Research on the Lightning Intruding Overvoltage and Protection Measures of 500 kV AC Fault Current Limiter
As one of the key technologies to solve the problem of high short-circuit current, the fault current limiter (FCL) has become a research hotspot in China and abroad. The overvoltage and protection measures of the FCL are the key technologies for its application. Therefore, this paper studies the lig...
Main Authors: | , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2019-10-01
|
Series: | Energies |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1073/12/20/3845 |
_version_ | 1798006638521614336 |
---|---|
author | Changfu Chen Yongxia Han Junxiang Liu Wenxiong Mo Zhao Yuan Jianning Huang Haibo Su Xiancong Zhang Kaijian Wu |
author_facet | Changfu Chen Yongxia Han Junxiang Liu Wenxiong Mo Zhao Yuan Jianning Huang Haibo Su Xiancong Zhang Kaijian Wu |
author_sort | Changfu Chen |
collection | DOAJ |
description | As one of the key technologies to solve the problem of high short-circuit current, the fault current limiter (FCL) has become a research hotspot in China and abroad. The overvoltage and protection measures of the FCL are the key technologies for its application. Therefore, this paper studies the lightning intruding overvoltage and protection measures for a 500 kV FCL based on a high coupled split reactor (HCSR). Firstly, according to the main topology of the system and the 500 kV HCSR-FCL structure, the lightning intruding overvoltage simulation model of the 500 kV station, including the nearby transmission lines, is established on the PSCAD (Power Systems Computer Aided Design) program. Secondly, the lightning overvoltage of the equipment in the station and the components of the HCSR-FCL are simulated and analyzed when the transmission lines nearby are subjected to lightning shielding failure and back flashover. Meanwhile, the influence of the HCSR-FCL on the lightning overvoltage of the equipment in the station are compared and analyzed before and after the HCSR-FCL is installed. The simulation results show that the overvoltage of the equipment in the station and the components of the HCSR-FCL is more serious when the shielding failure occurs in the transmission lines nearby. The HCSR-FCL can reduce the lightning overvoltage of the equipment in the station, but the maximum inter-terminal and inter-arm lightning overvoltage of the HCSR can reach 1064 kV and 790 kV, respectively, under the current limiting state and the current sharing state. Finally, methods of increasing the arresters on the transmission lines side of the HCSR-FCL and shunt capacitor between each module of the HCSR-FCL are proposed to reduce the lightning overvoltage. The lightning impulse withstand voltage of each component of the HCSR is also proposed: The inter-terminal lightning impulse withstand voltage of HCSR is 170 kV. The inter-arm lightning impulse withstand voltage of HCSR is 200 kV. The terminal-to-ground lightning impulse withstand voltage of the HCSR-FCL is 1550 kV. |
first_indexed | 2024-04-11T12:57:49Z |
format | Article |
id | doaj.art-f4a30d54978f4cf984070470467a45bb |
institution | Directory Open Access Journal |
issn | 1996-1073 |
language | English |
last_indexed | 2024-04-11T12:57:49Z |
publishDate | 2019-10-01 |
publisher | MDPI AG |
record_format | Article |
series | Energies |
spelling | doaj.art-f4a30d54978f4cf984070470467a45bb2022-12-22T04:23:02ZengMDPI AGEnergies1996-10732019-10-011220384510.3390/en12203845en12203845Research on the Lightning Intruding Overvoltage and Protection Measures of 500 kV AC Fault Current LimiterChangfu Chen0Yongxia Han1Junxiang Liu2Wenxiong Mo3Zhao Yuan4Jianning Huang5Haibo Su6Xiancong Zhang7Kaijian Wu8School of Electric Power, South China University of Technology, Guangzhou 510641, ChinaSchool of Electric Power, South China University of Technology, Guangzhou 510641, ChinaTest & Research Institute of Guangzhou Power Supply Co., Ltd., Guangzhou 514010, ChinaTest & Research Institute of Guangzhou Power Supply Co., Ltd., Guangzhou 514010, ChinaSchool of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, ChinaSchool of Electric Power, South China University of Technology, Guangzhou 510641, ChinaTest & Research Institute of Guangzhou Power Supply Co., Ltd., Guangzhou 514010, ChinaTest & Research Institute of Guangzhou Power Supply Co., Ltd., Guangzhou 514010, ChinaSchool of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, ChinaAs one of the key technologies to solve the problem of high short-circuit current, the fault current limiter (FCL) has become a research hotspot in China and abroad. The overvoltage and protection measures of the FCL are the key technologies for its application. Therefore, this paper studies the lightning intruding overvoltage and protection measures for a 500 kV FCL based on a high coupled split reactor (HCSR). Firstly, according to the main topology of the system and the 500 kV HCSR-FCL structure, the lightning intruding overvoltage simulation model of the 500 kV station, including the nearby transmission lines, is established on the PSCAD (Power Systems Computer Aided Design) program. Secondly, the lightning overvoltage of the equipment in the station and the components of the HCSR-FCL are simulated and analyzed when the transmission lines nearby are subjected to lightning shielding failure and back flashover. Meanwhile, the influence of the HCSR-FCL on the lightning overvoltage of the equipment in the station are compared and analyzed before and after the HCSR-FCL is installed. The simulation results show that the overvoltage of the equipment in the station and the components of the HCSR-FCL is more serious when the shielding failure occurs in the transmission lines nearby. The HCSR-FCL can reduce the lightning overvoltage of the equipment in the station, but the maximum inter-terminal and inter-arm lightning overvoltage of the HCSR can reach 1064 kV and 790 kV, respectively, under the current limiting state and the current sharing state. Finally, methods of increasing the arresters on the transmission lines side of the HCSR-FCL and shunt capacitor between each module of the HCSR-FCL are proposed to reduce the lightning overvoltage. The lightning impulse withstand voltage of each component of the HCSR is also proposed: The inter-terminal lightning impulse withstand voltage of HCSR is 170 kV. The inter-arm lightning impulse withstand voltage of HCSR is 200 kV. The terminal-to-ground lightning impulse withstand voltage of the HCSR-FCL is 1550 kV.https://www.mdpi.com/1996-1073/12/20/3845fault current limiterovervoltagehigh coupled split reactorshunt capacitorlightning impulse withstand voltage |
spellingShingle | Changfu Chen Yongxia Han Junxiang Liu Wenxiong Mo Zhao Yuan Jianning Huang Haibo Su Xiancong Zhang Kaijian Wu Research on the Lightning Intruding Overvoltage and Protection Measures of 500 kV AC Fault Current Limiter Energies fault current limiter overvoltage high coupled split reactor shunt capacitor lightning impulse withstand voltage |
title | Research on the Lightning Intruding Overvoltage and Protection Measures of 500 kV AC Fault Current Limiter |
title_full | Research on the Lightning Intruding Overvoltage and Protection Measures of 500 kV AC Fault Current Limiter |
title_fullStr | Research on the Lightning Intruding Overvoltage and Protection Measures of 500 kV AC Fault Current Limiter |
title_full_unstemmed | Research on the Lightning Intruding Overvoltage and Protection Measures of 500 kV AC Fault Current Limiter |
title_short | Research on the Lightning Intruding Overvoltage and Protection Measures of 500 kV AC Fault Current Limiter |
title_sort | research on the lightning intruding overvoltage and protection measures of 500 kv ac fault current limiter |
topic | fault current limiter overvoltage high coupled split reactor shunt capacitor lightning impulse withstand voltage |
url | https://www.mdpi.com/1996-1073/12/20/3845 |
work_keys_str_mv | AT changfuchen researchonthelightningintrudingovervoltageandprotectionmeasuresof500kvacfaultcurrentlimiter AT yongxiahan researchonthelightningintrudingovervoltageandprotectionmeasuresof500kvacfaultcurrentlimiter AT junxiangliu researchonthelightningintrudingovervoltageandprotectionmeasuresof500kvacfaultcurrentlimiter AT wenxiongmo researchonthelightningintrudingovervoltageandprotectionmeasuresof500kvacfaultcurrentlimiter AT zhaoyuan researchonthelightningintrudingovervoltageandprotectionmeasuresof500kvacfaultcurrentlimiter AT jianninghuang researchonthelightningintrudingovervoltageandprotectionmeasuresof500kvacfaultcurrentlimiter AT haibosu researchonthelightningintrudingovervoltageandprotectionmeasuresof500kvacfaultcurrentlimiter AT xiancongzhang researchonthelightningintrudingovervoltageandprotectionmeasuresof500kvacfaultcurrentlimiter AT kaijianwu researchonthelightningintrudingovervoltageandprotectionmeasuresof500kvacfaultcurrentlimiter |