A novel slit-integration method of graft urethroplasty in the prevention of ring recurrence: Short-term results of a pilot study

Purpose: To describe and evaluate the efficacy of the slit-integration method in the prevention of ring recurrence after graft substitution urethroplasty. Materials and Methods: This was a pilot study of selected patients with urethral stricture disease who required urethroplasty from January 2016 t...

Full description

Bibliographic Details
Main Authors: Abdulwahab Akanbi Ajape, Sulyman Alege Kuranga, Hamid Babajide Olanipekun, Taofiq Olayinka Mohammed
Format: Article
Language:English
Published: Korean Urological Association 2019-07-01
Series:Investigative and Clinical Urology
Subjects:
Online Access:https://www.icurology.org/Synapse/Data/PDFData/2020ICU/icu-60-319.pdf
_version_ 1817970188780306432
author Abdulwahab Akanbi Ajape
Sulyman Alege Kuranga
Hamid Babajide Olanipekun
Taofiq Olayinka Mohammed
author_facet Abdulwahab Akanbi Ajape
Sulyman Alege Kuranga
Hamid Babajide Olanipekun
Taofiq Olayinka Mohammed
author_sort Abdulwahab Akanbi Ajape
collection DOAJ
description Purpose: To describe and evaluate the efficacy of the slit-integration method in the prevention of ring recurrence after graft substitution urethroplasty. Materials and Methods: This was a pilot study of selected patients with urethral stricture disease who required urethroplasty from January 2016 to December 2018. Patients were recruited into the study after they granted informed consent about the procedure. Results: A total of eight patients were involved in this pilot study. The mean age (±standard deviation, SD) of the patients and the mean stricture length (±SD) were 44.25 (±11.07) years and 3.88 (±1.25) cm, respectively. The peno-bulbar region was the most frequently involved. The majority of the patients, 7 of 8 patients, underwent buccal mucosal graft repair with a mean graft length of 5.88 cm (range, 4–8 cm). There was leak during pericatheter urethrography in one patient. The mean (±SD) urethral calibers of the distal and proximal urethral anastomotic sites following urethroplasty were 26.00 (±1.85) and 25.25 (±1.83) at 1 week after removal of the urethral catheter stent and 27.75 (±0.71) and 27.75 (±0.71) at 12 months postoperatively, respectively. The mean maximum flow rate (±SD) at the 6- and 12-month follow-up was 20.25 (±1.83) and 21.88 (±1.73) mL/s, respectively. Conclusions: A slit-graft appropriately quilted into the corresponding urethrotomy incisions at the proximal and distal summit of the urethral stricture segments appears to mitigate the occurrence of ring contracture after urethroplasty. A randomized controlled trial of this technique with additional outcome assessment will be required to validate this observation.
first_indexed 2024-04-13T20:30:56Z
format Article
id doaj.art-f088070ef3574d7bb687970eb4143a21
institution Directory Open Access Journal
issn 2466-0493
2466-054X
language English
last_indexed 2024-04-13T20:30:56Z
publishDate 2019-07-01
publisher Korean Urological Association
record_format Article
series Investigative and Clinical Urology
spelling doaj.art-f088070ef3574d7bb687970eb4143a212022-12-22T02:31:11ZengKorean Urological AssociationInvestigative and Clinical Urology2466-04932466-054X2019-07-0160431932510.4111/icu.2019.60.4.319A novel slit-integration method of graft urethroplasty in the prevention of ring recurrence: Short-term results of a pilot studyAbdulwahab Akanbi Ajape0Sulyman Alege Kuranga1Hamid Babajide Olanipekun2Taofiq Olayinka Mohammed 3Division of Urology, Department of Surgery, University of Ilorin and University of Ilorin Teaching Hospital, Ilorin, Nigeria.Division of Urology, Department of Surgery, University of Ilorin and University of Ilorin Teaching Hospital, Ilorin, Nigeria.Division of Urology, Department of Surgery, University of Ilorin and University of Ilorin Teaching Hospital, Ilorin, Nigeria.Division of Urology, Department of Surgery, University of Ilorin and University of Ilorin Teaching Hospital, Ilorin, Nigeria.Purpose: To describe and evaluate the efficacy of the slit-integration method in the prevention of ring recurrence after graft substitution urethroplasty. Materials and Methods: This was a pilot study of selected patients with urethral stricture disease who required urethroplasty from January 2016 to December 2018. Patients were recruited into the study after they granted informed consent about the procedure. Results: A total of eight patients were involved in this pilot study. The mean age (±standard deviation, SD) of the patients and the mean stricture length (±SD) were 44.25 (±11.07) years and 3.88 (±1.25) cm, respectively. The peno-bulbar region was the most frequently involved. The majority of the patients, 7 of 8 patients, underwent buccal mucosal graft repair with a mean graft length of 5.88 cm (range, 4–8 cm). There was leak during pericatheter urethrography in one patient. The mean (±SD) urethral calibers of the distal and proximal urethral anastomotic sites following urethroplasty were 26.00 (±1.85) and 25.25 (±1.83) at 1 week after removal of the urethral catheter stent and 27.75 (±0.71) and 27.75 (±0.71) at 12 months postoperatively, respectively. The mean maximum flow rate (±SD) at the 6- and 12-month follow-up was 20.25 (±1.83) and 21.88 (±1.73) mL/s, respectively. Conclusions: A slit-graft appropriately quilted into the corresponding urethrotomy incisions at the proximal and distal summit of the urethral stricture segments appears to mitigate the occurrence of ring contracture after urethroplasty. A randomized controlled trial of this technique with additional outcome assessment will be required to validate this observation.https://www.icurology.org/Synapse/Data/PDFData/2020ICU/icu-60-319.pdfPericatheter urethrogramRing recurrenceSlit-graft urethroplastyUrethral calibrationUrethral stricture
spellingShingle Abdulwahab Akanbi Ajape
Sulyman Alege Kuranga
Hamid Babajide Olanipekun
Taofiq Olayinka Mohammed
A novel slit-integration method of graft urethroplasty in the prevention of ring recurrence: Short-term results of a pilot study
Investigative and Clinical Urology
Pericatheter urethrogram
Ring recurrence
Slit-graft urethroplasty
Urethral calibration
Urethral stricture
title A novel slit-integration method of graft urethroplasty in the prevention of ring recurrence: Short-term results of a pilot study
title_full A novel slit-integration method of graft urethroplasty in the prevention of ring recurrence: Short-term results of a pilot study
title_fullStr A novel slit-integration method of graft urethroplasty in the prevention of ring recurrence: Short-term results of a pilot study
title_full_unstemmed A novel slit-integration method of graft urethroplasty in the prevention of ring recurrence: Short-term results of a pilot study
title_short A novel slit-integration method of graft urethroplasty in the prevention of ring recurrence: Short-term results of a pilot study
title_sort novel slit integration method of graft urethroplasty in the prevention of ring recurrence short term results of a pilot study
topic Pericatheter urethrogram
Ring recurrence
Slit-graft urethroplasty
Urethral calibration
Urethral stricture
url https://www.icurology.org/Synapse/Data/PDFData/2020ICU/icu-60-319.pdf
work_keys_str_mv AT abdulwahabakanbiajape anovelslitintegrationmethodofgrafturethroplastyinthepreventionofringrecurrenceshorttermresultsofapilotstudy
AT sulymanalegekuranga anovelslitintegrationmethodofgrafturethroplastyinthepreventionofringrecurrenceshorttermresultsofapilotstudy
AT hamidbabajideolanipekun anovelslitintegrationmethodofgrafturethroplastyinthepreventionofringrecurrenceshorttermresultsofapilotstudy
AT taofiqolayinkamohammed anovelslitintegrationmethodofgrafturethroplastyinthepreventionofringrecurrenceshorttermresultsofapilotstudy
AT abdulwahabakanbiajape novelslitintegrationmethodofgrafturethroplastyinthepreventionofringrecurrenceshorttermresultsofapilotstudy
AT sulymanalegekuranga novelslitintegrationmethodofgrafturethroplastyinthepreventionofringrecurrenceshorttermresultsofapilotstudy
AT hamidbabajideolanipekun novelslitintegrationmethodofgrafturethroplastyinthepreventionofringrecurrenceshorttermresultsofapilotstudy
AT taofiqolayinkamohammed novelslitintegrationmethodofgrafturethroplastyinthepreventionofringrecurrenceshorttermresultsofapilotstudy