Dynamic Performance Comparison of R134a and R1234yf Refrigerants for a Vapor Compression Refrigeration Cycle

M achines like air conditioners and refrigerators, which cause significant energy consumption in countries around the world, are widely used in industry and residences. Analyzing and studying the behavior of these machines with computer simulations can optimize performance of them. In this study, th...

Full description

Bibliographic Details
Main Authors: Mert Sinan Turgut, Mustafa Turhan Çoban
Format: Article
Language:English
Published: Hitit University 2018-09-01
Series:Hittite Journal of Science and Engineering
Subjects:
Online Access:https://dergipark.org.tr/tr/download/article-file/1506690
_version_ 1797662692471734272
author Mert Sinan Turgut
Mustafa Turhan Çoban
author_facet Mert Sinan Turgut
Mustafa Turhan Çoban
author_sort Mert Sinan Turgut
collection DOAJ
description M achines like air conditioners and refrigerators, which cause significant energy consumption in countries around the world, are widely used in industry and residences. Analyzing and studying the behavior of these machines with computer simulations can optimize performance of them. In this study, thermodynamic modelling and dynamic simulation of a vapor compression refrigeration cycle is handled. R134a and R1234yf are used as the primary fluid and water is used as the secondary fluid in the refrigeration cycle. R1234yf is a refrigerant, which has low Global Warming Potential GWP and Ozone Depletion Potential ODP and is recently has been begun to use as a substitute of R134a. In this study, dynamic behaviors of these two refrigerants are examined in a vapor compression refrigerant cycle with fixed operating conditions. Finite Difference Method is utilized for the modelling of the evaporator and condenser and Gungrr-Winterton and Travis et al. correlations are used for the modelling of the evaporation and condensation proccesses respectively. Orifice equation is utilized for the modelling of the expansion valve and modelling of the compressor is carried out by first dynamically simuating the heat transfer between the gas and surroundings until the gas reaches to compression chamber and after that the polytropic compression process in the chamber. For the realization of the dynamical simulation, refrigerant fluid mass flow rate is applied to the system as step input. Response of the system to the input is observed with transient p-h and coefficient of performance COP diagrams. The results showed that COP is started off with the values of 2.079 for R134a and 1.711 R1234yf, reached the maximum points of 2.577 for R134a and 2.02 for R1234yf, then slowly declined with fluctuations. In the p-h diagram, due to temperature rise of inner walls of the evaporator and condenser, condenser outlet and compressor inlet enthalpy values started off with 395,945 kJ/kg and 231,714 kJ/kg for R134a, 361,557 kJ/kg and 230,750 kJ/kg for R1234yf, then approached to the saturation curve with time and reached the values of 393,957 kJ/kg and 233,808 kJ/kg for R134a, 359,547 kJ/kg and 231,917 kJ/kg for R1234 yf
first_indexed 2024-03-11T19:03:54Z
format Article
id doaj.art-f022d2eb3cc446b9b86993dd92c12f0b
institution Directory Open Access Journal
issn 2148-4171
language English
last_indexed 2024-03-11T19:03:54Z
publishDate 2018-09-01
publisher Hitit University
record_format Article
series Hittite Journal of Science and Engineering
spelling doaj.art-f022d2eb3cc446b9b86993dd92c12f0b2023-10-10T11:17:27ZengHitit UniversityHittite Journal of Science and Engineering2148-41712018-09-015091410.17350/HJSE19030000114150Dynamic Performance Comparison of R134a and R1234yf Refrigerants for a Vapor Compression Refrigeration CycleMert Sinan Turgut0Mustafa Turhan Çoban1Ege University, Department of Mechanical Engineering, İzmir, TURKEYEge University, Department of Mechanical Engineering, İzmir, TURKEYM achines like air conditioners and refrigerators, which cause significant energy consumption in countries around the world, are widely used in industry and residences. Analyzing and studying the behavior of these machines with computer simulations can optimize performance of them. In this study, thermodynamic modelling and dynamic simulation of a vapor compression refrigeration cycle is handled. R134a and R1234yf are used as the primary fluid and water is used as the secondary fluid in the refrigeration cycle. R1234yf is a refrigerant, which has low Global Warming Potential GWP and Ozone Depletion Potential ODP and is recently has been begun to use as a substitute of R134a. In this study, dynamic behaviors of these two refrigerants are examined in a vapor compression refrigerant cycle with fixed operating conditions. Finite Difference Method is utilized for the modelling of the evaporator and condenser and Gungrr-Winterton and Travis et al. correlations are used for the modelling of the evaporation and condensation proccesses respectively. Orifice equation is utilized for the modelling of the expansion valve and modelling of the compressor is carried out by first dynamically simuating the heat transfer between the gas and surroundings until the gas reaches to compression chamber and after that the polytropic compression process in the chamber. For the realization of the dynamical simulation, refrigerant fluid mass flow rate is applied to the system as step input. Response of the system to the input is observed with transient p-h and coefficient of performance COP diagrams. The results showed that COP is started off with the values of 2.079 for R134a and 1.711 R1234yf, reached the maximum points of 2.577 for R134a and 2.02 for R1234yf, then slowly declined with fluctuations. In the p-h diagram, due to temperature rise of inner walls of the evaporator and condenser, condenser outlet and compressor inlet enthalpy values started off with 395,945 kJ/kg and 231,714 kJ/kg for R134a, 361,557 kJ/kg and 230,750 kJ/kg for R1234yf, then approached to the saturation curve with time and reached the values of 393,957 kJ/kg and 233,808 kJ/kg for R134a, 359,547 kJ/kg and 231,917 kJ/kg for R1234 yfhttps://dergipark.org.tr/tr/download/article-file/1506690refrigeration cyclesdynamic simulationsystem modellingthermodynamicsglobal warming potential
spellingShingle Mert Sinan Turgut
Mustafa Turhan Çoban
Dynamic Performance Comparison of R134a and R1234yf Refrigerants for a Vapor Compression Refrigeration Cycle
Hittite Journal of Science and Engineering
refrigeration cycles
dynamic simulation
system modelling
thermodynamics
global warming potential
title Dynamic Performance Comparison of R134a and R1234yf Refrigerants for a Vapor Compression Refrigeration Cycle
title_full Dynamic Performance Comparison of R134a and R1234yf Refrigerants for a Vapor Compression Refrigeration Cycle
title_fullStr Dynamic Performance Comparison of R134a and R1234yf Refrigerants for a Vapor Compression Refrigeration Cycle
title_full_unstemmed Dynamic Performance Comparison of R134a and R1234yf Refrigerants for a Vapor Compression Refrigeration Cycle
title_short Dynamic Performance Comparison of R134a and R1234yf Refrigerants for a Vapor Compression Refrigeration Cycle
title_sort dynamic performance comparison of r134a and r1234yf refrigerants for a vapor compression refrigeration cycle
topic refrigeration cycles
dynamic simulation
system modelling
thermodynamics
global warming potential
url https://dergipark.org.tr/tr/download/article-file/1506690
work_keys_str_mv AT mertsinanturgut dynamicperformancecomparisonofr134aandr1234yfrefrigerantsforavaporcompressionrefrigerationcycle
AT mustafaturhancoban dynamicperformancecomparisonofr134aandr1234yfrefrigerantsforavaporcompressionrefrigerationcycle