Oscillator for Biosensors based on Quartz Crystal Microbalance (QCM)

Quartz crystal is generally used in some applications as a microbalance taking advantage of its capacity to change the resonance frequency according to any surface mass change on the resonator. In this way a quartz crystal can be used as a transducer in a piezoelectric inmunosensor system in order...

Full description

Bibliographic Details
Main Authors: Yeison Javier Montagut Ferizzola, José Vicente García Narbon, Yolanda Jiménez Jiménez, Carmen March Iborra, Angel Montoya Baides, Róbinson Alberto Torres Villa, Antonio Arnau Vives
Format: Article
Language:English
Published: Universidad de Antioquia 2012-11-01
Series:Revista Facultad de Ingeniería Universidad de Antioquia
Subjects:
Online Access:https://revistas.udea.edu.co/index.php/ingenieria/article/view/13543
_version_ 1797861656602083328
author Yeison Javier Montagut Ferizzola
José Vicente García Narbon
Yolanda Jiménez Jiménez
Carmen March Iborra
Angel Montoya Baides
Róbinson Alberto Torres Villa
Antonio Arnau Vives
author_facet Yeison Javier Montagut Ferizzola
José Vicente García Narbon
Yolanda Jiménez Jiménez
Carmen March Iborra
Angel Montoya Baides
Róbinson Alberto Torres Villa
Antonio Arnau Vives
author_sort Yeison Javier Montagut Ferizzola
collection DOAJ
description Quartz crystal is generally used in some applications as a microbalance taking advantage of its capacity to change the resonance frequency according to any surface mass change on the resonator. In this way a quartz crystal can be used as a transducer in a piezoelectric inmunosensor system in order to detect antigen-antibody bonds. An interface for Quartz Crystal Microbalances, QCM, based on an improved version of an oscillator in balanced differential configuration and its respective validation as a biosensor characterization system is introduced in this paper. The system was successfully tested in a piezoelectric inmunosensor for detecting the pesticide Carbaryl.
first_indexed 2024-04-09T22:06:44Z
format Article
id doaj.art-f4c3422e49a346b49b81528a47c879ae
institution Directory Open Access Journal
issn 0120-6230
2422-2844
language English
last_indexed 2024-04-09T22:06:44Z
publishDate 2012-11-01
publisher Universidad de Antioquia
record_format Article
series Revista Facultad de Ingeniería Universidad de Antioquia
spelling doaj.art-f4c3422e49a346b49b81528a47c879ae2023-03-23T12:37:15ZengUniversidad de AntioquiaRevista Facultad de Ingeniería Universidad de Antioquia0120-62302422-28442012-11-016110.17533/udea.redin.13543Oscillator for Biosensors based on Quartz Crystal Microbalance (QCM)Yeison Javier Montagut Ferizzola0José Vicente García Narbon1Yolanda Jiménez Jiménez2Carmen March Iborra3Angel Montoya Baides4Róbinson Alberto Torres Villa5Antonio Arnau Vives6School of Engineering of AntioquiaTechnical University of ValenciaPolytechnic University of ValenciaPolytechnic University of ValenciaPolytechnic University of ValenciaSchool of Engineering of AntioquiaPolytechnic University of Valencia Quartz crystal is generally used in some applications as a microbalance taking advantage of its capacity to change the resonance frequency according to any surface mass change on the resonator. In this way a quartz crystal can be used as a transducer in a piezoelectric inmunosensor system in order to detect antigen-antibody bonds. An interface for Quartz Crystal Microbalances, QCM, based on an improved version of an oscillator in balanced differential configuration and its respective validation as a biosensor characterization system is introduced in this paper. The system was successfully tested in a piezoelectric inmunosensor for detecting the pesticide Carbaryl. https://revistas.udea.edu.co/index.php/ingenieria/article/view/13543oscillatorbiosensorpiezoelectric inmunosensorCarbaryQuartz Crystal Microbalance (QCM)
spellingShingle Yeison Javier Montagut Ferizzola
José Vicente García Narbon
Yolanda Jiménez Jiménez
Carmen March Iborra
Angel Montoya Baides
Róbinson Alberto Torres Villa
Antonio Arnau Vives
Oscillator for Biosensors based on Quartz Crystal Microbalance (QCM)
Revista Facultad de Ingeniería Universidad de Antioquia
oscillator
biosensor
piezoelectric inmunosensor
Carbary
Quartz Crystal Microbalance (QCM)
title Oscillator for Biosensors based on Quartz Crystal Microbalance (QCM)
title_full Oscillator for Biosensors based on Quartz Crystal Microbalance (QCM)
title_fullStr Oscillator for Biosensors based on Quartz Crystal Microbalance (QCM)
title_full_unstemmed Oscillator for Biosensors based on Quartz Crystal Microbalance (QCM)
title_short Oscillator for Biosensors based on Quartz Crystal Microbalance (QCM)
title_sort oscillator for biosensors based on quartz crystal microbalance qcm
topic oscillator
biosensor
piezoelectric inmunosensor
Carbary
Quartz Crystal Microbalance (QCM)
url https://revistas.udea.edu.co/index.php/ingenieria/article/view/13543
work_keys_str_mv AT yeisonjaviermontagutferizzola oscillatorforbiosensorsbasedonquartzcrystalmicrobalanceqcm
AT josevicentegarcianarbon oscillatorforbiosensorsbasedonquartzcrystalmicrobalanceqcm
AT yolandajimenezjimenez oscillatorforbiosensorsbasedonquartzcrystalmicrobalanceqcm
AT carmenmarchiborra oscillatorforbiosensorsbasedonquartzcrystalmicrobalanceqcm
AT angelmontoyabaides oscillatorforbiosensorsbasedonquartzcrystalmicrobalanceqcm
AT robinsonalbertotorresvilla oscillatorforbiosensorsbasedonquartzcrystalmicrobalanceqcm
AT antonioarnauvives oscillatorforbiosensorsbasedonquartzcrystalmicrobalanceqcm