OPTIMAL STRUCTURE DESIGN AND TEST ANALYSIS OF PERMANENT MAGNETIC COUPLING FOR DYNAMIC SEALING
In order to achieve dynamic sealing in pressurized vessel considering non-leakage of harmful working medium,this study presents an optimal structure design of permanent magnetic coupling( PMC). For the optimization objective of increasing the torque transmission with limited magnetic material cost a...
Main Authors: | ZHU ZiNa, WU Peng, LAI LeiJie |
---|---|
Format: | Article |
Language: | zho |
Published: |
Editorial Office of Journal of Mechanical Strength
2020-01-01
|
Series: | Jixie qiangdu |
Subjects: | |
Online Access: | http://www.jxqd.net.cn/thesisDetails#10.16579/j.issn.1001.9669.2020.02.014 |
Similar Items
-
Theoretical Computational Model for Cylindrical Permanent Magnet Coupling
by: Ke Sun, et al.
Published: (2021-08-01) -
Analysis of the Partial Demagnetization Process of Magnets in a Line Start Permanent Magnet Synchronous Motor
by: Mariusz Baranski, et al.
Published: (2020-10-01) -
Eddy Current Field Analysis for Permanent Magnetic Governor
by: Xu Wei, et al.
Published: (2015-01-01) -
Suppression of Cross-Coupling Effect of Hybrid Permanent Magnet Synchronous Motor with Parallel Magnetic Circuit
by: Xiao He, et al.
Published: (2021-12-01) -
Analysis of Vibration Characteristic of Radial Permanent Magnet Coupling Under Installation Error
by: Jie Tian, et al.
Published: (2020-01-01)