Oscillator for Biosensors based on Quartz Crystal Microbalance (QCM)
Quartz crystal is generally used in some applications as a microbalance taking advantage of its capacity to change the resonance frequency according to any surface mass change on the resonator. In this way a quartz crystal can be used as a transducer in a piezoelectric inmunosensor system in order...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universidad de Antioquia
2012-11-01
|
Series: | Revista Facultad de Ingeniería Universidad de Antioquia |
Subjects: | |
Online Access: | https://revistas.udea.edu.co/index.php/ingenieria/article/view/13543 |
_version_ | 1797861656602083328 |
---|---|
author | Yeison Javier Montagut Ferizzola José Vicente García Narbon Yolanda Jiménez Jiménez Carmen March Iborra Angel Montoya Baides Róbinson Alberto Torres Villa Antonio Arnau Vives |
author_facet | Yeison Javier Montagut Ferizzola José Vicente García Narbon Yolanda Jiménez Jiménez Carmen March Iborra Angel Montoya Baides Róbinson Alberto Torres Villa Antonio Arnau Vives |
author_sort | Yeison Javier Montagut Ferizzola |
collection | DOAJ |
description |
Quartz crystal is generally used in some applications as a microbalance taking advantage of its capacity to change the resonance frequency according to any surface mass change on the resonator. In this way a quartz crystal can be used as a transducer in a piezoelectric inmunosensor system in order to detect antigen-antibody bonds.
An interface for Quartz Crystal Microbalances, QCM, based on an improved version of an oscillator in balanced differential configuration and its respective validation as a biosensor characterization system is introduced in this paper. The system was successfully tested in a piezoelectric inmunosensor for detecting the pesticide Carbaryl.
|
first_indexed | 2024-04-09T22:06:44Z |
format | Article |
id | doaj.art-f4c3422e49a346b49b81528a47c879ae |
institution | Directory Open Access Journal |
issn | 0120-6230 2422-2844 |
language | English |
last_indexed | 2024-04-09T22:06:44Z |
publishDate | 2012-11-01 |
publisher | Universidad de Antioquia |
record_format | Article |
series | Revista Facultad de Ingeniería Universidad de Antioquia |
spelling | doaj.art-f4c3422e49a346b49b81528a47c879ae2023-03-23T12:37:15ZengUniversidad de AntioquiaRevista Facultad de Ingeniería Universidad de Antioquia0120-62302422-28442012-11-016110.17533/udea.redin.13543Oscillator for Biosensors based on Quartz Crystal Microbalance (QCM)Yeison Javier Montagut Ferizzola0José Vicente García Narbon1Yolanda Jiménez Jiménez2Carmen March Iborra3Angel Montoya Baides4Róbinson Alberto Torres Villa5Antonio Arnau Vives6School of Engineering of AntioquiaTechnical University of ValenciaPolytechnic University of ValenciaPolytechnic University of ValenciaPolytechnic University of ValenciaSchool of Engineering of AntioquiaPolytechnic University of Valencia Quartz crystal is generally used in some applications as a microbalance taking advantage of its capacity to change the resonance frequency according to any surface mass change on the resonator. In this way a quartz crystal can be used as a transducer in a piezoelectric inmunosensor system in order to detect antigen-antibody bonds. An interface for Quartz Crystal Microbalances, QCM, based on an improved version of an oscillator in balanced differential configuration and its respective validation as a biosensor characterization system is introduced in this paper. The system was successfully tested in a piezoelectric inmunosensor for detecting the pesticide Carbaryl. https://revistas.udea.edu.co/index.php/ingenieria/article/view/13543oscillatorbiosensorpiezoelectric inmunosensorCarbaryQuartz Crystal Microbalance (QCM) |
spellingShingle | Yeison Javier Montagut Ferizzola José Vicente García Narbon Yolanda Jiménez Jiménez Carmen March Iborra Angel Montoya Baides Róbinson Alberto Torres Villa Antonio Arnau Vives Oscillator for Biosensors based on Quartz Crystal Microbalance (QCM) Revista Facultad de Ingeniería Universidad de Antioquia oscillator biosensor piezoelectric inmunosensor Carbary Quartz Crystal Microbalance (QCM) |
title | Oscillator for Biosensors based on Quartz Crystal Microbalance (QCM) |
title_full | Oscillator for Biosensors based on Quartz Crystal Microbalance (QCM) |
title_fullStr | Oscillator for Biosensors based on Quartz Crystal Microbalance (QCM) |
title_full_unstemmed | Oscillator for Biosensors based on Quartz Crystal Microbalance (QCM) |
title_short | Oscillator for Biosensors based on Quartz Crystal Microbalance (QCM) |
title_sort | oscillator for biosensors based on quartz crystal microbalance qcm |
topic | oscillator biosensor piezoelectric inmunosensor Carbary Quartz Crystal Microbalance (QCM) |
url | https://revistas.udea.edu.co/index.php/ingenieria/article/view/13543 |
work_keys_str_mv | AT yeisonjaviermontagutferizzola oscillatorforbiosensorsbasedonquartzcrystalmicrobalanceqcm AT josevicentegarcianarbon oscillatorforbiosensorsbasedonquartzcrystalmicrobalanceqcm AT yolandajimenezjimenez oscillatorforbiosensorsbasedonquartzcrystalmicrobalanceqcm AT carmenmarchiborra oscillatorforbiosensorsbasedonquartzcrystalmicrobalanceqcm AT angelmontoyabaides oscillatorforbiosensorsbasedonquartzcrystalmicrobalanceqcm AT robinsonalbertotorresvilla oscillatorforbiosensorsbasedonquartzcrystalmicrobalanceqcm AT antonioarnauvives oscillatorforbiosensorsbasedonquartzcrystalmicrobalanceqcm |