The advanced eccentricity and broken cage diagnostic method for medium voltage induction motors
In the paper the comparative diagnostics of medium voltage induction motors has been presented. The methods employed are the motor current signature analysis (MCSA) and the axial leakage flux spectral analysis. All presented test procedures have been conducted on partially loaded motors, one without...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Electrical Engineering Institute Nikola Tesla
2012-01-01
|
Series: | Zbornik Radova: Elektrotehnički Institut "Nikola Tesla" |
Subjects: | |
Online Access: | http://scindeks-clanci.ceon.rs/data/pdf/0350-8528/2012/0350-85281222235J.pdf |
_version_ | 1818199739378696192 |
---|---|
author | Janda Žarko Janković Marko Milošević Mladen Jovanović Blagota |
author_facet | Janda Žarko Janković Marko Milošević Mladen Jovanović Blagota |
author_sort | Janda Žarko |
collection | DOAJ |
description | In the paper the comparative diagnostics of medium voltage induction motors has been presented. The methods employed are the motor current signature analysis (MCSA) and the axial leakage flux spectral analysis. All presented test procedures have been conducted on partially loaded motors, one without fault and the other with fault. Rated parameters of case study motors are 6 kV and 3.15 MW, and both motors are installed in one combined steam power plant. The reliable broken rotor bars detection and existence of static eccentricity have been demonstrated. The new method for combined fault detection has also been announced. The combined fault under scope is the simultaneous existence of broken rotor bars and static eccentricity. The proposed combined fault detection method is based upon axial leakage flux spectral analysis, especially in the vicinity of the double fundamental frequency. The existence of three broken rotor bars has been confirmed after physical rotor cage examination. |
first_indexed | 2024-12-12T02:26:33Z |
format | Article |
id | doaj.art-f1e6680255444bc5ac356581c0a5ec14 |
institution | Directory Open Access Journal |
issn | 0350-8528 2406-1212 |
language | English |
last_indexed | 2024-12-12T02:26:33Z |
publishDate | 2012-01-01 |
publisher | Electrical Engineering Institute Nikola Tesla |
record_format | Article |
series | Zbornik Radova: Elektrotehnički Institut "Nikola Tesla" |
spelling | doaj.art-f1e6680255444bc5ac356581c0a5ec142022-12-22T00:41:32ZengElectrical Engineering Institute Nikola TeslaZbornik Radova: Elektrotehnički Institut "Nikola Tesla"0350-85282406-12122012-01-0120122223524910.5937/zeint22-29460350-85281222235JThe advanced eccentricity and broken cage diagnostic method for medium voltage induction motorsJanda Žarko0Janković Marko1Milošević Mladen2Jovanović Blagota3University of Belgrade, Electrical Engineering Institute “Nikola Tesla“, Belgrade, Belgrade, SerbiaUniversity of Belgrade, Electrical Engineering Institute “Nikola Tesla“, Belgrade, Belgrade, SerbiaUniversity of Belgrade, Electrical Engineering Institute “Nikola Tesla“, Belgrade, Belgrade, SerbiaUniversity of Belgrade, Electrical Engineering Institute “Nikola Tesla“, Belgrade, Belgrade, SerbiaIn the paper the comparative diagnostics of medium voltage induction motors has been presented. The methods employed are the motor current signature analysis (MCSA) and the axial leakage flux spectral analysis. All presented test procedures have been conducted on partially loaded motors, one without fault and the other with fault. Rated parameters of case study motors are 6 kV and 3.15 MW, and both motors are installed in one combined steam power plant. The reliable broken rotor bars detection and existence of static eccentricity have been demonstrated. The new method for combined fault detection has also been announced. The combined fault under scope is the simultaneous existence of broken rotor bars and static eccentricity. The proposed combined fault detection method is based upon axial leakage flux spectral analysis, especially in the vicinity of the double fundamental frequency. The existence of three broken rotor bars has been confirmed after physical rotor cage examination.http://scindeks-clanci.ceon.rs/data/pdf/0350-8528/2012/0350-85281222235J.pdfinduction motordiagnosticsrotor barstatic eccentricitymotor current spectrumleakage flux spectrum |
spellingShingle | Janda Žarko Janković Marko Milošević Mladen Jovanović Blagota The advanced eccentricity and broken cage diagnostic method for medium voltage induction motors Zbornik Radova: Elektrotehnički Institut "Nikola Tesla" induction motor diagnostics rotor bar static eccentricity motor current spectrum leakage flux spectrum |
title | The advanced eccentricity and broken cage diagnostic method for medium voltage induction motors |
title_full | The advanced eccentricity and broken cage diagnostic method for medium voltage induction motors |
title_fullStr | The advanced eccentricity and broken cage diagnostic method for medium voltage induction motors |
title_full_unstemmed | The advanced eccentricity and broken cage diagnostic method for medium voltage induction motors |
title_short | The advanced eccentricity and broken cage diagnostic method for medium voltage induction motors |
title_sort | advanced eccentricity and broken cage diagnostic method for medium voltage induction motors |
topic | induction motor diagnostics rotor bar static eccentricity motor current spectrum leakage flux spectrum |
url | http://scindeks-clanci.ceon.rs/data/pdf/0350-8528/2012/0350-85281222235J.pdf |
work_keys_str_mv | AT jandazarko theadvancedeccentricityandbrokencagediagnosticmethodformediumvoltageinductionmotors AT jankovicmarko theadvancedeccentricityandbrokencagediagnosticmethodformediumvoltageinductionmotors AT milosevicmladen theadvancedeccentricityandbrokencagediagnosticmethodformediumvoltageinductionmotors AT jovanovicblagota theadvancedeccentricityandbrokencagediagnosticmethodformediumvoltageinductionmotors AT jandazarko advancedeccentricityandbrokencagediagnosticmethodformediumvoltageinductionmotors AT jankovicmarko advancedeccentricityandbrokencagediagnosticmethodformediumvoltageinductionmotors AT milosevicmladen advancedeccentricityandbrokencagediagnosticmethodformediumvoltageinductionmotors AT jovanovicblagota advancedeccentricityandbrokencagediagnosticmethodformediumvoltageinductionmotors |