Discussion on energy saving optimization of supercritical secondary reheat unit
It aimed at the secondary reheat ultra-supercritical unit to study the direction of energy saving, through comparing the design reasonable optimization and energy saving, improve the cycle thermal efficiency, reduce the coal consumption, achieve the goal of saving energy and reducing consumption. Fr...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2022-01-01
|
Series: | ITM Web of Conferences |
Subjects: | |
Online Access: | https://www.itm-conferences.org/articles/itmconf/pdf/2022/07/itmconf_cccar2022_03043.pdf |
_version_ | 1811329805228965888 |
---|---|
author | Li Wei Jia Changwu Ma Kuiyuan Cong Ming Chen Zenghui |
author_facet | Li Wei Jia Changwu Ma Kuiyuan Cong Ming Chen Zenghui |
author_sort | Li Wei |
collection | DOAJ |
description | It aimed at the secondary reheat ultra-supercritical unit to study the direction of energy saving, through comparing the design reasonable optimization and energy saving, improve the cycle thermal efficiency, reduce the coal consumption, achieve the goal of saving energy and reducing consumption. From the traditional heat extraction scheme, by setting the cooler, increase the heat series to design a new solution method, such as energy saving optimization scheme of different performance, investment, such as comparative analysis, finally to determine the best solution. Through the design of a series of studies show that for secondary reheat ultra-supercritical unit, can adopt the following means to improve the efficiency of generating units: one is to increase external steam cooler, make full use of the extraction period of heat; The second is to increase the steam recovery series and rationally distribute the enthalpy drops at all levels. After the above energy-saving optimization and transformation technology, the generating efficiency of the unit is increased by 1.6%, and the coal consumption of power supply is reduced by 6.6g/kWh, achieving a good energy-saving effect. |
first_indexed | 2024-04-13T15:50:23Z |
format | Article |
id | doaj.art-f488be2c3459474cb46ff55fe3066199 |
institution | Directory Open Access Journal |
issn | 2271-2097 |
language | English |
last_indexed | 2024-04-13T15:50:23Z |
publishDate | 2022-01-01 |
publisher | EDP Sciences |
record_format | Article |
series | ITM Web of Conferences |
spelling | doaj.art-f488be2c3459474cb46ff55fe30661992022-12-22T02:40:52ZengEDP SciencesITM Web of Conferences2271-20972022-01-01470304310.1051/itmconf/20224703043itmconf_cccar2022_03043Discussion on energy saving optimization of supercritical secondary reheat unitLi Wei0Jia Changwu1Ma Kuiyuan2Cong Ming3Chen Zenghui4Datang Dongying Power Generation Co. LtdDatang Dongying Power Generation Co. LtdDatang Northeast Electric Power Test Research Institute Co. LtdDatang Northeast Electric Power Test Research Institute Co. LtdDatang Dongying Power Generation Co. LtdIt aimed at the secondary reheat ultra-supercritical unit to study the direction of energy saving, through comparing the design reasonable optimization and energy saving, improve the cycle thermal efficiency, reduce the coal consumption, achieve the goal of saving energy and reducing consumption. From the traditional heat extraction scheme, by setting the cooler, increase the heat series to design a new solution method, such as energy saving optimization scheme of different performance, investment, such as comparative analysis, finally to determine the best solution. Through the design of a series of studies show that for secondary reheat ultra-supercritical unit, can adopt the following means to improve the efficiency of generating units: one is to increase external steam cooler, make full use of the extraction period of heat; The second is to increase the steam recovery series and rationally distribute the enthalpy drops at all levels. After the above energy-saving optimization and transformation technology, the generating efficiency of the unit is increased by 1.6%, and the coal consumption of power supply is reduced by 6.6g/kWh, achieving a good energy-saving effect.https://www.itm-conferences.org/articles/itmconf/pdf/2022/07/itmconf_cccar2022_03043.pdfsecondary reheatthermal systemexternal steam cooleroptimization of regenerative seriesenergy saving effect |
spellingShingle | Li Wei Jia Changwu Ma Kuiyuan Cong Ming Chen Zenghui Discussion on energy saving optimization of supercritical secondary reheat unit ITM Web of Conferences secondary reheat thermal system external steam cooler optimization of regenerative series energy saving effect |
title | Discussion on energy saving optimization of supercritical secondary reheat unit |
title_full | Discussion on energy saving optimization of supercritical secondary reheat unit |
title_fullStr | Discussion on energy saving optimization of supercritical secondary reheat unit |
title_full_unstemmed | Discussion on energy saving optimization of supercritical secondary reheat unit |
title_short | Discussion on energy saving optimization of supercritical secondary reheat unit |
title_sort | discussion on energy saving optimization of supercritical secondary reheat unit |
topic | secondary reheat thermal system external steam cooler optimization of regenerative series energy saving effect |
url | https://www.itm-conferences.org/articles/itmconf/pdf/2022/07/itmconf_cccar2022_03043.pdf |
work_keys_str_mv | AT liwei discussiononenergysavingoptimizationofsupercriticalsecondaryreheatunit AT jiachangwu discussiononenergysavingoptimizationofsupercriticalsecondaryreheatunit AT makuiyuan discussiononenergysavingoptimizationofsupercriticalsecondaryreheatunit AT congming discussiononenergysavingoptimizationofsupercriticalsecondaryreheatunit AT chenzenghui discussiononenergysavingoptimizationofsupercriticalsecondaryreheatunit |