Experience of commissioning of the V-392M reactor plant passive heat removal system
The paper considers structural features of components in a passive heat removal system (PHRS) used for the first time in Russia in the VVER-1200 reactor. It describes the design deficiencies of the system's air gate valves and regulators detected in the process of pre-commissioning activities a...