ANÁLISE DE CONTROLE DE DOPING POR ACETAZOLAMIDA UTILIZANDO O SENSOR ELETROQUÍMICO BASEADO NO EPCM-[MnIII/IV(µ-O)(phen)2]2(ClO4)3

The preparation and electrochemical characterization of an electrochemical sensor based on carbon paste electrode modified with [MnIII/IV(µ-O)(phen)2]2(ClO4)3, as well as its application in detection of acetazolamide with interest in doping control analysis are related. The electrochemical behav...

Full description

Bibliographic Details
Main Authors: Wesley Bruno da Silva Machini, Marcos Fernando de Souza Teixeira
Format: Article
Language:Portuguese
Published: Universidade do Oeste Paulista 2014-09-01
Series:Colloquium Exactarum
Subjects:
Online Access:http://revistas.unoeste.br/revistas/ojs/index.php/ce/article/view/1129/1190
_version_ 1811281566423318528
author Wesley Bruno da Silva Machini
Marcos Fernando de Souza Teixeira
author_facet Wesley Bruno da Silva Machini
Marcos Fernando de Souza Teixeira
author_sort Wesley Bruno da Silva Machini
collection DOAJ
description The preparation and electrochemical characterization of an electrochemical sensor based on carbon paste electrode modified with [MnIII/IV(µ-O)(phen)2]2(ClO4)3, as well as its application in detection of acetazolamide with interest in doping control analysis are related. The electrochemical behavior of the sensor and the electrooxidation of ACTZ were investigated using the technique of cyclic and linear sweep voltammetry, respectively. The cyclic voltammogram for the electrochemical sensor showed one redox process assigned to MnIII/IV/MnIV/IV couple and electrocatalytic properties in oxidation of ACTZ. The voltammetric response was obtained in a concentration range from 5.00 × 10-7 mol L-1 to 5.00 × 10-6 mol L-1 , being the linear response from 5.00 × 10-7 mol L-1 to 3.50 × 10-6 mol L-1 with limit of quantification 9.90 × 10-5 mol L-1 , limit of detection 2.97 × 10-6 mol L-1 e sensitivity of 39.29 μA L mol-1 .
first_indexed 2024-04-13T01:35:55Z
format Article
id doaj.art-f1656763346f4eb19756c6560e747043
institution Directory Open Access Journal
issn 2178-8332
language Portuguese
last_indexed 2024-04-13T01:35:55Z
publishDate 2014-09-01
publisher Universidade do Oeste Paulista
record_format Article
series Colloquium Exactarum
spelling doaj.art-f1656763346f4eb19756c6560e7470432022-12-22T03:08:22ZporUniversidade do Oeste PaulistaColloquium Exactarum2178-83322014-09-010603455310.5747/ce.2014.v06.n3.e087ANÁLISE DE CONTROLE DE DOPING POR ACETAZOLAMIDA UTILIZANDO O SENSOR ELETROQUÍMICO BASEADO NO EPCM-[MnIII/IV(µ-O)(phen)2]2(ClO4)3Wesley Bruno da Silva Machini0Marcos Fernando de Souza Teixeira1Universidade Estadual PaulistaUniversidade Estadual PaulistaThe preparation and electrochemical characterization of an electrochemical sensor based on carbon paste electrode modified with [MnIII/IV(µ-O)(phen)2]2(ClO4)3, as well as its application in detection of acetazolamide with interest in doping control analysis are related. The electrochemical behavior of the sensor and the electrooxidation of ACTZ were investigated using the technique of cyclic and linear sweep voltammetry, respectively. The cyclic voltammogram for the electrochemical sensor showed one redox process assigned to MnIII/IV/MnIV/IV couple and electrocatalytic properties in oxidation of ACTZ. The voltammetric response was obtained in a concentration range from 5.00 × 10-7 mol L-1 to 5.00 × 10-6 mol L-1 , being the linear response from 5.00 × 10-7 mol L-1 to 3.50 × 10-6 mol L-1 with limit of quantification 9.90 × 10-5 mol L-1 , limit of detection 2.97 × 10-6 mol L-1 e sensitivity of 39.29 μA L mol-1 .http://revistas.unoeste.br/revistas/ojs/index.php/ce/article/view/1129/1190acetazolamidedopingelectrochemical sensor
spellingShingle Wesley Bruno da Silva Machini
Marcos Fernando de Souza Teixeira
ANÁLISE DE CONTROLE DE DOPING POR ACETAZOLAMIDA UTILIZANDO O SENSOR ELETROQUÍMICO BASEADO NO EPCM-[MnIII/IV(µ-O)(phen)2]2(ClO4)3
Colloquium Exactarum
acetazolamide
doping
electrochemical sensor
title ANÁLISE DE CONTROLE DE DOPING POR ACETAZOLAMIDA UTILIZANDO O SENSOR ELETROQUÍMICO BASEADO NO EPCM-[MnIII/IV(µ-O)(phen)2]2(ClO4)3
title_full ANÁLISE DE CONTROLE DE DOPING POR ACETAZOLAMIDA UTILIZANDO O SENSOR ELETROQUÍMICO BASEADO NO EPCM-[MnIII/IV(µ-O)(phen)2]2(ClO4)3
title_fullStr ANÁLISE DE CONTROLE DE DOPING POR ACETAZOLAMIDA UTILIZANDO O SENSOR ELETROQUÍMICO BASEADO NO EPCM-[MnIII/IV(µ-O)(phen)2]2(ClO4)3
title_full_unstemmed ANÁLISE DE CONTROLE DE DOPING POR ACETAZOLAMIDA UTILIZANDO O SENSOR ELETROQUÍMICO BASEADO NO EPCM-[MnIII/IV(µ-O)(phen)2]2(ClO4)3
title_short ANÁLISE DE CONTROLE DE DOPING POR ACETAZOLAMIDA UTILIZANDO O SENSOR ELETROQUÍMICO BASEADO NO EPCM-[MnIII/IV(µ-O)(phen)2]2(ClO4)3
title_sort analise de controle de doping por acetazolamida utilizando o sensor eletroquimico baseado no epcm mniii iv µ o phen 2 2 clo4 3
topic acetazolamide
doping
electrochemical sensor
url http://revistas.unoeste.br/revistas/ojs/index.php/ce/article/view/1129/1190
work_keys_str_mv AT wesleybrunodasilvamachini analisedecontrolededopingporacetazolamidautilizandoosensoreletroquimicobaseadonoepcmmniiiivμophen22clo43
AT marcosfernandodesouzateixeira analisedecontrolededopingporacetazolamidautilizandoosensoreletroquimicobaseadonoepcmmniiiivμophen22clo43