639Femtosecond laser FLEx surgery — first experience of applicationO.A. Kostin0S.V. Rebrikov1A.I. Ovchinnikov2A.A. Stepanov3The S. Fyodorov Eye Microsurgery State Institution, the Ekaterinburg BranchThe S. Fyodorov Eye Microsurgery State Institution, the Ekaterinburg BranchThe S. Fyodorov Eye Microsurgery State Institution, the Ekaterinburg BranchThe S. Fyodorov Eye Microsurgery State Institution, the Ekaterinburg BranchABSTRACT Purpose. A comparative estimation of the thickness of corneal flap formed with Moria microkeratome and VisuMax femtosecond laser as well as refraction, visual acuity, changes of contrast sensitivity and higher order aberrations after LASIK and FLEx for myopia and myopic astigmatism correction. Material and methods. Two groups of patients, 70 eyes in each were investigated. In the group 1 the standard LASIK was performed. In the group 2 the FLEx was carried out. Besides standard investigations, in both groups wavefront aberrations were measured before operation and 1 month later in Malacara notation with WASCA aberrometer (Carl Zeiss Meditec, Germany) with a non-medicamentous pupil diameter of 6mm. Flap thickness measurement in the center of the cornea and 1, 2 and 3mm from the center was performed in both groups with the Visante OCT (Carl Zeiss Meditec) in High Resolution Corneal Quad and High Resolution Corneal Single modes. Contrast sensitivity was measured in both groups with CSV-1000 unit (VECTORVISION). Follow-up period was 1 month. Results. Uncorrected visual acuity before surgery in groups 1 and 2 was 0.05±0.07; 0.06±0.02 and made after the operation 0.99±0.05; 0.95±0.09 (p>0.05). Spheric equivalent before surgery in groups 1 and 2 was -4.13±2.08 D; -3.78±1.47 D and after surgery became 0.02±0.16 D; 0.03±0.14 D (p>0.05). Corrected visual acuity before surgery in groups 1 and 2 was 0.98±0.05; 0.99±0.02 and made 0.99±0.07; 0.98±0.04 after surgery (p>0.05). The RMS HO before surgery in groups 1 and 2 was 0.18±0.07 µm, 0.17±0.09 µm and increased after surgery up to 0.37±0.11 µm, 0.29±0.07 µm (p<0.05). Spheric aberration value in groups 1 and 2 before surgery was -0.12±0.19 µm; -0.11±0.15 µm, after surgery it increased negatively in both groups up to -0.53±0.30 µm; -0.24±0.28 µm (p<0.05). Conclusions. 1. Laser femtosecond microkeratome VisuMax allows FLEx without excimer laser. 2. Laser femtosecond microkeratome VisuMax allows a formation of corneal flaps with precisely preset thickness parameters unlike mechanical microkeratome. 3. FLEx provides an improvement of visual acuity up to preoperative best corrected level with restoration of preoperative contrast sensitivity parameters under mesopic conditions at 1 month after the operation.http://www.eyepress.ru/article.aspx?11567FLExLASIKfemtosecond laserspherical aberrationaberrometer
spellingShingle O.A. Kostin
S.V. Rebrikov
A.I. Ovchinnikov
A.A. Stepanov
Femtosecond laser FLEx surgery — first experience of application
Офтальмохирургия
FLEx
LASIK
femtosecond laser
spherical aberration
aberrometer
title Femtosecond laser FLEx surgery — first experience of application
title_full Femtosecond laser FLEx surgery — first experience of application
title_fullStr Femtosecond laser FLEx surgery — first experience of application
title_full_unstemmed Femtosecond laser FLEx surgery — first experience of application
title_short Femtosecond laser FLEx surgery — first experience of application
title_sort femtosecond laser flex surgery first experience of application
topic FLEx
LASIK
femtosecond laser
spherical aberration
aberrometer
url http://www.eyepress.ru/article.aspx?11567
work_keys_str_mv AT oakostin femtosecondlaserflexsurgeryfirstexperienceofapplication
AT svrebrikov femtosecondlaserflexsurgeryfirstexperienceofapplication
AT aiovchinnikov femtosecondlaserflexsurgeryfirstexperienceofapplication
AT aastepanov femtosecondlaserflexsurgeryfirstexperienceofapplication