Is It Possible to Supply Norwegian Apartment Blocks with 4th Generation District Heating?
Direct electricity is widely used for heating purposes in Norway, leading to significant strain on the electricity grid during the heating season. Conversion to 4th generation district heating (4GDH) is an effective method for reducing the need for large investments in the electricity grid, while si...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2019-03-01
|
Series: | Energies |
Subjects: | |
Online Access: | http://www.mdpi.com/1996-1073/12/5/941 |
_version_ | 1798035351510450176 |
---|---|
author | Øystein Rønneseth Nina Holck Sandberg Igor Sartori |
author_facet | Øystein Rønneseth Nina Holck Sandberg Igor Sartori |
author_sort | Øystein Rønneseth |
collection | DOAJ |
description | Direct electricity is widely used for heating purposes in Norway, leading to significant strain on the electricity grid during the heating season. Conversion to 4th generation district heating (4GDH) is an effective method for reducing the need for large investments in the electricity grid, while simultaneously improving the energy efficiency of district heating systems. This article evaluates the possibility of reducing the supply temperature in existing Norwegian apartment blocks by improving the thermal envelope and reducing the temperature levels for the heating system. The analysis is based on simulations in IDA ICE (IDA Indoor Climate and Energy) focusing on whether the reduced supply temperature guarantees thermal comfort in the building, considering the coldest room with a heating setpoint of 22 °C. Based on a recommended minimum acceptable indoor temperature of 19 °C from the Norwegian building regulations (TEK), it should be possible to lower the radiator supply temperature from 80 to 60 °C for apartment blocks newer than 1971. For older buildings, an “intermediate” renovation is necessary to maintain temperatures above 19 °C, however, a “standard” renovation is recommended to ensure thermal comfort and improve the energy efficiency of the building stock. |
first_indexed | 2024-04-11T20:56:04Z |
format | Article |
id | doaj.art-f2ff3b33a9bf45c498fdad56d2eea34a |
institution | Directory Open Access Journal |
issn | 1996-1073 |
language | English |
last_indexed | 2024-04-11T20:56:04Z |
publishDate | 2019-03-01 |
publisher | MDPI AG |
record_format | Article |
series | Energies |
spelling | doaj.art-f2ff3b33a9bf45c498fdad56d2eea34a2022-12-22T04:03:40ZengMDPI AGEnergies1996-10732019-03-0112594110.3390/en12050941en12050941Is It Possible to Supply Norwegian Apartment Blocks with 4th Generation District Heating?Øystein Rønneseth0Nina Holck Sandberg1Igor Sartori2SINTEF Building and Infrastructure, Høgskoleringen 7B, 7034 Trondheim, NorwayNorwegian University of Science and Technology (NTNU), Department of Energy and Process Engineering, Kolbjørn Hejes vei 1B, 7034 Trondheim, NorwaySINTEF Building and Infrastructure, Forskningsveien 3B, 0373 Oslo, NorwayDirect electricity is widely used for heating purposes in Norway, leading to significant strain on the electricity grid during the heating season. Conversion to 4th generation district heating (4GDH) is an effective method for reducing the need for large investments in the electricity grid, while simultaneously improving the energy efficiency of district heating systems. This article evaluates the possibility of reducing the supply temperature in existing Norwegian apartment blocks by improving the thermal envelope and reducing the temperature levels for the heating system. The analysis is based on simulations in IDA ICE (IDA Indoor Climate and Energy) focusing on whether the reduced supply temperature guarantees thermal comfort in the building, considering the coldest room with a heating setpoint of 22 °C. Based on a recommended minimum acceptable indoor temperature of 19 °C from the Norwegian building regulations (TEK), it should be possible to lower the radiator supply temperature from 80 to 60 °C for apartment blocks newer than 1971. For older buildings, an “intermediate” renovation is necessary to maintain temperatures above 19 °C, however, a “standard” renovation is recommended to ensure thermal comfort and improve the energy efficiency of the building stock.http://www.mdpi.com/1996-1073/12/5/941district heatingheating demandapartment blockstemperature requirementenergy renovationexisting building stock |
spellingShingle | Øystein Rønneseth Nina Holck Sandberg Igor Sartori Is It Possible to Supply Norwegian Apartment Blocks with 4th Generation District Heating? Energies district heating heating demand apartment blocks temperature requirement energy renovation existing building stock |
title | Is It Possible to Supply Norwegian Apartment Blocks with 4th Generation District Heating? |
title_full | Is It Possible to Supply Norwegian Apartment Blocks with 4th Generation District Heating? |
title_fullStr | Is It Possible to Supply Norwegian Apartment Blocks with 4th Generation District Heating? |
title_full_unstemmed | Is It Possible to Supply Norwegian Apartment Blocks with 4th Generation District Heating? |
title_short | Is It Possible to Supply Norwegian Apartment Blocks with 4th Generation District Heating? |
title_sort | is it possible to supply norwegian apartment blocks with 4th generation district heating |
topic | district heating heating demand apartment blocks temperature requirement energy renovation existing building stock |
url | http://www.mdpi.com/1996-1073/12/5/941 |
work_keys_str_mv | AT øysteinrønneseth isitpossibletosupplynorwegianapartmentblockswith4thgenerationdistrictheating AT ninaholcksandberg isitpossibletosupplynorwegianapartmentblockswith4thgenerationdistrictheating AT igorsartori isitpossibletosupplynorwegianapartmentblockswith4thgenerationdistrictheating |