Alternative pre-analytic sample handling techniques for glucose measurement in the absence of fluoride tubes in low resource settings.

<h4>Introduction</h4>Sodium fluoride (NaF) tubes are the recommended tubes for glucose measurements, but these are expensive, have limited number of uses, and are not always available in low resource settings. Alternative sample handling techniques are thus needed. We compared glucose st...

Full description

Bibliographic Details
Main Authors: Wisdom P Nakanga, Priscilla Balungi, Anxious J Niwaha, Beverly M Shields, Peter Hughes, Rob C Andrews, Tim J Mc Donald, Moffat J Nyirenda, Andrew T Hattersley
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2022-01-01
Series:PLoS ONE
Online Access:https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0264432&type=printable
_version_ 1797221667686055936
author Wisdom P Nakanga
Priscilla Balungi
Anxious J Niwaha
Beverly M Shields
Peter Hughes
Rob C Andrews
Tim J Mc Donald
Moffat J Nyirenda
Andrew T Hattersley
author_facet Wisdom P Nakanga
Priscilla Balungi
Anxious J Niwaha
Beverly M Shields
Peter Hughes
Rob C Andrews
Tim J Mc Donald
Moffat J Nyirenda
Andrew T Hattersley
author_sort Wisdom P Nakanga
collection DOAJ
description <h4>Introduction</h4>Sodium fluoride (NaF) tubes are the recommended tubes for glucose measurements, but these are expensive, have limited number of uses, and are not always available in low resource settings. Alternative sample handling techniques are thus needed. We compared glucose stability in samples collected in various tubes exposed to different pre-analytical conditions in Uganda.<h4>Methods</h4>Random (non-fasted) blood samples were drawn from nine healthy participants into NaF, Ethylenediaminetetraacetic acid (EDTA), and plain serum tubes. The samples were kept un-centrifuged or centrifuged with plasma or serum pipetted into aliquots, placed in cool box with ice or at room temperature and were stored in a permanent freezer after 0, 2, 6, 12 and 24 hours post blood draw before glucose analysis.<h4>Results</h4>Rapid decline in glucose concentrations was observed when compared to baseline in serum (declined to 64%) and EDTA-plasma (declined to 77%) after 6 hours when samples were un-centrifuged at room temperature whilst NaF-plasma was stable after 24 hours in the same condition. Un-centrifuged EDTA-plasma kept on ice was stable for up to 6 hours but serum was not stable (degraded to 92%) in the same conditions. Early centrifugation prevented glucose decline even at room temperature regardless of the primary tube used with serum, EDTA-plasma and NaF-plasma after 24 hours.<h4>Conclusion</h4>In low resource settings we recommend use of EDTA tubes placed in cool box with ice and analysed within 6 hours as an alternative to NaF tubes. Alternatively, immediate separation of blood with manual hand centrifuges will allow any tube to be used even in remote settings with no electricity.
first_indexed 2024-04-24T13:09:05Z
format Article
id doaj.art-f300cadbac6648a5b8d43aa0b36d313d
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-04-24T13:09:05Z
publishDate 2022-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-f300cadbac6648a5b8d43aa0b36d313d2024-04-05T05:34:44ZengPublic Library of Science (PLoS)PLoS ONE1932-62032022-01-01172e026443210.1371/journal.pone.0264432Alternative pre-analytic sample handling techniques for glucose measurement in the absence of fluoride tubes in low resource settings.Wisdom P NakangaPriscilla BalungiAnxious J NiwahaBeverly M ShieldsPeter HughesRob C AndrewsTim J Mc DonaldMoffat J NyirendaAndrew T Hattersley<h4>Introduction</h4>Sodium fluoride (NaF) tubes are the recommended tubes for glucose measurements, but these are expensive, have limited number of uses, and are not always available in low resource settings. Alternative sample handling techniques are thus needed. We compared glucose stability in samples collected in various tubes exposed to different pre-analytical conditions in Uganda.<h4>Methods</h4>Random (non-fasted) blood samples were drawn from nine healthy participants into NaF, Ethylenediaminetetraacetic acid (EDTA), and plain serum tubes. The samples were kept un-centrifuged or centrifuged with plasma or serum pipetted into aliquots, placed in cool box with ice or at room temperature and were stored in a permanent freezer after 0, 2, 6, 12 and 24 hours post blood draw before glucose analysis.<h4>Results</h4>Rapid decline in glucose concentrations was observed when compared to baseline in serum (declined to 64%) and EDTA-plasma (declined to 77%) after 6 hours when samples were un-centrifuged at room temperature whilst NaF-plasma was stable after 24 hours in the same condition. Un-centrifuged EDTA-plasma kept on ice was stable for up to 6 hours but serum was not stable (degraded to 92%) in the same conditions. Early centrifugation prevented glucose decline even at room temperature regardless of the primary tube used with serum, EDTA-plasma and NaF-plasma after 24 hours.<h4>Conclusion</h4>In low resource settings we recommend use of EDTA tubes placed in cool box with ice and analysed within 6 hours as an alternative to NaF tubes. Alternatively, immediate separation of blood with manual hand centrifuges will allow any tube to be used even in remote settings with no electricity.https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0264432&type=printable
spellingShingle Wisdom P Nakanga
Priscilla Balungi
Anxious J Niwaha
Beverly M Shields
Peter Hughes
Rob C Andrews
Tim J Mc Donald
Moffat J Nyirenda
Andrew T Hattersley
Alternative pre-analytic sample handling techniques for glucose measurement in the absence of fluoride tubes in low resource settings.
PLoS ONE
title Alternative pre-analytic sample handling techniques for glucose measurement in the absence of fluoride tubes in low resource settings.
title_full Alternative pre-analytic sample handling techniques for glucose measurement in the absence of fluoride tubes in low resource settings.
title_fullStr Alternative pre-analytic sample handling techniques for glucose measurement in the absence of fluoride tubes in low resource settings.
title_full_unstemmed Alternative pre-analytic sample handling techniques for glucose measurement in the absence of fluoride tubes in low resource settings.
title_short Alternative pre-analytic sample handling techniques for glucose measurement in the absence of fluoride tubes in low resource settings.
title_sort alternative pre analytic sample handling techniques for glucose measurement in the absence of fluoride tubes in low resource settings
url https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0264432&type=printable
work_keys_str_mv AT wisdompnakanga alternativepreanalyticsamplehandlingtechniquesforglucosemeasurementintheabsenceoffluoridetubesinlowresourcesettings
AT priscillabalungi alternativepreanalyticsamplehandlingtechniquesforglucosemeasurementintheabsenceoffluoridetubesinlowresourcesettings
AT anxiousjniwaha alternativepreanalyticsamplehandlingtechniquesforglucosemeasurementintheabsenceoffluoridetubesinlowresourcesettings
AT beverlymshields alternativepreanalyticsamplehandlingtechniquesforglucosemeasurementintheabsenceoffluoridetubesinlowresourcesettings
AT peterhughes alternativepreanalyticsamplehandlingtechniquesforglucosemeasurementintheabsenceoffluoridetubesinlowresourcesettings
AT robcandrews alternativepreanalyticsamplehandlingtechniquesforglucosemeasurementintheabsenceoffluoridetubesinlowresourcesettings
AT timjmcdonald alternativepreanalyticsamplehandlingtechniquesforglucosemeasurementintheabsenceoffluoridetubesinlowresourcesettings
AT moffatjnyirenda alternativepreanalyticsamplehandlingtechniquesforglucosemeasurementintheabsenceoffluoridetubesinlowresourcesettings
AT andrewthattersley alternativepreanalyticsamplehandlingtechniquesforglucosemeasurementintheabsenceoffluoridetubesinlowresourcesettings