Prediction of failure load of RC and R-ECC dapped-end beams

The dapped-end reinforcements of a control beam have been designed conforming to requirement of the PCI code. The dapped-end reinforcements of other beams were derived from the control beam that involve the scheme variation of the hanger or diagonal reinforcements. Some selected beams utilize the en...

Full description

Bibliographic Details
Main Authors: Bashar S. Mohammed, Muhammad Aswin, M.S. Liew
Format: Article
Language:English
Published: Elsevier 2020-12-01
Series:Case Studies in Construction Materials
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2214509520301054
_version_ 1829470144178421760
author Bashar S. Mohammed
Muhammad Aswin
M.S. Liew
author_facet Bashar S. Mohammed
Muhammad Aswin
M.S. Liew
author_sort Bashar S. Mohammed
collection DOAJ
description The dapped-end reinforcements of a control beam have been designed conforming to requirement of the PCI code. The dapped-end reinforcements of other beams were derived from the control beam that involve the scheme variation of the hanger or diagonal reinforcements. Some selected beams utilize the engineered cementitious composites (ECC) in the dapped-end region. Twenty-seven large-scaled beams with dapped-end have been prepared, cast and tested. All beams were tested under the three-point loading up to failure. To localize effect of the shear failure, the shear span-depth ratio (av/d) of 1.43 has been carried out. Dapped-end beam (DEB) specified in PCI code has nominal shear span-depth ratio (an/d) less than 1, but in this study, several beams use an/d larger than 1. For analytical purpose, the design equations specified in PCI code have been used for the analysis requirement. By comparing against the test results, the analysis results that using the design equations of PCI code provide a significant difference, in which the mean value of analysis-test results ratio is 0.71. The design equations specified in PCI code were reliable to design the dapped-end reinforcements, but these equations have not yet able to accommodate adequately, in analyzing and predicting the failure load of DEBs that have the dapped-end reinforcements scheme varied.
first_indexed 2024-12-14T01:41:26Z
format Article
id doaj.art-f6af7c13eab047dd9299dd67c479f57d
institution Directory Open Access Journal
issn 2214-5095
language English
last_indexed 2024-12-14T01:41:26Z
publishDate 2020-12-01
publisher Elsevier
record_format Article
series Case Studies in Construction Materials
spelling doaj.art-f6af7c13eab047dd9299dd67c479f57d2022-12-21T23:21:44ZengElsevierCase Studies in Construction Materials2214-50952020-12-0113e00433Prediction of failure load of RC and R-ECC dapped-end beamsBashar S. Mohammed0Muhammad Aswin1M.S. Liew2Department of Civil and Environmental Engineering, Universiti Teknologi PETRONAS, 32610 Bandar Seri Iskandar, Perak Darul Ridzuan, Malaysia; Corresponding author.Departemen Teknik Sipil, Universitas Sumatera Utara, Medan 20155, IndonesiaDepartment of Civil and Environmental Engineering, Universiti Teknologi PETRONAS, 32610 Bandar Seri Iskandar, Perak Darul Ridzuan, MalaysiaThe dapped-end reinforcements of a control beam have been designed conforming to requirement of the PCI code. The dapped-end reinforcements of other beams were derived from the control beam that involve the scheme variation of the hanger or diagonal reinforcements. Some selected beams utilize the engineered cementitious composites (ECC) in the dapped-end region. Twenty-seven large-scaled beams with dapped-end have been prepared, cast and tested. All beams were tested under the three-point loading up to failure. To localize effect of the shear failure, the shear span-depth ratio (av/d) of 1.43 has been carried out. Dapped-end beam (DEB) specified in PCI code has nominal shear span-depth ratio (an/d) less than 1, but in this study, several beams use an/d larger than 1. For analytical purpose, the design equations specified in PCI code have been used for the analysis requirement. By comparing against the test results, the analysis results that using the design equations of PCI code provide a significant difference, in which the mean value of analysis-test results ratio is 0.71. The design equations specified in PCI code were reliable to design the dapped-end reinforcements, but these equations have not yet able to accommodate adequately, in analyzing and predicting the failure load of DEBs that have the dapped-end reinforcements scheme varied.http://www.sciencedirect.com/science/article/pii/S2214509520301054Dapped-end beamsHanger reinforcementsDiagonal reinforcementsEngineered cementitious composites (ECC)PCI provisionsThe predicted failure load
spellingShingle Bashar S. Mohammed
Muhammad Aswin
M.S. Liew
Prediction of failure load of RC and R-ECC dapped-end beams
Case Studies in Construction Materials
Dapped-end beams
Hanger reinforcements
Diagonal reinforcements
Engineered cementitious composites (ECC)
PCI provisions
The predicted failure load
title Prediction of failure load of RC and R-ECC dapped-end beams
title_full Prediction of failure load of RC and R-ECC dapped-end beams
title_fullStr Prediction of failure load of RC and R-ECC dapped-end beams
title_full_unstemmed Prediction of failure load of RC and R-ECC dapped-end beams
title_short Prediction of failure load of RC and R-ECC dapped-end beams
title_sort prediction of failure load of rc and r ecc dapped end beams
topic Dapped-end beams
Hanger reinforcements
Diagonal reinforcements
Engineered cementitious composites (ECC)
PCI provisions
The predicted failure load
url http://www.sciencedirect.com/science/article/pii/S2214509520301054
work_keys_str_mv AT basharsmohammed predictionoffailureloadofrcandreccdappedendbeams
AT muhammadaswin predictionoffailureloadofrcandreccdappedendbeams
AT msliew predictionoffailureloadofrcandreccdappedendbeams