INCREASING THE EFFICIENCY OF AIR CONDITIONING SYSTEMS BY DISTRIBUTING THE THERMAL LOAD ACCORDING TO THE STAGE PRINCIPLE

Maintaining the operation of refrigeration compressors in nominal or close modes by selecting a rational design thermal load and distributing it in response to the behavior of the current thermal load according to the current climatic conditions is one of the promising reserves for improving the ene...

Full description

Bibliographic Details
Main Authors: Євген Іванович Трушляков, Микола Іванович Радченко, Андрій Миколайович Радченко, Сергій Георгійович Фордуй, Сергій Анатолійович Кантор, Веніамін Сергійович Ткаченко, Богдан Сергійович Портной
Format: Article
Language:English
Published: National Aerospace University «Kharkiv Aviation Institute» 2019-08-01
Series:Авіаційно-космічна техніка та технологія
Subjects:
Online Access:http://nti.khai.edu/ojs/index.php/aktt/article/view/864
Description
Summary:Maintaining the operation of refrigeration compressors in nominal or close modes by selecting a rational design thermal load and distributing it in response to the behavior of the current thermal load according to the current climatic conditions is one of the promising reserves for improving the energy efficiency of air conditioning systems, which implementation ensures maximum or close to it in the annual cooling production according to air conditioning duties. In general case, the total range of current thermal loads of any air-conditioning system includes a range of unstable loads caused by precooling of ambient air with significant fluctuations in the cooling capacity according to current climatic conditions, and a range of relatively stable cooling capacity expended for further lowering the air temperature from a certain threshold temperature to the final outlet temperature. If a range of stable thermal load can be provided within operating a conventional compressor in a mode close to nominal, then precooling the ambient air with significant fluctuations in thermal load requires adjusting the cooling capacity by using a variable speed compressor or using the excess of heat accumulated at reduced load. Such a stage principle of cooling ensures the operation of refrigerating machines matching the behavior of current thermal loads of any air-conditioning system, whether the central air conditioning system with ambient air procession in the central air conditioner or its combination with the local indoors recirculation air conditioning systems in the air-conditioning system. in essence, as combinations of subsystems – precooling of ambient air with the regulation of cooling capacity and subsequent cooling air to the mouth of the set point temperature under relatively stable thermal load.
ISSN:1727-7337
2663-2217