Light chain immunofluorescence in various nephropathies

Context: Light chain immunofluoresence (IF) in renal biopsy is routinely used in the diagnosis of light chain deposition disease (LCDD), amyloidosis and cast nephropathy. Light chain predominance has also been reported in certain glomerulopathies like IgA nephropathy. However, pathogenesis of this p...

Full description

Bibliographic Details
Main Authors: Megha S Uppin, Aruna K Prayaga, B H Srinivas, Ram Rapur, Madhav Desai, K V Dakshina Murthy
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2011-01-01
Series:Indian Journal of Pathology and Microbiology
Subjects:
Online Access:http://www.ijpmonline.org/article.asp?issn=0377-4929;year=2011;volume=54;issue=1;spage=55;epage=58;aulast=Uppin
_version_ 1828255911723925504
author Megha S Uppin
Aruna K Prayaga
B H Srinivas
Ram Rapur
Madhav Desai
K V Dakshina Murthy
author_facet Megha S Uppin
Aruna K Prayaga
B H Srinivas
Ram Rapur
Madhav Desai
K V Dakshina Murthy
author_sort Megha S Uppin
collection DOAJ
description Context: Light chain immunofluoresence (IF) in renal biopsy is routinely used in the diagnosis of light chain deposition disease (LCDD), amyloidosis and cast nephropathy. Light chain predominance has also been reported in certain glomerulopathies like IgA nephropathy. However, pathogenesis of this pattern of deposition in various glomerulopathies is uncertain. Aim: To discuss the pathogenesis and utility of light chain IF in nephropathies. Setting and Design: Retrospective study. Materials and Methods: The pattern of light chain IF and light microscopic diagnosis in 306 cases of various nephropathies was reviewed. Direct IF was done in all these cases with commercial fluorescence (Fluoresciene Isothiocynate ) conjugated polyclonal rabbit anti-human antisera against IgM, IgG, IgA, C3, C1q, kappa and lambda light chains. Results: Light chain deposits were seen in 240 (78.43%) cases. In IgA nephropathy, lupus nephritis and post-infectious glomerulonephritis (PIGN), lambda positivity was more as compared to kappa. Light chain deposits in LCDD and membranous nephropathy were more kappa type. The IF pattern in amyloidosis was not consistent. Conclusion: The pathogenesis of light chain predominance in glomerulopathies is not clear and it depends on isoelectric point and size of the immune complex. Light chain IF should be performed routinely in all the renal biopsies.
first_indexed 2024-04-13T02:20:43Z
format Article
id doaj.art-f895e06f9e4f49b3bee8fcd492e97c0f
institution Directory Open Access Journal
issn 0377-4929
language English
last_indexed 2024-04-13T02:20:43Z
publishDate 2011-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Indian Journal of Pathology and Microbiology
spelling doaj.art-f895e06f9e4f49b3bee8fcd492e97c0f2022-12-22T03:06:59ZengWolters Kluwer Medknow PublicationsIndian Journal of Pathology and Microbiology0377-49292011-01-01541555810.4103/0377-4929.77325Light chain immunofluorescence in various nephropathiesMegha S UppinAruna K PrayagaB H SrinivasRam RapurMadhav DesaiK V Dakshina MurthyContext: Light chain immunofluoresence (IF) in renal biopsy is routinely used in the diagnosis of light chain deposition disease (LCDD), amyloidosis and cast nephropathy. Light chain predominance has also been reported in certain glomerulopathies like IgA nephropathy. However, pathogenesis of this pattern of deposition in various glomerulopathies is uncertain. Aim: To discuss the pathogenesis and utility of light chain IF in nephropathies. Setting and Design: Retrospective study. Materials and Methods: The pattern of light chain IF and light microscopic diagnosis in 306 cases of various nephropathies was reviewed. Direct IF was done in all these cases with commercial fluorescence (Fluoresciene Isothiocynate ) conjugated polyclonal rabbit anti-human antisera against IgM, IgG, IgA, C3, C1q, kappa and lambda light chains. Results: Light chain deposits were seen in 240 (78.43%) cases. In IgA nephropathy, lupus nephritis and post-infectious glomerulonephritis (PIGN), lambda positivity was more as compared to kappa. Light chain deposits in LCDD and membranous nephropathy were more kappa type. The IF pattern in amyloidosis was not consistent. Conclusion: The pathogenesis of light chain predominance in glomerulopathies is not clear and it depends on isoelectric point and size of the immune complex. Light chain IF should be performed routinely in all the renal biopsies.http://www.ijpmonline.org/article.asp?issn=0377-4929;year=2011;volume=54;issue=1;spage=55;epage=58;aulast=UppinGlomerulopathyimmunofluorescencelight chain immun-ofluorescencepathogenesisrenal biopsy
spellingShingle Megha S Uppin
Aruna K Prayaga
B H Srinivas
Ram Rapur
Madhav Desai
K V Dakshina Murthy
Light chain immunofluorescence in various nephropathies
Indian Journal of Pathology and Microbiology
Glomerulopathy
immunofluorescence
light chain immun-ofluorescence
pathogenesis
renal biopsy
title Light chain immunofluorescence in various nephropathies
title_full Light chain immunofluorescence in various nephropathies
title_fullStr Light chain immunofluorescence in various nephropathies
title_full_unstemmed Light chain immunofluorescence in various nephropathies
title_short Light chain immunofluorescence in various nephropathies
title_sort light chain immunofluorescence in various nephropathies
topic Glomerulopathy
immunofluorescence
light chain immun-ofluorescence
pathogenesis
renal biopsy
url http://www.ijpmonline.org/article.asp?issn=0377-4929;year=2011;volume=54;issue=1;spage=55;epage=58;aulast=Uppin
work_keys_str_mv AT meghasuppin lightchainimmunofluorescenceinvariousnephropathies
AT arunakprayaga lightchainimmunofluorescenceinvariousnephropathies
AT bhsrinivas lightchainimmunofluorescenceinvariousnephropathies
AT ramrapur lightchainimmunofluorescenceinvariousnephropathies
AT madhavdesai lightchainimmunofluorescenceinvariousnephropathies
AT kvdakshinamurthy lightchainimmunofluorescenceinvariousnephropathies