EVALUATION OF STRENGTH CHARACTERISTICS OF CORONARY STENTS IN THE CREATED MODEL OF “MYOCARDIAL BRIDGE”

Introduction. Presently there is no unified tactics to treat patients with aberrantly localized coronary arteries of “muscular bridge” type. There are controversial data regarding the benefit of coronary artery stenting due to often stent breakage or perforation of tunneled vessel. There are no majo...

Full description

Bibliographic Details
Main Authors: V. V. Plechev, T. Sh. Sagatdinov, R. Yu. Rizberg, I. V. Buzaev, I. E. Nikolaeva, B. A. Oleynik
Format: Article
Language:English
Published: Bashkir State Medical University 2018-08-01
Series:Креативная хирургия и онкология
Subjects:
Online Access:https://www.surgonco.ru/jour/article/view/302
_version_ 1797872388038197248
author V. V. Plechev
T. Sh. Sagatdinov
R. Yu. Rizberg
I. V. Buzaev
I. E. Nikolaeva
B. A. Oleynik
author_facet V. V. Plechev
T. Sh. Sagatdinov
R. Yu. Rizberg
I. V. Buzaev
I. E. Nikolaeva
B. A. Oleynik
author_sort V. V. Plechev
collection DOAJ
description Introduction. Presently there is no unified tactics to treat patients with aberrantly localized coronary arteries of “muscular bridge” type. There are controversial data regarding the benefit of coronary artery stenting due to often stent breakage or perforation of tunneled vessel. There are no major randomized studies regarding this issue. In this regard the goal of this research was to assess strength characteristics of stents in the model of muscular growth that we restored.Materials and methods. The originally developed model enabled to determine the strength limit of coronary stents under conditions that are maximum close to the physiological ones. The stents were placed into a polytetrafluoroethylene tube, the bridge-imitating oscillation frequency was configured to 250 beats per minute. The results of the experiment were recorded on USB-camera each 30 minutes in order to register mechanical defects of the stent.Results and discussion. The stent consisting of cells that are joined with V-shaped connections, showed first signs of strut deformity on the 10th day. Complete breakage happened on the 17th day after implantation. After 2 months observation the stent preserved mechanical firmness without V-shaped connections.Conclusion. Thus, it is not quite correct to support the hypothesis on infeasibility of stent implantation into the coronary artery with a muscular bridge. Taking into consideration the findings it is possible to suppose that the structure, design, form and content of stents predetermine the possibility to implant it into coronary artery with muscular bridge, but require individual approach to every particular patient.
first_indexed 2024-04-10T00:59:04Z
format Article
id doaj.art-faf5ad132429450ca21fa1dd34f87947
institution Directory Open Access Journal
issn 2307-0501
2076-3093
language English
last_indexed 2024-04-10T00:59:04Z
publishDate 2018-08-01
publisher Bashkir State Medical University
record_format Article
series Креативная хирургия и онкология
spelling doaj.art-faf5ad132429450ca21fa1dd34f879472023-03-13T10:01:08ZengBashkir State Medical UniversityКреативная хирургия и онкология2307-05012076-30932018-08-0181646810.24060/2076-3093-2018-8-1-64-68264EVALUATION OF STRENGTH CHARACTERISTICS OF CORONARY STENTS IN THE CREATED MODEL OF “MYOCARDIAL BRIDGE”V. V. Plechev0T. Sh. Sagatdinov1R. Yu. Rizberg2I. V. Buzaev3I. E. Nikolaeva4B. A. Oleynik5Башкирский государственный медицинский университетРеспубликанский кардиологический центрРеспубликанский кардиологический центрРеспубликанский кардиологический центрРеспубликанский кардиологический центрРеспубликанский кардиологический центр; Башкирский государственный медицинский университетIntroduction. Presently there is no unified tactics to treat patients with aberrantly localized coronary arteries of “muscular bridge” type. There are controversial data regarding the benefit of coronary artery stenting due to often stent breakage or perforation of tunneled vessel. There are no major randomized studies regarding this issue. In this regard the goal of this research was to assess strength characteristics of stents in the model of muscular growth that we restored.Materials and methods. The originally developed model enabled to determine the strength limit of coronary stents under conditions that are maximum close to the physiological ones. The stents were placed into a polytetrafluoroethylene tube, the bridge-imitating oscillation frequency was configured to 250 beats per minute. The results of the experiment were recorded on USB-camera each 30 minutes in order to register mechanical defects of the stent.Results and discussion. The stent consisting of cells that are joined with V-shaped connections, showed first signs of strut deformity on the 10th day. Complete breakage happened on the 17th day after implantation. After 2 months observation the stent preserved mechanical firmness without V-shaped connections.Conclusion. Thus, it is not quite correct to support the hypothesis on infeasibility of stent implantation into the coronary artery with a muscular bridge. Taking into consideration the findings it is possible to suppose that the structure, design, form and content of stents predetermine the possibility to implant it into coronary artery with muscular bridge, but require individual approach to every particular patient.https://www.surgonco.ru/jour/article/view/302мышечные мостыишемическая болезнь сердцакоронарные стентыбиологические модели
spellingShingle V. V. Plechev
T. Sh. Sagatdinov
R. Yu. Rizberg
I. V. Buzaev
I. E. Nikolaeva
B. A. Oleynik
EVALUATION OF STRENGTH CHARACTERISTICS OF CORONARY STENTS IN THE CREATED MODEL OF “MYOCARDIAL BRIDGE”
Креативная хирургия и онкология
мышечные мосты
ишемическая болезнь сердца
коронарные стенты
биологические модели
title EVALUATION OF STRENGTH CHARACTERISTICS OF CORONARY STENTS IN THE CREATED MODEL OF “MYOCARDIAL BRIDGE”
title_full EVALUATION OF STRENGTH CHARACTERISTICS OF CORONARY STENTS IN THE CREATED MODEL OF “MYOCARDIAL BRIDGE”
title_fullStr EVALUATION OF STRENGTH CHARACTERISTICS OF CORONARY STENTS IN THE CREATED MODEL OF “MYOCARDIAL BRIDGE”
title_full_unstemmed EVALUATION OF STRENGTH CHARACTERISTICS OF CORONARY STENTS IN THE CREATED MODEL OF “MYOCARDIAL BRIDGE”
title_short EVALUATION OF STRENGTH CHARACTERISTICS OF CORONARY STENTS IN THE CREATED MODEL OF “MYOCARDIAL BRIDGE”
title_sort evaluation of strength characteristics of coronary stents in the created model of myocardial bridge
topic мышечные мосты
ишемическая болезнь сердца
коронарные стенты
биологические модели
url https://www.surgonco.ru/jour/article/view/302
work_keys_str_mv AT vvplechev evaluationofstrengthcharacteristicsofcoronarystentsinthecreatedmodelofmyocardialbridge
AT tshsagatdinov evaluationofstrengthcharacteristicsofcoronarystentsinthecreatedmodelofmyocardialbridge
AT ryurizberg evaluationofstrengthcharacteristicsofcoronarystentsinthecreatedmodelofmyocardialbridge
AT ivbuzaev evaluationofstrengthcharacteristicsofcoronarystentsinthecreatedmodelofmyocardialbridge
AT ienikolaeva evaluationofstrengthcharacteristicsofcoronarystentsinthecreatedmodelofmyocardialbridge
AT baoleynik evaluationofstrengthcharacteristicsofcoronarystentsinthecreatedmodelofmyocardialbridge