Post-Fire Seismic Performance of Concrete-Filled Steel Tube Frame Structures Considering Soil-Structure Interaction (SSI)
Currently, reinforced thin-walled irregular steel tube concrete frame structures have been applied in engineering, but there are few researches on the seismic performance of this type of structures after fire. The seismic performance of structures after fire is generally carried out based on rigid f...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2024-02-01
|
Series: | Buildings |
Subjects: | |
Online Access: | https://www.mdpi.com/2075-5309/14/2/555 |
_version_ | 1797298728792489984 |
---|---|
author | Weiwei Wang Xuetao Lyu Jun Zheng Shanchang Yi Jiehong Li Yang Yu |
author_facet | Weiwei Wang Xuetao Lyu Jun Zheng Shanchang Yi Jiehong Li Yang Yu |
author_sort | Weiwei Wang |
collection | DOAJ |
description | Currently, reinforced thin-walled irregular steel tube concrete frame structures have been applied in engineering, but there are few researches on the seismic performance of this type of structures after fire. The seismic performance of structures after fire is generally carried out based on rigid foundation conditions. Therefore, it is of certain engineering and theoretical value to study the seismic performance considering the SSI (soil–structure interaction) in this paper. ABAQUS is employed to establish the finite element models of the reinforced thin-walled irregular steel tube concrete frame structure considering the SSI after a fire. The paper analyzes the impact of different site conditions and fire durations on the structural natural vibration period, maximum acceleration, inter-story shear force, and maximum inter-story displacement angle. The results show that the consideration of the SSI increases the basic natural vibration period of the structure by 10–30%. The softer the soil and the longer the fire duration, the more significant the increase. For harder soil, lower seismic intensity, and shorter fire duration, the acceleration assigned to the structure and foundation after considering the SSI is smaller than the results assuming a rigid foundation. The change in inter-story shear force is mainly determined by the acceleration of the structure and foundation. The inter-story displacement angle increases when considering the SSI, and the increase is more significant with softer soil, larger seismic wave acceleration amplitude, and longer fire duration. |
first_indexed | 2024-03-07T22:39:13Z |
format | Article |
id | doaj.art-f54f5563a3084ee0af8c246782346b77 |
institution | Directory Open Access Journal |
issn | 2075-5309 |
language | English |
last_indexed | 2024-03-07T22:39:13Z |
publishDate | 2024-02-01 |
publisher | MDPI AG |
record_format | Article |
series | Buildings |
spelling | doaj.art-f54f5563a3084ee0af8c246782346b772024-02-23T15:10:34ZengMDPI AGBuildings2075-53092024-02-0114255510.3390/buildings14020555Post-Fire Seismic Performance of Concrete-Filled Steel Tube Frame Structures Considering Soil-Structure Interaction (SSI)Weiwei Wang0Xuetao Lyu1Jun Zheng2Shanchang Yi3Jiehong Li4Yang Yu5School of Architectural Engineering, Guangzhou Vocational and Technical University of Science and Technology, Guangzhou 510000, ChinaSchool of Transportation and Civil Engineering, Foshan University of Science and Technology, Foshan 528231, ChinaSchool of Architectural Engineering, Guangzhou Vocational and Technical University of Science and Technology, Guangzhou 510000, ChinaSchool of Civil Engineering, Changsha University of Science & Technology, Changsha 410114, ChinaCentre for Infrastructure Engineering and Safety, School of Civil and Environmental Engineering, The University of New South Wales, Kensington, NSW 2052, AustraliaCentre for Infrastructure Engineering and Safety, School of Civil and Environmental Engineering, The University of New South Wales, Kensington, NSW 2052, AustraliaCurrently, reinforced thin-walled irregular steel tube concrete frame structures have been applied in engineering, but there are few researches on the seismic performance of this type of structures after fire. The seismic performance of structures after fire is generally carried out based on rigid foundation conditions. Therefore, it is of certain engineering and theoretical value to study the seismic performance considering the SSI (soil–structure interaction) in this paper. ABAQUS is employed to establish the finite element models of the reinforced thin-walled irregular steel tube concrete frame structure considering the SSI after a fire. The paper analyzes the impact of different site conditions and fire durations on the structural natural vibration period, maximum acceleration, inter-story shear force, and maximum inter-story displacement angle. The results show that the consideration of the SSI increases the basic natural vibration period of the structure by 10–30%. The softer the soil and the longer the fire duration, the more significant the increase. For harder soil, lower seismic intensity, and shorter fire duration, the acceleration assigned to the structure and foundation after considering the SSI is smaller than the results assuming a rigid foundation. The change in inter-story shear force is mainly determined by the acceleration of the structure and foundation. The inter-story displacement angle increases when considering the SSI, and the increase is more significant with softer soil, larger seismic wave acceleration amplitude, and longer fire duration.https://www.mdpi.com/2075-5309/14/2/555post fireSSI effectthin-walled special-shaped steel tube concreteframeworkseismic performance |
spellingShingle | Weiwei Wang Xuetao Lyu Jun Zheng Shanchang Yi Jiehong Li Yang Yu Post-Fire Seismic Performance of Concrete-Filled Steel Tube Frame Structures Considering Soil-Structure Interaction (SSI) Buildings post fire SSI effect thin-walled special-shaped steel tube concrete framework seismic performance |
title | Post-Fire Seismic Performance of Concrete-Filled Steel Tube Frame Structures Considering Soil-Structure Interaction (SSI) |
title_full | Post-Fire Seismic Performance of Concrete-Filled Steel Tube Frame Structures Considering Soil-Structure Interaction (SSI) |
title_fullStr | Post-Fire Seismic Performance of Concrete-Filled Steel Tube Frame Structures Considering Soil-Structure Interaction (SSI) |
title_full_unstemmed | Post-Fire Seismic Performance of Concrete-Filled Steel Tube Frame Structures Considering Soil-Structure Interaction (SSI) |
title_short | Post-Fire Seismic Performance of Concrete-Filled Steel Tube Frame Structures Considering Soil-Structure Interaction (SSI) |
title_sort | post fire seismic performance of concrete filled steel tube frame structures considering soil structure interaction ssi |
topic | post fire SSI effect thin-walled special-shaped steel tube concrete framework seismic performance |
url | https://www.mdpi.com/2075-5309/14/2/555 |
work_keys_str_mv | AT weiweiwang postfireseismicperformanceofconcretefilledsteeltubeframestructuresconsideringsoilstructureinteractionssi AT xuetaolyu postfireseismicperformanceofconcretefilledsteeltubeframestructuresconsideringsoilstructureinteractionssi AT junzheng postfireseismicperformanceofconcretefilledsteeltubeframestructuresconsideringsoilstructureinteractionssi AT shanchangyi postfireseismicperformanceofconcretefilledsteeltubeframestructuresconsideringsoilstructureinteractionssi AT jiehongli postfireseismicperformanceofconcretefilledsteeltubeframestructuresconsideringsoilstructureinteractionssi AT yangyu postfireseismicperformanceofconcretefilledsteeltubeframestructuresconsideringsoilstructureinteractionssi |