Usefulness of non-contact mapping for catheter ablation of ventricular tachycardias originating at the right ventricular outflow tract

Background: Different QRS morphologies are often observed in idiopathic ventricular tachycardias or premature ventricular contractions originating from the right ventricular outflow tract (RVOT). However, the precise mechanism underlying multiple QRS morphologies has not been clarified adequately. T...

Full description

Bibliographic Details
Main Authors: Tadashi Hoshiyama, MD, Hiroshige Yamabe, MD, PhD, FJCC, Junjiroh Koyama, MD, PhD, Hisanori Kanazawa, MD, Miwa Ito, MD, Hisao Ogawa, MD, PhD, FJCC
Format: Article
Language:English
Published: Wiley 2014-08-01
Series:Journal of Arrhythmia
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1880427614000696
_version_ 1818541269731770368
author Tadashi Hoshiyama, MD
Hiroshige Yamabe, MD, PhD, FJCC
Junjiroh Koyama, MD, PhD
Hisanori Kanazawa, MD
Miwa Ito, MD
Hisao Ogawa, MD, PhD, FJCC
author_facet Tadashi Hoshiyama, MD
Hiroshige Yamabe, MD, PhD, FJCC
Junjiroh Koyama, MD, PhD
Hisanori Kanazawa, MD
Miwa Ito, MD
Hisao Ogawa, MD, PhD, FJCC
author_sort Tadashi Hoshiyama, MD
collection DOAJ
description Background: Different QRS morphologies are often observed in idiopathic ventricular tachycardias or premature ventricular contractions originating from the right ventricular outflow tract (RVOT). However, the precise mechanism underlying multiple QRS morphologies has not been clarified adequately. The purpose of this study was to examine the mechanism underlying different QRS morphologies in RVOT arrhythmia. We also investigated the usefulness of non-contact mapping guided radiofrequency catheter ablation for RVOT arrhythmia. Methods: Endocardial mapping of RVOT was performed using a non-contact mapping system in 20 patients with RVOT arrhythmia. We analyzed the underlying mechanism that produces different QRS morphologies during catheter ablation of RVOT arrhythmia. Results: Forty-six QRS morphologies of RVOT arrhythmia were observed in 20 patients. Five patients showed monofocal QRS morphology, whereas the remaining 15 patients showed multiple QRS morphologies (from 2 to 4 morphologies each). Among these, all patients presented a shift in the origin of tachycardia. Additionally, different QRS morphologies were observed in 5 of these patients that were caused by a change in the local activation after radiofrequency energy delivery. Radiofrequency energy application to the site of origin of the RVOT arrhythmia using non-contact mapping navigation eliminated the RVOT arrhythmias in all patients. However, 1 patient presented a recurrence of RVOT arrhythmia (success rate, 95.0%). Conclusions: The multiple QRS morphologies of RVOT arrhythmia were caused by a shift in the origin of tachycardia or by a change in the local activation following the radiofrequency energy application. Non-contact mapping was useful to identify the appropriate target site of RVOT arrhythmia irrespective of the changes in QRS morphologies.
first_indexed 2024-12-11T22:06:26Z
format Article
id doaj.art-f17f77ef22df424f95cd9b547ada4db5
institution Directory Open Access Journal
issn 1880-4276
language English
last_indexed 2024-12-11T22:06:26Z
publishDate 2014-08-01
publisher Wiley
record_format Article
series Journal of Arrhythmia
spelling doaj.art-f17f77ef22df424f95cd9b547ada4db52022-12-22T00:48:57ZengWileyJournal of Arrhythmia1880-42762014-08-0130430531110.1016/j.joa.2014.03.010Usefulness of non-contact mapping for catheter ablation of ventricular tachycardias originating at the right ventricular outflow tractTadashi Hoshiyama, MDHiroshige Yamabe, MD, PhD, FJCCJunjiroh Koyama, MD, PhDHisanori Kanazawa, MDMiwa Ito, MDHisao Ogawa, MD, PhD, FJCCBackground: Different QRS morphologies are often observed in idiopathic ventricular tachycardias or premature ventricular contractions originating from the right ventricular outflow tract (RVOT). However, the precise mechanism underlying multiple QRS morphologies has not been clarified adequately. The purpose of this study was to examine the mechanism underlying different QRS morphologies in RVOT arrhythmia. We also investigated the usefulness of non-contact mapping guided radiofrequency catheter ablation for RVOT arrhythmia. Methods: Endocardial mapping of RVOT was performed using a non-contact mapping system in 20 patients with RVOT arrhythmia. We analyzed the underlying mechanism that produces different QRS morphologies during catheter ablation of RVOT arrhythmia. Results: Forty-six QRS morphologies of RVOT arrhythmia were observed in 20 patients. Five patients showed monofocal QRS morphology, whereas the remaining 15 patients showed multiple QRS morphologies (from 2 to 4 morphologies each). Among these, all patients presented a shift in the origin of tachycardia. Additionally, different QRS morphologies were observed in 5 of these patients that were caused by a change in the local activation after radiofrequency energy delivery. Radiofrequency energy application to the site of origin of the RVOT arrhythmia using non-contact mapping navigation eliminated the RVOT arrhythmias in all patients. However, 1 patient presented a recurrence of RVOT arrhythmia (success rate, 95.0%). Conclusions: The multiple QRS morphologies of RVOT arrhythmia were caused by a shift in the origin of tachycardia or by a change in the local activation following the radiofrequency energy application. Non-contact mapping was useful to identify the appropriate target site of RVOT arrhythmia irrespective of the changes in QRS morphologies.http://www.sciencedirect.com/science/article/pii/S1880427614000696Ventricular arrhythmiaRight ventricular outflow tractNon-contact mappingCatheter ablation
spellingShingle Tadashi Hoshiyama, MD
Hiroshige Yamabe, MD, PhD, FJCC
Junjiroh Koyama, MD, PhD
Hisanori Kanazawa, MD
Miwa Ito, MD
Hisao Ogawa, MD, PhD, FJCC
Usefulness of non-contact mapping for catheter ablation of ventricular tachycardias originating at the right ventricular outflow tract
Journal of Arrhythmia
Ventricular arrhythmia
Right ventricular outflow tract
Non-contact mapping
Catheter ablation
title Usefulness of non-contact mapping for catheter ablation of ventricular tachycardias originating at the right ventricular outflow tract
title_full Usefulness of non-contact mapping for catheter ablation of ventricular tachycardias originating at the right ventricular outflow tract
title_fullStr Usefulness of non-contact mapping for catheter ablation of ventricular tachycardias originating at the right ventricular outflow tract
title_full_unstemmed Usefulness of non-contact mapping for catheter ablation of ventricular tachycardias originating at the right ventricular outflow tract
title_short Usefulness of non-contact mapping for catheter ablation of ventricular tachycardias originating at the right ventricular outflow tract
title_sort usefulness of non contact mapping for catheter ablation of ventricular tachycardias originating at the right ventricular outflow tract
topic Ventricular arrhythmia
Right ventricular outflow tract
Non-contact mapping
Catheter ablation
url http://www.sciencedirect.com/science/article/pii/S1880427614000696
work_keys_str_mv AT tadashihoshiyamamd usefulnessofnoncontactmappingforcatheterablationofventriculartachycardiasoriginatingattherightventricularoutflowtract
AT hiroshigeyamabemdphdfjcc usefulnessofnoncontactmappingforcatheterablationofventriculartachycardiasoriginatingattherightventricularoutflowtract
AT junjirohkoyamamdphd usefulnessofnoncontactmappingforcatheterablationofventriculartachycardiasoriginatingattherightventricularoutflowtract
AT hisanorikanazawamd usefulnessofnoncontactmappingforcatheterablationofventriculartachycardiasoriginatingattherightventricularoutflowtract
AT miwaitomd usefulnessofnoncontactmappingforcatheterablationofventriculartachycardiasoriginatingattherightventricularoutflowtract
AT hisaoogawamdphdfjcc usefulnessofnoncontactmappingforcatheterablationofventriculartachycardiasoriginatingattherightventricularoutflowtract