Evaluation and additional recommendations for preparing a whole blood control material Avaliação e recomendações adicionais para a preparação de material sangüíneo integral para controles

OBJECTIVE: The assessment of an easy to prepare and low cost control material for Hematology, available for manual and automated methods. MATERIAL AND METHOD: Aliquots of stabilized whole blood were prepared by partial fixation with aldehydes; the stability at different temperatures (4. 20 and 37 °C...

Full description

Bibliographic Details
Main Authors: Nilda E. Fink, Alejandra Fernández Alberti, Isabel Crispini, Norberto V. Cabutti, Daniel Mazziotta
Format: Article
Language:English
Published: Universidade de São Paulo 1998-04-01
Series:Revista de Saúde Pública
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0034-89101998000200001
_version_ 1818425986074542080
author Nilda E. Fink
Alejandra Fernández Alberti
Isabel Crispini
Norberto V. Cabutti
Daniel Mazziotta
author_facet Nilda E. Fink
Alejandra Fernández Alberti
Isabel Crispini
Norberto V. Cabutti
Daniel Mazziotta
author_sort Nilda E. Fink
collection DOAJ
description OBJECTIVE: The assessment of an easy to prepare and low cost control material for Hematology, available for manual and automated methods. MATERIAL AND METHOD: Aliquots of stabilized whole blood were prepared by partial fixation with aldehydes; the stability at different temperatures (4. 20 and 37 °C) during periods of up to 8-9 weeks and aliquot variability with both methods were controlled. RESULTS: Aliquot variability with automated methods at day 1, expressed as CV% (coefficient of variation) was: white blood cells (WBC) 2.7, red blood cells (RBC) 0.7, hemoglobin (Hb) 0.6, hematocrit (Hct) 0.7, mean cell volume (MCV) 0.3, mean cell hemoglobin (MCH) 0.6, mean cell hemoglobin concentration (MCHC) 0.7, and platelets (PLT) 4.6. The CV (coefficient of variation) percentages obtained with manual methods in one of the batches were: WBC 23, Hct 2.8, Hb 4.5, MCHC 5.9, PLT 41. Samples stored at 4ºC and 20ºC showed good stability, only a very low initial hemolysis being observed, whereas those stored at 37ºC deteriobed a rapidly (metahemoglobin formation, aggregation of WBC and platelets, as well as alteration of erythrocyte indexes). CONCLUSIONS: It was confirmed that, as long as there is no exposure to high temperatures during distribution, this material is stable, allowing assessment, both esternal and internal, for control purposes, with acceptable reproductivity, both for manual and auttomatic methods.<br>OBJETIVO: Avaliar material de controle para hematologia, de fácil preparação e baixo custo, que poderá ser usado por métodos manuais e automatizados. MATERIAL E MÉTODO: Alíquotas de sangue estabilizado foram preparadas por fixação parcial com aldeídos. Foram estudadas a estabilidade a diferentes temperaturas (4, 20, 37ºC) durante períodos de até 8-9 semanas e a variabilidade das alíquotas para ambos os métodos. RESULTADOS: A variabilidade entre alíquotas, expressada em CV% (coeficiente de variação) com métodos automatizados no primero dia, foi: glóbulos blancos (WBC) 2,7, glóbulos vermelhos (RBC) 0,7, hemoglobina (Hb) 0,6, hematócrito (Hct) 0,7, volume corpuscular médio (MCV) 0,3, Hb corpuscular médio (MCH) 0,3, concentração de Hb corpuscular médio (MCHC) 0,7 e plaquetas (Plt) 4,6. O CV% obtido com métodos manuais para um dos grupos foi: WBC 23, Hct 2,8, Hb 4,5, MCHC 5,9, Plt 41. As amostras conservadas a 4 e 20ºC foram estáveis, observando-se leve hemólise inicial, enquanto que as amostras conservadas a 37ºC mostraram uma rápida decomposição (formação de metaemoglobina, agregação de glóbulos brancos e plaquetas e alteração de índices). CONCLUSÕES: Confirmou-se que, se não houver exposição a altas temperaturas durante a distribuição, este material é estável, permitindo avaliação, tanto externa como interna para controle e com reprodutividade aceitável, tanto para métodos manuais como automáticos.
first_indexed 2024-12-14T14:22:39Z
format Article
id doaj.art-f8e4785678cc42699d700c7f6cb0f1e3
institution Directory Open Access Journal
issn 0034-8910
1518-8787
language English
last_indexed 2024-12-14T14:22:39Z
publishDate 1998-04-01
publisher Universidade de São Paulo
record_format Article
series Revista de Saúde Pública
spelling doaj.art-f8e4785678cc42699d700c7f6cb0f1e32022-12-21T22:58:02ZengUniversidade de São PauloRevista de Saúde Pública0034-89101518-87871998-04-0132210711110.1590/S0034-89101998000200001Evaluation and additional recommendations for preparing a whole blood control material Avaliação e recomendações adicionais para a preparação de material sangüíneo integral para controlesNilda E. FinkAlejandra Fernández AlbertiIsabel CrispiniNorberto V. CabuttiDaniel MazziottaOBJECTIVE: The assessment of an easy to prepare and low cost control material for Hematology, available for manual and automated methods. MATERIAL AND METHOD: Aliquots of stabilized whole blood were prepared by partial fixation with aldehydes; the stability at different temperatures (4. 20 and 37 °C) during periods of up to 8-9 weeks and aliquot variability with both methods were controlled. RESULTS: Aliquot variability with automated methods at day 1, expressed as CV% (coefficient of variation) was: white blood cells (WBC) 2.7, red blood cells (RBC) 0.7, hemoglobin (Hb) 0.6, hematocrit (Hct) 0.7, mean cell volume (MCV) 0.3, mean cell hemoglobin (MCH) 0.6, mean cell hemoglobin concentration (MCHC) 0.7, and platelets (PLT) 4.6. The CV (coefficient of variation) percentages obtained with manual methods in one of the batches were: WBC 23, Hct 2.8, Hb 4.5, MCHC 5.9, PLT 41. Samples stored at 4ºC and 20ºC showed good stability, only a very low initial hemolysis being observed, whereas those stored at 37ºC deteriobed a rapidly (metahemoglobin formation, aggregation of WBC and platelets, as well as alteration of erythrocyte indexes). CONCLUSIONS: It was confirmed that, as long as there is no exposure to high temperatures during distribution, this material is stable, allowing assessment, both esternal and internal, for control purposes, with acceptable reproductivity, both for manual and auttomatic methods.<br>OBJETIVO: Avaliar material de controle para hematologia, de fácil preparação e baixo custo, que poderá ser usado por métodos manuais e automatizados. MATERIAL E MÉTODO: Alíquotas de sangue estabilizado foram preparadas por fixação parcial com aldeídos. Foram estudadas a estabilidade a diferentes temperaturas (4, 20, 37ºC) durante períodos de até 8-9 semanas e a variabilidade das alíquotas para ambos os métodos. RESULTADOS: A variabilidade entre alíquotas, expressada em CV% (coeficiente de variação) com métodos automatizados no primero dia, foi: glóbulos blancos (WBC) 2,7, glóbulos vermelhos (RBC) 0,7, hemoglobina (Hb) 0,6, hematócrito (Hct) 0,7, volume corpuscular médio (MCV) 0,3, Hb corpuscular médio (MCH) 0,3, concentração de Hb corpuscular médio (MCHC) 0,7 e plaquetas (Plt) 4,6. O CV% obtido com métodos manuais para um dos grupos foi: WBC 23, Hct 2,8, Hb 4,5, MCHC 5,9, Plt 41. As amostras conservadas a 4 e 20ºC foram estáveis, observando-se leve hemólise inicial, enquanto que as amostras conservadas a 37ºC mostraram uma rápida decomposição (formação de metaemoglobina, agregação de glóbulos brancos e plaquetas e alteração de índices). CONCLUSÕES: Confirmou-se que, se não houver exposição a altas temperaturas durante a distribuição, este material é estável, permitindo avaliação, tanto externa como interna para controle e com reprodutividade aceitável, tanto para métodos manuais como automáticos.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0034-89101998000200001SangueControle de qualidadeLaboratóriosBloodQuality controlLaboratories
spellingShingle Nilda E. Fink
Alejandra Fernández Alberti
Isabel Crispini
Norberto V. Cabutti
Daniel Mazziotta
Evaluation and additional recommendations for preparing a whole blood control material Avaliação e recomendações adicionais para a preparação de material sangüíneo integral para controles
Revista de Saúde Pública
Sangue
Controle de qualidade
Laboratórios
Blood
Quality control
Laboratories
title Evaluation and additional recommendations for preparing a whole blood control material Avaliação e recomendações adicionais para a preparação de material sangüíneo integral para controles
title_full Evaluation and additional recommendations for preparing a whole blood control material Avaliação e recomendações adicionais para a preparação de material sangüíneo integral para controles
title_fullStr Evaluation and additional recommendations for preparing a whole blood control material Avaliação e recomendações adicionais para a preparação de material sangüíneo integral para controles
title_full_unstemmed Evaluation and additional recommendations for preparing a whole blood control material Avaliação e recomendações adicionais para a preparação de material sangüíneo integral para controles
title_short Evaluation and additional recommendations for preparing a whole blood control material Avaliação e recomendações adicionais para a preparação de material sangüíneo integral para controles
title_sort evaluation and additional recommendations for preparing a whole blood control material avaliacao e recomendacoes adicionais para a preparacao de material sanguineo integral para controles
topic Sangue
Controle de qualidade
Laboratórios
Blood
Quality control
Laboratories
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0034-89101998000200001
work_keys_str_mv AT nildaefink evaluationandadditionalrecommendationsforpreparingawholebloodcontrolmaterialavaliacaoerecomendacoesadicionaisparaapreparacaodematerialsanguineointegralparacontroles
AT alejandrafernandezalberti evaluationandadditionalrecommendationsforpreparingawholebloodcontrolmaterialavaliacaoerecomendacoesadicionaisparaapreparacaodematerialsanguineointegralparacontroles
AT isabelcrispini evaluationandadditionalrecommendationsforpreparingawholebloodcontrolmaterialavaliacaoerecomendacoesadicionaisparaapreparacaodematerialsanguineointegralparacontroles
AT norbertovcabutti evaluationandadditionalrecommendationsforpreparingawholebloodcontrolmaterialavaliacaoerecomendacoesadicionaisparaapreparacaodematerialsanguineointegralparacontroles
AT danielmazziotta evaluationandadditionalrecommendationsforpreparingawholebloodcontrolmaterialavaliacaoerecomendacoesadicionaisparaapreparacaodematerialsanguineointegralparacontroles