Superparamagnetic Iron Oxide–Enhanced Magnetic Resonance Imaging of Neuroinflammation in a Rat Model of Radicular Pain

In many clinical cases of radicular pain, no noticeable neuropathology is detected by conventional medical imaging strategies. Superparamagnetic iron oxide (SPIO) nanoparticles were evaluated as magnetic resonance contrast agents to specifically detect neuroinflammation at sites of painful injury in...

Full description

Bibliographic Details
Main Authors: Daniel L.J. Thorek, Christine L. Weisshaar, Julie C. Czupryna, Beth A. Winkelstein, Andrew Tsourkas
Format: Article
Language:English
Published: SAGE Publications 2011-05-01
Series:Molecular Imaging
Online Access:https://doi.org/10.2310/7290.2010.00042
_version_ 1797285303458725888
author Daniel L.J. Thorek
Christine L. Weisshaar
Julie C. Czupryna
Beth A. Winkelstein
Andrew Tsourkas
author_facet Daniel L.J. Thorek
Christine L. Weisshaar
Julie C. Czupryna
Beth A. Winkelstein
Andrew Tsourkas
author_sort Daniel L.J. Thorek
collection DOAJ
description In many clinical cases of radicular pain, no noticeable neuropathology is detected by conventional medical imaging strategies. Superparamagnetic iron oxide (SPIO) nanoparticles were evaluated as magnetic resonance contrast agents to specifically detect neuroinflammation at sites of painful injury in a rat model of cervical nerve root compression. Two separate groups of rats were used: an injury group that underwent controlled transient compression of the dorsal root and a sham group that received the same surgical procedures but no injury. Precontrast magnetic resonance imaging (MRI) was performed 6 days after surgery, followed by administration of SPIO via tail vein injection. After 24 hours, T 2 * -weighted imaging at the site of root injury revealed a postcontrast enhancement of 72.9 ± 31%. This was significantly greater than that of injured animals prior to SPIO administration (5.3 ± 12.9%). SPIO did not generate any significant postcontrast enhancement in the nerve roots of the sham group. Histology confirmed colocalization of SPIO with macrophage at the injury site. These findings suggest that SPIO-enhanced MRI may be a valuable tool to identify otherwise undetectable nerve root compression and enable improved patient management.
first_indexed 2024-03-07T18:01:12Z
format Article
id doaj.art-f276910f3678411f8216f0eabe3e7378
institution Directory Open Access Journal
issn 1536-0121
language English
last_indexed 2024-03-07T18:01:12Z
publishDate 2011-05-01
publisher SAGE Publications
record_format Article
series Molecular Imaging
spelling doaj.art-f276910f3678411f8216f0eabe3e73782024-03-02T10:53:01ZengSAGE PublicationsMolecular Imaging1536-01212011-05-011010.2310/7290.2010.0004210.2310_7290.2010.00042Superparamagnetic Iron Oxide–Enhanced Magnetic Resonance Imaging of Neuroinflammation in a Rat Model of Radicular PainDaniel L.J. ThorekChristine L. WeisshaarJulie C. CzuprynaBeth A. WinkelsteinAndrew TsourkasIn many clinical cases of radicular pain, no noticeable neuropathology is detected by conventional medical imaging strategies. Superparamagnetic iron oxide (SPIO) nanoparticles were evaluated as magnetic resonance contrast agents to specifically detect neuroinflammation at sites of painful injury in a rat model of cervical nerve root compression. Two separate groups of rats were used: an injury group that underwent controlled transient compression of the dorsal root and a sham group that received the same surgical procedures but no injury. Precontrast magnetic resonance imaging (MRI) was performed 6 days after surgery, followed by administration of SPIO via tail vein injection. After 24 hours, T 2 * -weighted imaging at the site of root injury revealed a postcontrast enhancement of 72.9 ± 31%. This was significantly greater than that of injured animals prior to SPIO administration (5.3 ± 12.9%). SPIO did not generate any significant postcontrast enhancement in the nerve roots of the sham group. Histology confirmed colocalization of SPIO with macrophage at the injury site. These findings suggest that SPIO-enhanced MRI may be a valuable tool to identify otherwise undetectable nerve root compression and enable improved patient management.https://doi.org/10.2310/7290.2010.00042
spellingShingle Daniel L.J. Thorek
Christine L. Weisshaar
Julie C. Czupryna
Beth A. Winkelstein
Andrew Tsourkas
Superparamagnetic Iron Oxide–Enhanced Magnetic Resonance Imaging of Neuroinflammation in a Rat Model of Radicular Pain
Molecular Imaging
title Superparamagnetic Iron Oxide–Enhanced Magnetic Resonance Imaging of Neuroinflammation in a Rat Model of Radicular Pain
title_full Superparamagnetic Iron Oxide–Enhanced Magnetic Resonance Imaging of Neuroinflammation in a Rat Model of Radicular Pain
title_fullStr Superparamagnetic Iron Oxide–Enhanced Magnetic Resonance Imaging of Neuroinflammation in a Rat Model of Radicular Pain
title_full_unstemmed Superparamagnetic Iron Oxide–Enhanced Magnetic Resonance Imaging of Neuroinflammation in a Rat Model of Radicular Pain
title_short Superparamagnetic Iron Oxide–Enhanced Magnetic Resonance Imaging of Neuroinflammation in a Rat Model of Radicular Pain
title_sort superparamagnetic iron oxide enhanced magnetic resonance imaging of neuroinflammation in a rat model of radicular pain
url https://doi.org/10.2310/7290.2010.00042
work_keys_str_mv AT danielljthorek superparamagneticironoxideenhancedmagneticresonanceimagingofneuroinflammationinaratmodelofradicularpain
AT christinelweisshaar superparamagneticironoxideenhancedmagneticresonanceimagingofneuroinflammationinaratmodelofradicularpain
AT juliecczupryna superparamagneticironoxideenhancedmagneticresonanceimagingofneuroinflammationinaratmodelofradicularpain
AT bethawinkelstein superparamagneticironoxideenhancedmagneticresonanceimagingofneuroinflammationinaratmodelofradicularpain
AT andrewtsourkas superparamagneticironoxideenhancedmagneticresonanceimagingofneuroinflammationinaratmodelofradicularpain