Simulation of frequency controlled electric drive using scalar control method / Skaliariniu būdu valdomos dažninės elektros pavaros imitacinis tyrimas
This paper presents scalar controlled induction motor model and analysis of dynamic characteristics. The paper considers the closed loop electric drive system with proportional-integral-derivative (PID) regulator. The model of AC drive is presented in synchronous reference frame. Simulation of the p...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Vilnius Gediminas Technical University
2013-05-01
|
Series: | Mokslas: Lietuvos Ateitis |
Subjects: | |
Online Access: | http://journals.vgtu.lt/index.php/MLA/article/view/3811 |
_version_ | 1818875124479164416 |
---|---|
author | Jonas Kriaučiūnas Laurynas Kerpė |
author_facet | Jonas Kriaučiūnas Laurynas Kerpė |
author_sort | Jonas Kriaučiūnas |
collection | DOAJ |
description | This paper presents scalar controlled induction motor model and analysis of dynamic characteristics. The paper considers the closed loop electric drive system with proportional-integral-derivative (PID) regulator. The model of AC drive is presented in synchronous reference frame. Simulation of the proposed system is considered with different speed reference and load signals, also with different PID regulator parameters (coefficients KP, KI, KD). The selected and tuned regulator significantly decreased speed transient time, and after loading restored it to the reference signal.
Santrauka
Nagrinėjamas dažninės elektros pavaros, valdomos skaliariniu būdu, imitacinių modelių sudarymas ir dinaminių charakteristikų analizė. Sudarytas uždarosios elektros pavaros su proporciniu-integraliniu-diferencialiniu reguliatoriumi (PID) Simulink modelis. Variklio modelis sudarytas sinchroniniu greičiu besisukančioje koordinačių sistemoje. Išnagrinėti dažninės elektros pavaros pereinamieji vyksmai, esant skirtingiems greičio nuostatams, skirtingoms statinėms apkrovoms ir skirtingiems reguliatoriaus suderinimo koeficientams KP , KI , KD. Parinktas ir sukonfigūruotas reguliatorius labai sumažina variklio paleidimo trukmę bei, įjungus apkrovą, atkuria greitį į pradinę, iš anksto nustatytą vertę, lygią nuostatui.
Reikšminiai žodžiai: dažninė pavara, skaliarinis valdymas, imitacinis tyrimas. |
first_indexed | 2024-12-19T13:21:30Z |
format | Article |
id | doaj.art-f8914f14ce9a466182dc8fda191ccd7e |
institution | Directory Open Access Journal |
issn | 2029-2341 2029-2252 |
language | English |
last_indexed | 2024-12-19T13:21:30Z |
publishDate | 2013-05-01 |
publisher | Vilnius Gediminas Technical University |
record_format | Article |
series | Mokslas: Lietuvos Ateitis |
spelling | doaj.art-f8914f14ce9a466182dc8fda191ccd7e2022-12-21T20:19:41ZengVilnius Gediminas Technical UniversityMokslas: Lietuvos Ateitis2029-23412029-22522013-05-015210.3846/mla.2013.20489Simulation of frequency controlled electric drive using scalar control method / Skaliariniu būdu valdomos dažninės elektros pavaros imitacinis tyrimasJonas Kriaučiūnas0Laurynas Kerpė1Vilniaus Gedimino technikos universitetasVilniaus Gedimino technikos universitetasThis paper presents scalar controlled induction motor model and analysis of dynamic characteristics. The paper considers the closed loop electric drive system with proportional-integral-derivative (PID) regulator. The model of AC drive is presented in synchronous reference frame. Simulation of the proposed system is considered with different speed reference and load signals, also with different PID regulator parameters (coefficients KP, KI, KD). The selected and tuned regulator significantly decreased speed transient time, and after loading restored it to the reference signal. Santrauka Nagrinėjamas dažninės elektros pavaros, valdomos skaliariniu būdu, imitacinių modelių sudarymas ir dinaminių charakteristikų analizė. Sudarytas uždarosios elektros pavaros su proporciniu-integraliniu-diferencialiniu reguliatoriumi (PID) Simulink modelis. Variklio modelis sudarytas sinchroniniu greičiu besisukančioje koordinačių sistemoje. Išnagrinėti dažninės elektros pavaros pereinamieji vyksmai, esant skirtingiems greičio nuostatams, skirtingoms statinėms apkrovoms ir skirtingiems reguliatoriaus suderinimo koeficientams KP , KI , KD. Parinktas ir sukonfigūruotas reguliatorius labai sumažina variklio paleidimo trukmę bei, įjungus apkrovą, atkuria greitį į pradinę, iš anksto nustatytą vertę, lygią nuostatui. Reikšminiai žodžiai: dažninė pavara, skaliarinis valdymas, imitacinis tyrimas.http://journals.vgtu.lt/index.php/MLA/article/view/3811frequency controlled drivescalar controlsimulation model |
spellingShingle | Jonas Kriaučiūnas Laurynas Kerpė Simulation of frequency controlled electric drive using scalar control method / Skaliariniu būdu valdomos dažninės elektros pavaros imitacinis tyrimas Mokslas: Lietuvos Ateitis frequency controlled drive scalar control simulation model |
title | Simulation of frequency controlled electric drive using scalar control method / Skaliariniu būdu valdomos dažninės elektros pavaros imitacinis tyrimas |
title_full | Simulation of frequency controlled electric drive using scalar control method / Skaliariniu būdu valdomos dažninės elektros pavaros imitacinis tyrimas |
title_fullStr | Simulation of frequency controlled electric drive using scalar control method / Skaliariniu būdu valdomos dažninės elektros pavaros imitacinis tyrimas |
title_full_unstemmed | Simulation of frequency controlled electric drive using scalar control method / Skaliariniu būdu valdomos dažninės elektros pavaros imitacinis tyrimas |
title_short | Simulation of frequency controlled electric drive using scalar control method / Skaliariniu būdu valdomos dažninės elektros pavaros imitacinis tyrimas |
title_sort | simulation of frequency controlled electric drive using scalar control method skaliariniu budu valdomos daznines elektros pavaros imitacinis tyrimas |
topic | frequency controlled drive scalar control simulation model |
url | http://journals.vgtu.lt/index.php/MLA/article/view/3811 |
work_keys_str_mv | AT jonaskriauciunas simulationoffrequencycontrolledelectricdriveusingscalarcontrolmethodskaliariniubuduvaldomosdaznineselektrospavarosimitacinistyrimas AT laurynaskerpe simulationoffrequencycontrolledelectricdriveusingscalarcontrolmethodskaliariniubuduvaldomosdaznineselektrospavarosimitacinistyrimas |