Thermal protection of low-rise buildings from light steel thin-walled structures

Thermal protection providing of frame buildings in the extreme conditions of the Far North depends on air infiltration. Elements of buildings frame on light steel thin-walled structures (LSTS below) technology – lightweight, thin-walled steel profiles make up multiple thermal bridges. The basic prin...

Full description

Bibliographic Details
Main Authors: Terentii Kornilov, Alexsandr Nikiforov
Format: Article
Language:English
Published: Peter the Great St. Petersburg Polytechnic University 2018-12-01
Series:Инженерно-строительный журнал
Subjects:
Online Access:https://engstroy.spbstu.ru/en/article/2018.84.14/
_version_ 1818353443592470528
author Terentii Kornilov
Alexsandr Nikiforov
author_facet Terentii Kornilov
Alexsandr Nikiforov
author_sort Terentii Kornilov
collection DOAJ
description Thermal protection providing of frame buildings in the extreme conditions of the Far North depends on air infiltration. Elements of buildings frame on light steel thin-walled structures (LSTS below) technology – lightweight, thin-walled steel profiles make up multiple thermal bridges. The basic principles of designing the exterior walling of low-rise buildings from LSTS in the Far North are developed with taking into account the increased air infiltration and the heat transfer components and assemblies. The construction with double insulation layer and the intermediate airtight barrier of particleboard, the indicative panels (OSB below) are proposed as the exterior walls. The concrete ground slab and thermofiller using of lightweight concrete blocks are recommended in buildings with pile foundation. The two-stage disposition of blocks between the steel frame elements and the basement ceiling allow to overlap joints of thermal insulation materials with other structural elements which reduces the impact of air infiltration. The specific heat loss values for a multilayer wall construction and assembly of its coupling with a ground overlap, depending on various parameters are obtained with the calculating program application of threedimensional temperature fields.
first_indexed 2024-12-13T19:09:37Z
format Article
id doaj.art-f4c765ca97744d429be87e6440c749f3
institution Directory Open Access Journal
issn 2071-0305
language English
last_indexed 2024-12-13T19:09:37Z
publishDate 2018-12-01
publisher Peter the Great St. Petersburg Polytechnic University
record_format Article
series Инженерно-строительный журнал
spelling doaj.art-f4c765ca97744d429be87e6440c749f32022-12-21T23:34:27ZengPeter the Great St. Petersburg Polytechnic UniversityИнженерно-строительный журнал2071-03052018-12-0184814014910.18720/MCE.84.14Thermal protection of low-rise buildings from light steel thin-walled structuresTerentii Kornilov0Alexsandr Nikiforov1North-Eastern Federal University named after M.K. AmmosovNorth-Eastern Federal University named after M.K. AmmosovThermal protection providing of frame buildings in the extreme conditions of the Far North depends on air infiltration. Elements of buildings frame on light steel thin-walled structures (LSTS below) technology – lightweight, thin-walled steel profiles make up multiple thermal bridges. The basic principles of designing the exterior walling of low-rise buildings from LSTS in the Far North are developed with taking into account the increased air infiltration and the heat transfer components and assemblies. The construction with double insulation layer and the intermediate airtight barrier of particleboard, the indicative panels (OSB below) are proposed as the exterior walls. The concrete ground slab and thermofiller using of lightweight concrete blocks are recommended in buildings with pile foundation. The two-stage disposition of blocks between the steel frame elements and the basement ceiling allow to overlap joints of thermal insulation materials with other structural elements which reduces the impact of air infiltration. The specific heat loss values for a multilayer wall construction and assembly of its coupling with a ground overlap, depending on various parameters are obtained with the calculating program application of threedimensional temperature fields.https://engstroy.spbstu.ru/en/article/2018.84.14/thermal protectioninfiltrationtemperaturelight steel thin-walled structurescold bridgeswall structuresbasement floor
spellingShingle Terentii Kornilov
Alexsandr Nikiforov
Thermal protection of low-rise buildings from light steel thin-walled structures
Инженерно-строительный журнал
thermal protection
infiltration
temperature
light steel thin-walled structures
cold bridges
wall structures
basement floor
title Thermal protection of low-rise buildings from light steel thin-walled structures
title_full Thermal protection of low-rise buildings from light steel thin-walled structures
title_fullStr Thermal protection of low-rise buildings from light steel thin-walled structures
title_full_unstemmed Thermal protection of low-rise buildings from light steel thin-walled structures
title_short Thermal protection of low-rise buildings from light steel thin-walled structures
title_sort thermal protection of low rise buildings from light steel thin walled structures
topic thermal protection
infiltration
temperature
light steel thin-walled structures
cold bridges
wall structures
basement floor
url https://engstroy.spbstu.ru/en/article/2018.84.14/
work_keys_str_mv AT terentiikornilov thermalprotectionoflowrisebuildingsfromlightsteelthinwalledstructures
AT alexsandrnikiforov thermalprotectionoflowrisebuildingsfromlightsteelthinwalledstructures