Adapting the benefits and applications of traditional atriums and circular ceilings, with emphasis on optimizing energy consumption in commercial centers of Tehran

This research deals with an efficient approach to achieve energy efficiency optimization solutions with emphasis on the thermal role of atrium in commercial centers in the central part of Tehran and based on simulation. These studies, which are performed with high computational accuracy and dynamic...

Full description

Bibliographic Details
Main Authors: Amir Shayanian, Fatemeh Mozaffari Qhadikolaei
Format: Article
Language:fas
Published: The Institute of Islamic Art Studies 2022-05-01
Series:هنر اسلامی
Subjects:
Online Access:http://www.sysislamicartjournal.ir/article_127411_8d1dd34274e57395e0a89b9a255fa679.pdf
_version_ 1797858918844596224
author Amir Shayanian
Fatemeh Mozaffari Qhadikolaei
author_facet Amir Shayanian
Fatemeh Mozaffari Qhadikolaei
author_sort Amir Shayanian
collection DOAJ
description This research deals with an efficient approach to achieve energy efficiency optimization solutions with emphasis on the thermal role of atrium in commercial centers in the central part of Tehran and based on simulation. These studies, which are performed with high computational accuracy and dynamic modeling with design builder software, show that the potential for increasing productivity and energy savings in these buildings is very high. One of the main features of this doctoral dissertation is the use of 9 simultaneous variables and the application of a combination of architectural techniques and intelligent technologies in the building based on computer simulation. The research method in this research, according to its nature, is simulation with a case study and analytical approach and in terms of application type. In this research, first, the basic model is validated according to the consumption bills of the desired business center. It is then analyzed by comparing 11 different phases in the software. After applying energy efficiency and building intelligence solutions, it is found that the central atrium in short-level (3 floors), medium-level (5 floors) and then high-rise (13 floors) commercial centers, respectively, better efficiency than the base model without Apply solutions and remove the side walls in these atria, improve natural ventilation in the building
first_indexed 2024-04-09T21:22:13Z
format Article
id doaj.art-f1c0087e96134dcdb08dc5152c04c7b4
institution Directory Open Access Journal
issn 1735-708X
2676-7759
language fas
last_indexed 2024-04-09T21:22:13Z
publishDate 2022-05-01
publisher The Institute of Islamic Art Studies
record_format Article
series هنر اسلامی
spelling doaj.art-f1c0087e96134dcdb08dc5152c04c7b42023-03-28T06:12:09ZfasThe Institute of Islamic Art Studiesهنر اسلامی1735-708X2676-77592022-05-01194539440710.22034/ias.2020.250686.1368127411Adapting the benefits and applications of traditional atriums and circular ceilings, with emphasis on optimizing energy consumption in commercial centers of TehranAmir Shayanian0Fatemeh Mozaffari Qhadikolaei1PhD Student, Department of Architecture, Sari Branch, Islamic Azad University, Sari, IranAssistant Professor, Department of Architecture, Faculty of Engineering, Sari Branch, Islamic Azad University, Sari, IranThis research deals with an efficient approach to achieve energy efficiency optimization solutions with emphasis on the thermal role of atrium in commercial centers in the central part of Tehran and based on simulation. These studies, which are performed with high computational accuracy and dynamic modeling with design builder software, show that the potential for increasing productivity and energy savings in these buildings is very high. One of the main features of this doctoral dissertation is the use of 9 simultaneous variables and the application of a combination of architectural techniques and intelligent technologies in the building based on computer simulation. The research method in this research, according to its nature, is simulation with a case study and analytical approach and in terms of application type. In this research, first, the basic model is validated according to the consumption bills of the desired business center. It is then analyzed by comparing 11 different phases in the software. After applying energy efficiency and building intelligence solutions, it is found that the central atrium in short-level (3 floors), medium-level (5 floors) and then high-rise (13 floors) commercial centers, respectively, better efficiency than the base model without Apply solutions and remove the side walls in these atria, improve natural ventilation in the buildinghttp://www.sysislamicartjournal.ir/article_127411_8d1dd34274e57395e0a89b9a255fa679.pdfoptimizationenergyatriumcommercialtehran
spellingShingle Amir Shayanian
Fatemeh Mozaffari Qhadikolaei
Adapting the benefits and applications of traditional atriums and circular ceilings, with emphasis on optimizing energy consumption in commercial centers of Tehran
هنر اسلامی
optimization
energy
atrium
commercial
tehran
title Adapting the benefits and applications of traditional atriums and circular ceilings, with emphasis on optimizing energy consumption in commercial centers of Tehran
title_full Adapting the benefits and applications of traditional atriums and circular ceilings, with emphasis on optimizing energy consumption in commercial centers of Tehran
title_fullStr Adapting the benefits and applications of traditional atriums and circular ceilings, with emphasis on optimizing energy consumption in commercial centers of Tehran
title_full_unstemmed Adapting the benefits and applications of traditional atriums and circular ceilings, with emphasis on optimizing energy consumption in commercial centers of Tehran
title_short Adapting the benefits and applications of traditional atriums and circular ceilings, with emphasis on optimizing energy consumption in commercial centers of Tehran
title_sort adapting the benefits and applications of traditional atriums and circular ceilings with emphasis on optimizing energy consumption in commercial centers of tehran
topic optimization
energy
atrium
commercial
tehran
url http://www.sysislamicartjournal.ir/article_127411_8d1dd34274e57395e0a89b9a255fa679.pdf
work_keys_str_mv AT amirshayanian adaptingthebenefitsandapplicationsoftraditionalatriumsandcircularceilingswithemphasisonoptimizingenergyconsumptionincommercialcentersoftehran
AT fatemehmozaffariqhadikolaei adaptingthebenefitsandapplicationsoftraditionalatriumsandcircularceilingswithemphasisonoptimizingenergyconsumptionincommercialcentersoftehran