Novel Microfluidic Septum to Optimize Energy Recovery in Single-Chamber Microbial Fuel Cells

This study proposes a redesign of asymmetric single-chamber microbial fuel cells (a-SCMFCs) with the goal of optimizing energy production. In the present work, the new approach is based on the introduction of a novel intermediate microfluidic septum (IMS) inside the electrolyte chamber. This IMS was...

Full description

Bibliographic Details
Main Authors: Giacomo Spisni, Giulia Massaglia, Valentina Bertana, Nicolò Vasile, Fabrizio C. Pirri, Stefano Bianco, Marzia Quaglio
Format: Article
Language:English
Published: MDPI AG 2023-10-01
Series:Applied Sciences
Subjects:
Online Access:https://www.mdpi.com/2076-3417/13/20/11423
Description
Summary:This study proposes a redesign of asymmetric single-chamber microbial fuel cells (a-SCMFCs) with the goal of optimizing energy production. In the present work, the new approach is based on the introduction of a novel intermediate microfluidic septum (IMS) inside the electrolyte chamber. This IMS was designed as a relatively simple and inexpensive method to optimize both electrolyte flow and species transfer inside the devices. a-SCMFCs, featuring the IMS, are compared to control cells (IMS-less), when operated with sodium acetate as the carbon energy source. Performances of cells are evaluated in terms both of maximum output potential achieved, and energy recovery (<i>E<sub>rec</sub></i>) as the ratio between the energy yield and the inner electrolyte volume. The a-SCMFCs with the novel IMS are demonstrated to enhance the energy recovery compared to control cells exhibiting <i>E<sub>rec</sub></i> values of (37 ± 1) J/m<sup>3</sup>, which is one order of magnitude higher than that achieved by control cells (3.0 ± 0.3) J/m<sup>3</sup>. Concerning the maximum output potential, IMS cells achieve (2.8 ± 0.2) mV, compared to control cells at (0.68 ± 0.07) mV. Furthermore, by varying the sodium acetate concentration, the <i>E<sub>rec</sub></i> and maximum potential output values change accordingly. By monitoring the activity of a-SCMFCs for over one year, the beneficial impact of the IMS on both the initial inoculation phase and the long-term stability of electrical performance are observed. These improvements support the effectiveness of IMS to allow the development of efficient biofilms, likely due to the reduction in oxygen cross-over towards the anode. Electrochemical characterizations confirm that the presence of the IMS impacts the diffusion processes inside the electrolytic chamber, supporting the hypothesis of a beneficial effect on oxygen cross-over.
ISSN:2076-3417