High-Throughput Analysis of Offshore Well Drill-Cuttings via SEM-Automated Mineralogy Using Single-Step Trans-Vertical Moulds

Single-step trans-vertical moulds used to prepare grain mounts for SEM-automated-mineralogy based instruments have been shown to lead to more representative sample statistics. For samples that contain a variety of mineral phases, denser phases can settle to the bottom of an epoxy mould during the cu...

Full description

Bibliographic Details
Main Authors: David Grant, Dylan J. Goudie, Derek Wilton
Format: Article
Language:English
Published: MDPI AG 2022-03-01
Series:Minerals
Subjects:
Online Access:https://www.mdpi.com/2075-163X/12/3/337
_version_ 1797444609467482112
author David Grant
Dylan J. Goudie
Derek Wilton
author_facet David Grant
Dylan J. Goudie
Derek Wilton
author_sort David Grant
collection DOAJ
description Single-step trans-vertical moulds used to prepare grain mounts for SEM-automated-mineralogy based instruments have been shown to lead to more representative sample statistics. For samples that contain a variety of mineral phases, denser phases can settle to the bottom of an epoxy mould during the curing phase. Slicing and polishing a cross section through density-stratified moulds of the sample material can compensate for this. Aliquots from offshore drill well cuttings were prepared using three different methods: (1) traditional epoxy mounting, (2) two-step trans-vertical moulds, and (3) single-step trans-vertical moulds. All were analysed with a FEI Quanta 650 FEG instrument using MLA software with similar acquisition parameters. The results indicate that the single-step trans-vertical moulds are reproducible, lead to more accurate statistics, and yield MLA calculated elemental assays that closely match with data from standard analytical methods. In addition, these moulds can be made in half the time of the two-step trans-vertical moulds, and because of the unique geometry of the custom-made SEM holders, the analytical throughput is doubled. Depending on the size fraction of the well cuttings, the throughput can be further increased by slicing off the remaining epoxy to allow for more samples in the 26x TV holder. A unique cell holder was created to accommodate these trans-vertical samples, allowing them to fit into a LA-ICP-MS instrument such that detailed follow-up microanalyses can be conducted on specific minerals. For instance geochronology can be conducted on grains of interest (e.g., zircons), which had been mapped by the SEM-MLA.
first_indexed 2024-03-09T13:14:06Z
format Article
id doaj.art-f3552cd64f1c4b81bd1c173e6107a0e5
institution Directory Open Access Journal
issn 2075-163X
language English
last_indexed 2024-03-09T13:14:06Z
publishDate 2022-03-01
publisher MDPI AG
record_format Article
series Minerals
spelling doaj.art-f3552cd64f1c4b81bd1c173e6107a0e52023-11-30T21:38:43ZengMDPI AGMinerals2075-163X2022-03-0112333710.3390/min12030337High-Throughput Analysis of Offshore Well Drill-Cuttings via SEM-Automated Mineralogy Using Single-Step Trans-Vertical MouldsDavid Grant0Dylan J. Goudie1Derek Wilton2Core Research Equipment and Instrument Training Network (CREAIT), Memorial University of Newfoundland, St. John’s, NL A1C 5S7, CanadaCore Research Equipment and Instrument Training Network (CREAIT), Memorial University of Newfoundland, St. John’s, NL A1C 5S7, CanadaDepartment of Earth Sciences, Memorial University of Newfoundland, St. John’s, NL A1C 5S7, CanadaSingle-step trans-vertical moulds used to prepare grain mounts for SEM-automated-mineralogy based instruments have been shown to lead to more representative sample statistics. For samples that contain a variety of mineral phases, denser phases can settle to the bottom of an epoxy mould during the curing phase. Slicing and polishing a cross section through density-stratified moulds of the sample material can compensate for this. Aliquots from offshore drill well cuttings were prepared using three different methods: (1) traditional epoxy mounting, (2) two-step trans-vertical moulds, and (3) single-step trans-vertical moulds. All were analysed with a FEI Quanta 650 FEG instrument using MLA software with similar acquisition parameters. The results indicate that the single-step trans-vertical moulds are reproducible, lead to more accurate statistics, and yield MLA calculated elemental assays that closely match with data from standard analytical methods. In addition, these moulds can be made in half the time of the two-step trans-vertical moulds, and because of the unique geometry of the custom-made SEM holders, the analytical throughput is doubled. Depending on the size fraction of the well cuttings, the throughput can be further increased by slicing off the remaining epoxy to allow for more samples in the 26x TV holder. A unique cell holder was created to accommodate these trans-vertical samples, allowing them to fit into a LA-ICP-MS instrument such that detailed follow-up microanalyses can be conducted on specific minerals. For instance geochronology can be conducted on grains of interest (e.g., zircons), which had been mapped by the SEM-MLA.https://www.mdpi.com/2075-163X/12/3/337scanning electron microscopemineral liberation analysisautomated mineralogy sample preparationparticle sizing
spellingShingle David Grant
Dylan J. Goudie
Derek Wilton
High-Throughput Analysis of Offshore Well Drill-Cuttings via SEM-Automated Mineralogy Using Single-Step Trans-Vertical Moulds
Minerals
scanning electron microscope
mineral liberation analysis
automated mineralogy sample preparation
particle sizing
title High-Throughput Analysis of Offshore Well Drill-Cuttings via SEM-Automated Mineralogy Using Single-Step Trans-Vertical Moulds
title_full High-Throughput Analysis of Offshore Well Drill-Cuttings via SEM-Automated Mineralogy Using Single-Step Trans-Vertical Moulds
title_fullStr High-Throughput Analysis of Offshore Well Drill-Cuttings via SEM-Automated Mineralogy Using Single-Step Trans-Vertical Moulds
title_full_unstemmed High-Throughput Analysis of Offshore Well Drill-Cuttings via SEM-Automated Mineralogy Using Single-Step Trans-Vertical Moulds
title_short High-Throughput Analysis of Offshore Well Drill-Cuttings via SEM-Automated Mineralogy Using Single-Step Trans-Vertical Moulds
title_sort high throughput analysis of offshore well drill cuttings via sem automated mineralogy using single step trans vertical moulds
topic scanning electron microscope
mineral liberation analysis
automated mineralogy sample preparation
particle sizing
url https://www.mdpi.com/2075-163X/12/3/337
work_keys_str_mv AT davidgrant highthroughputanalysisofoffshorewelldrillcuttingsviasemautomatedmineralogyusingsinglesteptransverticalmoulds
AT dylanjgoudie highthroughputanalysisofoffshorewelldrillcuttingsviasemautomatedmineralogyusingsinglesteptransverticalmoulds
AT derekwilton highthroughputanalysisofoffshorewelldrillcuttingsviasemautomatedmineralogyusingsinglesteptransverticalmoulds