The Average of Cumulative Radiation Dose in Neonates in the Neonatal Surgery Ward Due to Diagnostic and Therapeutic Radiologic Procedures During the Admission Period

Background: The carcinogenic effect of radiation is directly related to the exposure rate and the risk is even more in infants. The scope of the present study is to evaluate of the average of cumulative radiation dose in neonates in the neonatal surgery ward due to diagnostic and therapeutic radiolo...

Full description

Bibliographic Details
Main Authors: Daryoush Shahbazi-Gahrouei, Masoud Nazem, Mohammad Sharbafchizadeh, Mohmmad Saleh Jafarpishehfard
Format: Article
Language:fas
Published: Isfahan University of Medical Sciences 2011-07-01
Series:مجله دانشکده پزشکی اصفهان
Subjects:
Online Access:http://jims.mui.ac.ir/index.php/jims/article/view/406
_version_ 1797720595407831040
author Daryoush Shahbazi-Gahrouei
Masoud Nazem
Mohammad Sharbafchizadeh
Mohmmad Saleh Jafarpishehfard
author_facet Daryoush Shahbazi-Gahrouei
Masoud Nazem
Mohammad Sharbafchizadeh
Mohmmad Saleh Jafarpishehfard
author_sort Daryoush Shahbazi-Gahrouei
collection DOAJ
description Background: The carcinogenic effect of radiation is directly related to the exposure rate and the risk is even more in infants. The scope of the present study is to evaluate of the average of cumulative radiation dose in neonates in the neonatal surgery ward due to diagnostic and therapeutic radiologic procedures during the admission period, in Alzahra hospital of Isfahan, Iran. Methods: This investigation was a descriptive study on 168 neonates. It was done in neonatal surgery ward during last 9 months of 2009 in Alzahra hospital of Isfahan, Iran. The patients were selected randomly and with no attention to age, sex, diagnose and admision time. Thermo luminescent dosimeters (TLD GR200), were used for dosimetry and each chips was putted in a plastic envelope on the neonate sternum during the admission period. The cumulative absorbed dose by each patient was stored during the admission by TLD and followed by reading by TLD reader. For using of TLDs, they were calibrated and two calibration factors (individual and batch) were performed in radiotherapy section of Seyed Al-shohada hospital of Isfahan, Iran. After checking the accuracy of calibration, the absorbed dose by each patient was achieved by using of calibration factors. Finding: The average of admission time for each patient was 7.64 days and the average of cumulative absorbed dose was 3.13 Millisievert (mSv) during this time. The maximum absorbed dose in one patient was 42.83 mSv. The average number of conventional radiography for each patient was 2.77. The average of conventional radiography and cumulative absorbed dose in patient with no examination or just simple x-ray examinations was 2.58 and 0.863 mSv, respectively. Chest x-ray examination was the most examination used here (338 person). The average dose for each chest x-ray examination was 0.313 mSv. The average of cumulative absorbed dose among patients with fluoroscopic examination was about 12.6 mSv. The cumulative absorbed dose in 19 patients was more than 10 mSv. Conclusion: The average of cumulative absorbed dose was not more than the dose limit according to reference levels, but in comparison with other medical centers in the world is very high. Therefore, it is necessary to pay more attention to reduce radiological imaging procedures, particularly about fluoroscopic procedures.
first_indexed 2024-03-12T09:22:44Z
format Article
id doaj.art-f2dd203abe9042db8513c5a29e49dd43
institution Directory Open Access Journal
issn 1027-7595
1735-854X
language fas
last_indexed 2024-03-12T09:22:44Z
publishDate 2011-07-01
publisher Isfahan University of Medical Sciences
record_format Article
series مجله دانشکده پزشکی اصفهان
spelling doaj.art-f2dd203abe9042db8513c5a29e49dd432023-09-02T14:27:22ZfasIsfahan University of Medical Sciencesمجله دانشکده پزشکی اصفهان1027-75951735-854X2011-07-0129140626633682The Average of Cumulative Radiation Dose in Neonates in the Neonatal Surgery Ward Due to Diagnostic and Therapeutic Radiologic Procedures During the Admission PeriodDaryoush Shahbazi-Gahrouei0Masoud Nazem1Mohammad Sharbafchizadeh2Mohmmad Saleh Jafarpishehfard3Professor, Department of Medical Physics and Medical Engineering, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.Associate Professor, Department of Pediatrics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.Student of Medicine, Student Research Committee, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.Student of Medicine, Student Research Committee, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.Background: The carcinogenic effect of radiation is directly related to the exposure rate and the risk is even more in infants. The scope of the present study is to evaluate of the average of cumulative radiation dose in neonates in the neonatal surgery ward due to diagnostic and therapeutic radiologic procedures during the admission period, in Alzahra hospital of Isfahan, Iran. Methods: This investigation was a descriptive study on 168 neonates. It was done in neonatal surgery ward during last 9 months of 2009 in Alzahra hospital of Isfahan, Iran. The patients were selected randomly and with no attention to age, sex, diagnose and admision time. Thermo luminescent dosimeters (TLD GR200), were used for dosimetry and each chips was putted in a plastic envelope on the neonate sternum during the admission period. The cumulative absorbed dose by each patient was stored during the admission by TLD and followed by reading by TLD reader. For using of TLDs, they were calibrated and two calibration factors (individual and batch) were performed in radiotherapy section of Seyed Al-shohada hospital of Isfahan, Iran. After checking the accuracy of calibration, the absorbed dose by each patient was achieved by using of calibration factors. Finding: The average of admission time for each patient was 7.64 days and the average of cumulative absorbed dose was 3.13 Millisievert (mSv) during this time. The maximum absorbed dose in one patient was 42.83 mSv. The average number of conventional radiography for each patient was 2.77. The average of conventional radiography and cumulative absorbed dose in patient with no examination or just simple x-ray examinations was 2.58 and 0.863 mSv, respectively. Chest x-ray examination was the most examination used here (338 person). The average dose for each chest x-ray examination was 0.313 mSv. The average of cumulative absorbed dose among patients with fluoroscopic examination was about 12.6 mSv. The cumulative absorbed dose in 19 patients was more than 10 mSv. Conclusion: The average of cumulative absorbed dose was not more than the dose limit according to reference levels, but in comparison with other medical centers in the world is very high. Therefore, it is necessary to pay more attention to reduce radiological imaging procedures, particularly about fluoroscopic procedures.http://jims.mui.ac.ir/index.php/jims/article/view/406X-rayCumulative doseConventional radiographyFluoroscopy
spellingShingle Daryoush Shahbazi-Gahrouei
Masoud Nazem
Mohammad Sharbafchizadeh
Mohmmad Saleh Jafarpishehfard
The Average of Cumulative Radiation Dose in Neonates in the Neonatal Surgery Ward Due to Diagnostic and Therapeutic Radiologic Procedures During the Admission Period
مجله دانشکده پزشکی اصفهان
X-ray
Cumulative dose
Conventional radiography
Fluoroscopy
title The Average of Cumulative Radiation Dose in Neonates in the Neonatal Surgery Ward Due to Diagnostic and Therapeutic Radiologic Procedures During the Admission Period
title_full The Average of Cumulative Radiation Dose in Neonates in the Neonatal Surgery Ward Due to Diagnostic and Therapeutic Radiologic Procedures During the Admission Period
title_fullStr The Average of Cumulative Radiation Dose in Neonates in the Neonatal Surgery Ward Due to Diagnostic and Therapeutic Radiologic Procedures During the Admission Period
title_full_unstemmed The Average of Cumulative Radiation Dose in Neonates in the Neonatal Surgery Ward Due to Diagnostic and Therapeutic Radiologic Procedures During the Admission Period
title_short The Average of Cumulative Radiation Dose in Neonates in the Neonatal Surgery Ward Due to Diagnostic and Therapeutic Radiologic Procedures During the Admission Period
title_sort average of cumulative radiation dose in neonates in the neonatal surgery ward due to diagnostic and therapeutic radiologic procedures during the admission period
topic X-ray
Cumulative dose
Conventional radiography
Fluoroscopy
url http://jims.mui.ac.ir/index.php/jims/article/view/406
work_keys_str_mv AT daryoushshahbazigahrouei theaverageofcumulativeradiationdoseinneonatesintheneonatalsurgerywardduetodiagnosticandtherapeuticradiologicproceduresduringtheadmissionperiod
AT masoudnazem theaverageofcumulativeradiationdoseinneonatesintheneonatalsurgerywardduetodiagnosticandtherapeuticradiologicproceduresduringtheadmissionperiod
AT mohammadsharbafchizadeh theaverageofcumulativeradiationdoseinneonatesintheneonatalsurgerywardduetodiagnosticandtherapeuticradiologicproceduresduringtheadmissionperiod
AT mohmmadsalehjafarpishehfard theaverageofcumulativeradiationdoseinneonatesintheneonatalsurgerywardduetodiagnosticandtherapeuticradiologicproceduresduringtheadmissionperiod
AT daryoushshahbazigahrouei averageofcumulativeradiationdoseinneonatesintheneonatalsurgerywardduetodiagnosticandtherapeuticradiologicproceduresduringtheadmissionperiod
AT masoudnazem averageofcumulativeradiationdoseinneonatesintheneonatalsurgerywardduetodiagnosticandtherapeuticradiologicproceduresduringtheadmissionperiod
AT mohammadsharbafchizadeh averageofcumulativeradiationdoseinneonatesintheneonatalsurgerywardduetodiagnosticandtherapeuticradiologicproceduresduringtheadmissionperiod
AT mohmmadsalehjafarpishehfard averageofcumulativeradiationdoseinneonatesintheneonatalsurgerywardduetodiagnosticandtherapeuticradiologicproceduresduringtheadmissionperiod