ES-PROTECTED ELECTRIC CONNECTOR

Background. The article presents the results of development of the electric connector providing protection of the electric circuits against the static electricity and the induced currents. Application of mining charges with embedded electric blasting caps and electric spark igniters implies precau...

Full description

Bibliographic Details
Main Authors: V.N. Kitaev, M.A. Dremkov, А.А. Uralev
Format: Article
Language:English
Published: Penza State University Publishing House 2023-03-01
Series:Надежность и качество сложных систем
Subjects:
_version_ 1797823672740741120
author V.N. Kitaev
M.A. Dremkov
А.А. Uralev
author_facet V.N. Kitaev
M.A. Dremkov
А.А. Uralev
author_sort V.N. Kitaev
collection DOAJ
description Background. The article presents the results of development of the electric connector providing protection of the electric circuits against the static electricity and the induced currents. Application of mining charges with embedded electric blasting caps and electric spark igniters implies precautions against the static electricity and the induced currents such as a worker grounding, release of the worker from the static electricity by touching the earthed conducting element before starting the work, which are not consistently performed because of notorious human factor. Probable mishandling, especially at a moment of joining the connector, may initiate the pyrotechnic element, resulting in the tragic consequences. To eliminate the human factor in such application the engineering problem is solved on shunting the electric circuit to body in detached state and de-shunting it when joining. Available connectors of similar function are very large and they are restricted in application because of bounded number of electrical circuits with earthed contacts they form in detached state. Expected engineering result of developed electric conductor is to make safe the use of the electric connectors in small-scale engineering systems of tight integration, critical to both the static electricity and the induced currents. Materials and methods. Developed electric connector guaranties the reliable auto-shunting of all electrical circuits coming through the electric connector to body in unconnected state barring from occurrence of static electricity and currents induced by external magnetic fields. The circuits stay shunted when unconnected to keep safety. At joining the connector the electrical circuit shunting is tripped automatically, assuring the reliable connection. Automatic on/off shunting eliminates possible human mistakes when joining/detaching the connector for safety of the whole item. The plug of developed connector mates with commercially available sockets that widen its application area. Results and conclusions. The connector assures reliable functioning of the in small-scale engineering systems of tight integration, critical to both the static electricity and the induced currents, which may include, for example, pyrotechnic initiation elements – electrical blasting caps and electric spark igniters. Patent for invention is taken out for the connector.
first_indexed 2024-03-13T10:26:23Z
format Article
id doaj.art-f848cbb9b74243239d5a0095cc1c4934
institution Directory Open Access Journal
issn 2307-4205
language English
last_indexed 2024-03-13T10:26:23Z
publishDate 2023-03-01
publisher Penza State University Publishing House
record_format Article
series Надежность и качество сложных систем
spelling doaj.art-f848cbb9b74243239d5a0095cc1c49342023-05-19T07:51:55ZengPenza State University Publishing HouseНадежность и качество сложных систем2307-42052023-03-01110.21685/2307-4205-2023-1-7ES-PROTECTED ELECTRIC CONNECTORV.N. Kitaev0M.A. Dremkov1А.А. Uralev2Russian Federal Nuclear Center – Zababakhin All-Russian Research Institute of Technical PhysicsRussian Federal Nuclear Center – Zababakhin All-Russian Research Institute of Technical PhysicsRussian Federal Nuclear Center – Zababakhin All-Russian Research Institute of Technical PhysicsBackground. The article presents the results of development of the electric connector providing protection of the electric circuits against the static electricity and the induced currents. Application of mining charges with embedded electric blasting caps and electric spark igniters implies precautions against the static electricity and the induced currents such as a worker grounding, release of the worker from the static electricity by touching the earthed conducting element before starting the work, which are not consistently performed because of notorious human factor. Probable mishandling, especially at a moment of joining the connector, may initiate the pyrotechnic element, resulting in the tragic consequences. To eliminate the human factor in such application the engineering problem is solved on shunting the electric circuit to body in detached state and de-shunting it when joining. Available connectors of similar function are very large and they are restricted in application because of bounded number of electrical circuits with earthed contacts they form in detached state. Expected engineering result of developed electric conductor is to make safe the use of the electric connectors in small-scale engineering systems of tight integration, critical to both the static electricity and the induced currents. Materials and methods. Developed electric connector guaranties the reliable auto-shunting of all electrical circuits coming through the electric connector to body in unconnected state barring from occurrence of static electricity and currents induced by external magnetic fields. The circuits stay shunted when unconnected to keep safety. At joining the connector the electrical circuit shunting is tripped automatically, assuring the reliable connection. Automatic on/off shunting eliminates possible human mistakes when joining/detaching the connector for safety of the whole item. The plug of developed connector mates with commercially available sockets that widen its application area. Results and conclusions. The connector assures reliable functioning of the in small-scale engineering systems of tight integration, critical to both the static electricity and the induced currents, which may include, for example, pyrotechnic initiation elements – electrical blasting caps and electric spark igniters. Patent for invention is taken out for the connector.electric connectorsafetyauto-shunting of electric circuitscontactsreliability
spellingShingle V.N. Kitaev
M.A. Dremkov
А.А. Uralev
ES-PROTECTED ELECTRIC CONNECTOR
Надежность и качество сложных систем
electric connector
safety
auto-shunting of electric circuits
contacts
reliability
title ES-PROTECTED ELECTRIC CONNECTOR
title_full ES-PROTECTED ELECTRIC CONNECTOR
title_fullStr ES-PROTECTED ELECTRIC CONNECTOR
title_full_unstemmed ES-PROTECTED ELECTRIC CONNECTOR
title_short ES-PROTECTED ELECTRIC CONNECTOR
title_sort es protected electric connector
topic electric connector
safety
auto-shunting of electric circuits
contacts
reliability
work_keys_str_mv AT vnkitaev esprotectedelectricconnector
AT madremkov esprotectedelectricconnector
AT aauralev esprotectedelectricconnector