Close accord on partial discharge diagnosis during voltage harmonics in electric motors fed by variable frequency drives

Abstract Partial discharge (PD) diagnostics test is a reliable solution for estimating insulation health conditions in power system components. During laboratory PD diagnostics, the effect of harmonic components in the voltage waveform generated by variable frequency drives (VFD) fed electric motors...

Full description

Bibliographic Details
Main Authors: Waqar Hassan, Muhammad Akmal, Ghulam Amjad Hussain, Ali Raza, Muhammad Shafiq
Format: Article
Language:English
Published: Wiley 2024-02-01
Series:IET Generation, Transmission & Distribution
Subjects:
Online Access:https://doi.org/10.1049/gtd2.13089
_version_ 1797333715236421632
author Waqar Hassan
Muhammad Akmal
Ghulam Amjad Hussain
Ali Raza
Muhammad Shafiq
author_facet Waqar Hassan
Muhammad Akmal
Ghulam Amjad Hussain
Ali Raza
Muhammad Shafiq
author_sort Waqar Hassan
collection DOAJ
description Abstract Partial discharge (PD) diagnostics test is a reliable solution for estimating insulation health conditions in power system components. During laboratory PD diagnostics, the effect of harmonic components in the voltage waveform generated by variable frequency drives (VFD) fed electric motors (EMs) is often overlooked. As VFD‐fed EMs operate at low speeds, the harmonic concentration in the voltage increases. It has been found that PD activity in VFD‐fed EM is significantly affected by the addition of harmonic components in the voltage, thus making it necessary to consider their impact when performing true PD diagnostics. This paper investigates the influence of voltage harmonic distortion produced in VFD‐fed EM on PD severity and the subsequent insulation degradation. Eight VFD‐fed EM are used to study the PD behaviour under different levels of harmonic pollution. The PD characteristics, such as inception voltage, pulse repetition rate, accumulated apparent charge, average discharge current, discharge power, and quadratic rate, are determined. Using probability distribution functions, PD activity and severity at various voltage harmonic levels are estimated. The proposed technique can be used to plan the maintenance activities that ensure the reliability for industrial applications dealing with the voltage harmonic distortion.
first_indexed 2024-03-08T08:08:59Z
format Article
id doaj.art-f0b8f8e3920a4ea3b38a1cfef512caac
institution Directory Open Access Journal
issn 1751-8687
1751-8695
language English
last_indexed 2024-03-08T08:08:59Z
publishDate 2024-02-01
publisher Wiley
record_format Article
series IET Generation, Transmission & Distribution
spelling doaj.art-f0b8f8e3920a4ea3b38a1cfef512caac2024-02-02T10:00:26ZengWileyIET Generation, Transmission & Distribution1751-86871751-86952024-02-0118350651610.1049/gtd2.13089Close accord on partial discharge diagnosis during voltage harmonics in electric motors fed by variable frequency drivesWaqar Hassan0Muhammad Akmal1Ghulam Amjad Hussain2Ali Raza3Muhammad Shafiq4Institute of Power Engineering (IPE) Universiti Tenaga Nasional (UNITEN) Kajang MalaysiaDepartment of Engineering and Mathematics Sheffield Hallam University Sheffield UKCollege of Engineering and Applied Sciences American University of Kuwait Salmiya KuwaitDepartment of Electrical Engineering University of Engineering and Technology Lahore PakistanCenter for Advanced Power Systems Florida State University Tallahassee Florida USAAbstract Partial discharge (PD) diagnostics test is a reliable solution for estimating insulation health conditions in power system components. During laboratory PD diagnostics, the effect of harmonic components in the voltage waveform generated by variable frequency drives (VFD) fed electric motors (EMs) is often overlooked. As VFD‐fed EMs operate at low speeds, the harmonic concentration in the voltage increases. It has been found that PD activity in VFD‐fed EM is significantly affected by the addition of harmonic components in the voltage, thus making it necessary to consider their impact when performing true PD diagnostics. This paper investigates the influence of voltage harmonic distortion produced in VFD‐fed EM on PD severity and the subsequent insulation degradation. Eight VFD‐fed EM are used to study the PD behaviour under different levels of harmonic pollution. The PD characteristics, such as inception voltage, pulse repetition rate, accumulated apparent charge, average discharge current, discharge power, and quadratic rate, are determined. Using probability distribution functions, PD activity and severity at various voltage harmonic levels are estimated. The proposed technique can be used to plan the maintenance activities that ensure the reliability for industrial applications dealing with the voltage harmonic distortion.https://doi.org/10.1049/gtd2.13089AC motorsharmonic distortionpartial discharge measurementvariable speed drives
spellingShingle Waqar Hassan
Muhammad Akmal
Ghulam Amjad Hussain
Ali Raza
Muhammad Shafiq
Close accord on partial discharge diagnosis during voltage harmonics in electric motors fed by variable frequency drives
IET Generation, Transmission & Distribution
AC motors
harmonic distortion
partial discharge measurement
variable speed drives
title Close accord on partial discharge diagnosis during voltage harmonics in electric motors fed by variable frequency drives
title_full Close accord on partial discharge diagnosis during voltage harmonics in electric motors fed by variable frequency drives
title_fullStr Close accord on partial discharge diagnosis during voltage harmonics in electric motors fed by variable frequency drives
title_full_unstemmed Close accord on partial discharge diagnosis during voltage harmonics in electric motors fed by variable frequency drives
title_short Close accord on partial discharge diagnosis during voltage harmonics in electric motors fed by variable frequency drives
title_sort close accord on partial discharge diagnosis during voltage harmonics in electric motors fed by variable frequency drives
topic AC motors
harmonic distortion
partial discharge measurement
variable speed drives
url https://doi.org/10.1049/gtd2.13089
work_keys_str_mv AT waqarhassan closeaccordonpartialdischargediagnosisduringvoltageharmonicsinelectricmotorsfedbyvariablefrequencydrives
AT muhammadakmal closeaccordonpartialdischargediagnosisduringvoltageharmonicsinelectricmotorsfedbyvariablefrequencydrives
AT ghulamamjadhussain closeaccordonpartialdischargediagnosisduringvoltageharmonicsinelectricmotorsfedbyvariablefrequencydrives
AT aliraza closeaccordonpartialdischargediagnosisduringvoltageharmonicsinelectricmotorsfedbyvariablefrequencydrives
AT muhammadshafiq closeaccordonpartialdischargediagnosisduringvoltageharmonicsinelectricmotorsfedbyvariablefrequencydrives