A Comparative Energy and Economic Analysis between a Low Enthalpy Geothermal Design and Gas, Diesel and Biomass Technologies for a HVAC System Installed in an Office Building
This paper presents an analysis of economic and energy between a ground-coupled heat pump system and other available technologies, such as natural gas, biomass, and diesel, providing heating, ventilation, and air conditioning to an office building. All the proposed systems are capable of reaching te...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2019-03-01
|
Series: | Energies |
Subjects: | |
Online Access: | http://www.mdpi.com/1996-1073/12/5/870 |
_version_ | 1828358429830283264 |
---|---|
author | José Ignacio Villarino Alberto Villarino I. de Arteaga Roberto Quinteros Alejandro Alañón |
author_facet | José Ignacio Villarino Alberto Villarino I. de Arteaga Roberto Quinteros Alejandro Alañón |
author_sort | José Ignacio Villarino |
collection | DOAJ |
description | This paper presents an analysis of economic and energy between a ground-coupled heat pump system and other available technologies, such as natural gas, biomass, and diesel, providing heating, ventilation, and air conditioning to an office building. All the proposed systems are capable of reaching temperatures of 22 °C/25 °C in heating and cooling modes. EnergyPlus software was used to develop a simulation model and carry out the validation process. The first objective of the paper is the validation of the numerical model developed in EnergyPlus with the experimental results collected from the monitored building to evaluate the system in other operating conditions and to compare it with other available technologies. The second aim of the study is the assessment of the position of the low enthalpy geothermal system proposed versus the rest of the systems, from energy, economic, and environmental aspects. In addition, the annual heating and cooling seasonal energy efficiency ratio (COPsys) of the ground-coupled heat pump (GCHP) shown is higher than the others. The economic results determine a period between 6 and 9 years for the proposed GCHP system to have lower economic cost than the rest of the systems. The results obtained determine that the GCHP proposed system can satisfy the thermal demand in heating and cooling conditions, with optimal environmental values and economic viability. |
first_indexed | 2024-04-14T03:29:40Z |
format | Article |
id | doaj.art-f963fcd7e1f94382882e75361abb4dfd |
institution | Directory Open Access Journal |
issn | 1996-1073 |
language | English |
last_indexed | 2024-04-14T03:29:40Z |
publishDate | 2019-03-01 |
publisher | MDPI AG |
record_format | Article |
series | Energies |
spelling | doaj.art-f963fcd7e1f94382882e75361abb4dfd2022-12-22T02:15:01ZengMDPI AGEnergies1996-10732019-03-0112587010.3390/en12050870en12050870A Comparative Energy and Economic Analysis between a Low Enthalpy Geothermal Design and Gas, Diesel and Biomass Technologies for a HVAC System Installed in an Office BuildingJosé Ignacio Villarino0Alberto Villarino1I. de Arteaga2Roberto Quinteros3Alejandro Alañón4Department of Construction and Agronomy, Construction Engineering Area, High Polytechnic School of Ávila, University of Salamanca, Hornos Caleros, 50, 05003 Ávila, SpainDepartment of Construction and Agronomy, Construction Engineering Area, High Polytechnic School of Ávila, University of Salamanca, Hornos Caleros, 50, 05003 Ávila, SpainFacultad de Ingeniería, Escuela de Ingeniería Mecánica, Pontificia Universidad Católica de Valparaíso, Av. Los Carrera 01567, Quilpué 2430000, ChileFacultad de Ingeniería, Escuela de Ingeniería Mecánica, Pontificia Universidad Católica de Valparaíso, Av. Los Carrera 01567, Quilpué 2430000, ChileDepartment of Construction and Agronomy, Construction Engineering Area, High Polytechnic School of Ávila, University of Salamanca, Hornos Caleros, 50, 05003 Ávila, SpainThis paper presents an analysis of economic and energy between a ground-coupled heat pump system and other available technologies, such as natural gas, biomass, and diesel, providing heating, ventilation, and air conditioning to an office building. All the proposed systems are capable of reaching temperatures of 22 °C/25 °C in heating and cooling modes. EnergyPlus software was used to develop a simulation model and carry out the validation process. The first objective of the paper is the validation of the numerical model developed in EnergyPlus with the experimental results collected from the monitored building to evaluate the system in other operating conditions and to compare it with other available technologies. The second aim of the study is the assessment of the position of the low enthalpy geothermal system proposed versus the rest of the systems, from energy, economic, and environmental aspects. In addition, the annual heating and cooling seasonal energy efficiency ratio (COPsys) of the ground-coupled heat pump (GCHP) shown is higher than the others. The economic results determine a period between 6 and 9 years for the proposed GCHP system to have lower economic cost than the rest of the systems. The results obtained determine that the GCHP proposed system can satisfy the thermal demand in heating and cooling conditions, with optimal environmental values and economic viability.http://www.mdpi.com/1996-1073/12/5/870low enthalpy geothermal systemrenewable energysimulation modelsenergy analysiseconomic feasibility |
spellingShingle | José Ignacio Villarino Alberto Villarino I. de Arteaga Roberto Quinteros Alejandro Alañón A Comparative Energy and Economic Analysis between a Low Enthalpy Geothermal Design and Gas, Diesel and Biomass Technologies for a HVAC System Installed in an Office Building Energies low enthalpy geothermal system renewable energy simulation models energy analysis economic feasibility |
title | A Comparative Energy and Economic Analysis between a Low Enthalpy Geothermal Design and Gas, Diesel and Biomass Technologies for a HVAC System Installed in an Office Building |
title_full | A Comparative Energy and Economic Analysis between a Low Enthalpy Geothermal Design and Gas, Diesel and Biomass Technologies for a HVAC System Installed in an Office Building |
title_fullStr | A Comparative Energy and Economic Analysis between a Low Enthalpy Geothermal Design and Gas, Diesel and Biomass Technologies for a HVAC System Installed in an Office Building |
title_full_unstemmed | A Comparative Energy and Economic Analysis between a Low Enthalpy Geothermal Design and Gas, Diesel and Biomass Technologies for a HVAC System Installed in an Office Building |
title_short | A Comparative Energy and Economic Analysis between a Low Enthalpy Geothermal Design and Gas, Diesel and Biomass Technologies for a HVAC System Installed in an Office Building |
title_sort | comparative energy and economic analysis between a low enthalpy geothermal design and gas diesel and biomass technologies for a hvac system installed in an office building |
topic | low enthalpy geothermal system renewable energy simulation models energy analysis economic feasibility |
url | http://www.mdpi.com/1996-1073/12/5/870 |
work_keys_str_mv | AT joseignaciovillarino acomparativeenergyandeconomicanalysisbetweenalowenthalpygeothermaldesignandgasdieselandbiomasstechnologiesforahvacsysteminstalledinanofficebuilding AT albertovillarino acomparativeenergyandeconomicanalysisbetweenalowenthalpygeothermaldesignandgasdieselandbiomasstechnologiesforahvacsysteminstalledinanofficebuilding AT idearteaga acomparativeenergyandeconomicanalysisbetweenalowenthalpygeothermaldesignandgasdieselandbiomasstechnologiesforahvacsysteminstalledinanofficebuilding AT robertoquinteros acomparativeenergyandeconomicanalysisbetweenalowenthalpygeothermaldesignandgasdieselandbiomasstechnologiesforahvacsysteminstalledinanofficebuilding AT alejandroalanon acomparativeenergyandeconomicanalysisbetweenalowenthalpygeothermaldesignandgasdieselandbiomasstechnologiesforahvacsysteminstalledinanofficebuilding AT joseignaciovillarino comparativeenergyandeconomicanalysisbetweenalowenthalpygeothermaldesignandgasdieselandbiomasstechnologiesforahvacsysteminstalledinanofficebuilding AT albertovillarino comparativeenergyandeconomicanalysisbetweenalowenthalpygeothermaldesignandgasdieselandbiomasstechnologiesforahvacsysteminstalledinanofficebuilding AT idearteaga comparativeenergyandeconomicanalysisbetweenalowenthalpygeothermaldesignandgasdieselandbiomasstechnologiesforahvacsysteminstalledinanofficebuilding AT robertoquinteros comparativeenergyandeconomicanalysisbetweenalowenthalpygeothermaldesignandgasdieselandbiomasstechnologiesforahvacsysteminstalledinanofficebuilding AT alejandroalanon comparativeenergyandeconomicanalysisbetweenalowenthalpygeothermaldesignandgasdieselandbiomasstechnologiesforahvacsysteminstalledinanofficebuilding |