Particularities of metrological control of non-contact systems for measuring the geometric dimensions of metal products.

OJSC “BSW–Management Company of the Holding “BMC”, non-contact systems for measuring the outer diameters of products are widely used for measuring geometric dimensions. Diameter measurement systems are used to obtain reliable, true and accurate measurements. The method that provides continuous and n...

Full description

Bibliographic Details
Main Authors: O. V. Daineko, L. F. Kalinovskaya, N. V. Bessonov
Format: Article
Language:English
Published: Belarusian National Technical University 2021-03-01
Series:Litʹë i Metallurgiâ
Subjects:
Online Access:https://lim.bntu.by/jour/article/view/3303
_version_ 1811182834706022400
author O. V. Daineko
L. F. Kalinovskaya
N. V. Bessonov
author_facet O. V. Daineko
L. F. Kalinovskaya
N. V. Bessonov
author_sort O. V. Daineko
collection DOAJ
description OJSC “BSW–Management Company of the Holding “BMC”, non-contact systems for measuring the outer diameters of products are widely used for measuring geometric dimensions. Diameter measurement systems are used to obtain reliable, true and accurate measurements. The method that provides continuous and non – contact control of these systems is the light -and – dark method of measuring the diameter.To ensure the reliability of the measurement results, the diameter measurement systems must undergo metrological control – calibration. Calibration is carried out according to the developed methodology, which specifies the order of work, requirements for standards, processing of measurement and evaluation results, and registration of calibration results. To assess the extended uncertainty, a mathematical model is created that takes into account all the corrections that affect the result of the assessment, each of which is subjected to a thorough analysis.Calibration of diameter measurement systems allows to evaluate their real deviations in operating conditions, which allows to ensure the accuracy and reliability of measuring the geometric dimensions of metal products at all stages of its production.
first_indexed 2024-04-11T09:38:19Z
format Article
id doaj.art-f7a472b22e0544198e9b4ba5358f9213
institution Directory Open Access Journal
issn 1683-6065
2414-0406
language English
last_indexed 2024-04-11T09:38:19Z
publishDate 2021-03-01
publisher Belarusian National Technical University
record_format Article
series Litʹë i Metallurgiâ
spelling doaj.art-f7a472b22e0544198e9b4ba5358f92132022-12-22T04:31:32ZengBelarusian National Technical UniversityLitʹë i Metallurgiâ1683-60652414-04062021-03-0101919410.21122/1683-6065-2021-1-91-943194Particularities of metrological control of non-contact systems for measuring the geometric dimensions of metal products.O. V. Daineko0L. F. Kalinovskaya1N. V. Bessonov2BSW–Management Company of the Holding “BMC”BSW–Management Company of the Holding “BMC”BSW–Management Company of the Holding “BMC”OJSC “BSW–Management Company of the Holding “BMC”, non-contact systems for measuring the outer diameters of products are widely used for measuring geometric dimensions. Diameter measurement systems are used to obtain reliable, true and accurate measurements. The method that provides continuous and non – contact control of these systems is the light -and – dark method of measuring the diameter.To ensure the reliability of the measurement results, the diameter measurement systems must undergo metrological control – calibration. Calibration is carried out according to the developed methodology, which specifies the order of work, requirements for standards, processing of measurement and evaluation results, and registration of calibration results. To assess the extended uncertainty, a mathematical model is created that takes into account all the corrections that affect the result of the assessment, each of which is subjected to a thorough analysis.Calibration of diameter measurement systems allows to evaluate their real deviations in operating conditions, which allows to ensure the accuracy and reliability of measuring the geometric dimensions of metal products at all stages of its production.https://lim.bntu.by/jour/article/view/3303diameter measurement systemsextended uncertaintycalibrationmathematical model
spellingShingle O. V. Daineko
L. F. Kalinovskaya
N. V. Bessonov
Particularities of metrological control of non-contact systems for measuring the geometric dimensions of metal products.
Litʹë i Metallurgiâ
diameter measurement systems
extended uncertainty
calibration
mathematical model
title Particularities of metrological control of non-contact systems for measuring the geometric dimensions of metal products.
title_full Particularities of metrological control of non-contact systems for measuring the geometric dimensions of metal products.
title_fullStr Particularities of metrological control of non-contact systems for measuring the geometric dimensions of metal products.
title_full_unstemmed Particularities of metrological control of non-contact systems for measuring the geometric dimensions of metal products.
title_short Particularities of metrological control of non-contact systems for measuring the geometric dimensions of metal products.
title_sort particularities of metrological control of non contact systems for measuring the geometric dimensions of metal products
topic diameter measurement systems
extended uncertainty
calibration
mathematical model
url https://lim.bntu.by/jour/article/view/3303
work_keys_str_mv AT ovdaineko particularitiesofmetrologicalcontrolofnoncontactsystemsformeasuringthegeometricdimensionsofmetalproducts
AT lfkalinovskaya particularitiesofmetrologicalcontrolofnoncontactsystemsformeasuringthegeometricdimensionsofmetalproducts
AT nvbessonov particularitiesofmetrologicalcontrolofnoncontactsystemsformeasuringthegeometricdimensionsofmetalproducts