Difficult intubation in a parturient with syringomyelia and Arnold-Chiari malformation: Use of Airtraq™ laryngoscope

Anesthetic technique in parturient with syringomyelia and Arnold-Chiari malformation is variable depending on the teams. Difficult intubation is one of the risks when general anesthesia is opted. Different devices have been used to manage the difficult intubation in pregnant women. We report the use...

Full description

Bibliographic Details
Main Authors: Bensghir Mustapha, K Chkoura, M Elhassani, R Ahtil, H Azendour, N Drissi Kamili
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2011-01-01
Series:Saudi Journal of Anaesthesia
Subjects:
Online Access:http://www.saudija.org/article.asp?issn=1658-354X;year=2011;volume=5;issue=4;spage=419;epage=422;aulast=Mustapha
Description
Summary:Anesthetic technique in parturient with syringomyelia and Arnold-Chiari malformation is variable depending on the teams. Difficult intubation is one of the risks when general anesthesia is opted. Different devices have been used to manage the difficult intubation in pregnant women. We report the use of Airtraq™ laryngoscope after failed standard laryngoscopy in a parturient with syringomyelia and Arnold-Chiari type I malformation.