Frequency and Acceleration Measurement for the Above Knee Prosthetic Limb and its Comparison with the Healthy Limb

omfort, stability, weightiness, stiffness, flexibility, toughness and cost are the most important goals during which all researchers try to reach. In this work, the first challenge is to design and manufacture vibration measurement system which consists of a shaker ,cam, motors, speed varitor and a...

Full description

Bibliographic Details
Main Authors: Jumaa S. Chiad, Bashar A. Bedaiwi
Format: Article
Language:Arabic
Published: Mustansiriyah University/College of Engineering 2012-12-01
Series:Journal of Engineering and Sustainable Development
Subjects:
Online Access:https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/1255
_version_ 1798022546720817152
author Jumaa S. Chiad
Bashar A. Bedaiwi
author_facet Jumaa S. Chiad
Bashar A. Bedaiwi
author_sort Jumaa S. Chiad
collection DOAJ
description omfort, stability, weightiness, stiffness, flexibility, toughness and cost are the most important goals during which all researchers try to reach. In this work, the first challenge is to design and manufacture vibration measurement system which consists of a shaker ,cam, motors, speed varitor and accelerometer. This system is used to measure displacement ,velocity ,acceleration and frequency in amputation joint in the whole body in the selected eleven points with four speed motor (500,600,700 and 800 rpm).The amputee case study is of age, weight, length and the residual amputee limb of 28 years, 75kg, 175cm and 38 cm respectively. The amputee lost his lower limb due to a car accident since 2002.Results show that the value of acceleration and frequency increases when motor speed increases. While the acceleration and frequency decreases when accelerometer position from the shaking table increases . Moreover , the acceleration values for prosthetic limb will be more than of the healthy limb with percent of about (10.3,8.1,8.4,11.6,2.7,6.8)% for foot, ankle, leg, knee, thigh and hip respectively. While the acceleration values of artificial limb with liner are less than those of artificial limb without liner with (7.8,0.86,23.05,1.01,2.6 and 5.04)% for foot, ankle, leg, knee, thigh and hip, respectively .
first_indexed 2024-04-11T17:31:48Z
format Article
id doaj.art-f4cdeac3dbba4c91a43ffe9c67bbf8de
institution Directory Open Access Journal
issn 2520-0917
2520-0925
language Arabic
last_indexed 2024-04-11T17:31:48Z
publishDate 2012-12-01
publisher Mustansiriyah University/College of Engineering
record_format Article
series Journal of Engineering and Sustainable Development
spelling doaj.art-f4cdeac3dbba4c91a43ffe9c67bbf8de2022-12-22T04:12:00ZaraMustansiriyah University/College of EngineeringJournal of Engineering and Sustainable Development2520-09172520-09252012-12-01164Frequency and Acceleration Measurement for the Above Knee Prosthetic Limb and its Comparison with the Healthy LimbJumaa S. Chiad0Bashar A. Bedaiwi1Mechanical Engineering Department, Al-Mustansiriyah University, Baghdad, IraqMechanical Engineering Department, Al-Mustansiriyah University, Baghdad, Iraq omfort, stability, weightiness, stiffness, flexibility, toughness and cost are the most important goals during which all researchers try to reach. In this work, the first challenge is to design and manufacture vibration measurement system which consists of a shaker ,cam, motors, speed varitor and accelerometer. This system is used to measure displacement ,velocity ,acceleration and frequency in amputation joint in the whole body in the selected eleven points with four speed motor (500,600,700 and 800 rpm).The amputee case study is of age, weight, length and the residual amputee limb of 28 years, 75kg, 175cm and 38 cm respectively. The amputee lost his lower limb due to a car accident since 2002.Results show that the value of acceleration and frequency increases when motor speed increases. While the acceleration and frequency decreases when accelerometer position from the shaking table increases . Moreover , the acceleration values for prosthetic limb will be more than of the healthy limb with percent of about (10.3,8.1,8.4,11.6,2.7,6.8)% for foot, ankle, leg, knee, thigh and hip respectively. While the acceleration values of artificial limb with liner are less than those of artificial limb without liner with (7.8,0.86,23.05,1.01,2.6 and 5.04)% for foot, ankle, leg, knee, thigh and hip, respectively . https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/1255Prostheticamputationartificial limbabove knee accelerometer
spellingShingle Jumaa S. Chiad
Bashar A. Bedaiwi
Frequency and Acceleration Measurement for the Above Knee Prosthetic Limb and its Comparison with the Healthy Limb
Journal of Engineering and Sustainable Development
Prosthetic
amputation
artificial limb
above knee accelerometer
title Frequency and Acceleration Measurement for the Above Knee Prosthetic Limb and its Comparison with the Healthy Limb
title_full Frequency and Acceleration Measurement for the Above Knee Prosthetic Limb and its Comparison with the Healthy Limb
title_fullStr Frequency and Acceleration Measurement for the Above Knee Prosthetic Limb and its Comparison with the Healthy Limb
title_full_unstemmed Frequency and Acceleration Measurement for the Above Knee Prosthetic Limb and its Comparison with the Healthy Limb
title_short Frequency and Acceleration Measurement for the Above Knee Prosthetic Limb and its Comparison with the Healthy Limb
title_sort frequency and acceleration measurement for the above knee prosthetic limb and its comparison with the healthy limb
topic Prosthetic
amputation
artificial limb
above knee accelerometer
url https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/1255
work_keys_str_mv AT jumaaschiad frequencyandaccelerationmeasurementfortheabovekneeprostheticlimbanditscomparisonwiththehealthylimb
AT basharabedaiwi frequencyandaccelerationmeasurementfortheabovekneeprostheticlimbanditscomparisonwiththehealthylimb