Research progress in core body temperature measurement during target temperature management
Core body temperature (CBT) is increasingly attracting attention as crucial data during target temperature management (TTM). Accurate and continuous measurement of human CBT can effectively identify and monitor central high fever, and provide a basis for the effective implementation during TTM, whic...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2022-01-01
|
Series: | Journal of Integrative Nursing |
Subjects: | |
Online Access: | http://www.journalin.org/article.asp?issn=2663-4481;year=2022;volume=4;issue=1;spage=36;epage=41;aulast=Liu |
_version_ | 1828733212989325312 |
---|---|
author | Guiying Liu Yanyan Zhang Ling Tang |
author_facet | Guiying Liu Yanyan Zhang Ling Tang |
author_sort | Guiying Liu |
collection | DOAJ |
description | Core body temperature (CBT) is increasingly attracting attention as crucial data during target temperature management (TTM). Accurate and continuous measurement of human CBT can effectively identify and monitor central high fever, and provide a basis for the effective implementation during TTM, which is therefore of great significance for human health care and disease monitoring. The reliable core measurement sites are nasopharynx, esophagus, bladder, rectum, pulmonary artery, etc., but the measurement methods in these sites are all invasive. At present, the medical field is more inclined to noninvasive data collection methods through monitoring an appropriate site (such as forehead, mouth, or axilla) depending on clinical circumstances, so as to ensure the comfort and security of patients to the greatest extent. This review will provide reference choosing more safe and accurate temperature measurement methods for patients during TTM by reviewing the sites and accuracy of invasive and noninvasive CBT measurements. |
first_indexed | 2024-04-12T22:25:40Z |
format | Article |
id | doaj.art-f26477db5c5e4013a571196cc85cb812 |
institution | Directory Open Access Journal |
issn | 2663-4481 |
language | English |
last_indexed | 2024-04-12T22:25:40Z |
publishDate | 2022-01-01 |
publisher | Wolters Kluwer Medknow Publications |
record_format | Article |
series | Journal of Integrative Nursing |
spelling | doaj.art-f26477db5c5e4013a571196cc85cb8122022-12-22T03:14:10ZengWolters Kluwer Medknow PublicationsJournal of Integrative Nursing2663-44812022-01-0141364110.4103/jin.jin_40_21Research progress in core body temperature measurement during target temperature managementGuiying LiuYanyan ZhangLing TangCore body temperature (CBT) is increasingly attracting attention as crucial data during target temperature management (TTM). Accurate and continuous measurement of human CBT can effectively identify and monitor central high fever, and provide a basis for the effective implementation during TTM, which is therefore of great significance for human health care and disease monitoring. The reliable core measurement sites are nasopharynx, esophagus, bladder, rectum, pulmonary artery, etc., but the measurement methods in these sites are all invasive. At present, the medical field is more inclined to noninvasive data collection methods through monitoring an appropriate site (such as forehead, mouth, or axilla) depending on clinical circumstances, so as to ensure the comfort and security of patients to the greatest extent. This review will provide reference choosing more safe and accurate temperature measurement methods for patients during TTM by reviewing the sites and accuracy of invasive and noninvasive CBT measurements.http://www.journalin.org/article.asp?issn=2663-4481;year=2022;volume=4;issue=1;spage=36;epage=41;aulast=Liucore body temperatureneurocritical caretarget temperature management |
spellingShingle | Guiying Liu Yanyan Zhang Ling Tang Research progress in core body temperature measurement during target temperature management Journal of Integrative Nursing core body temperature neurocritical care target temperature management |
title | Research progress in core body temperature measurement during target temperature management |
title_full | Research progress in core body temperature measurement during target temperature management |
title_fullStr | Research progress in core body temperature measurement during target temperature management |
title_full_unstemmed | Research progress in core body temperature measurement during target temperature management |
title_short | Research progress in core body temperature measurement during target temperature management |
title_sort | research progress in core body temperature measurement during target temperature management |
topic | core body temperature neurocritical care target temperature management |
url | http://www.journalin.org/article.asp?issn=2663-4481;year=2022;volume=4;issue=1;spage=36;epage=41;aulast=Liu |
work_keys_str_mv | AT guiyingliu researchprogressincorebodytemperaturemeasurementduringtargettemperaturemanagement AT yanyanzhang researchprogressincorebodytemperaturemeasurementduringtargettemperaturemanagement AT lingtang researchprogressincorebodytemperaturemeasurementduringtargettemperaturemanagement |