Structural behavior of steel slit damper in steel beam to column connection

ABSTRACTMost of the steel moment resisting frames, damage at the beam-to-column connections during seismic loads. Application of passive dampers in order to prevent damages to the main components of structure has been an interesting subject for many researchers recently. In this present study, perf...

Full description

Bibliographic Details
Main Authors: Omid Kohnehpooshi, Afrasyab Salem
Format: Article
Language:fas
Published: Iranian Society of Structrual Engineering (ISSE) 2020-03-01
Series:Journal of Structural and Construction Engineering
Subjects:
Online Access:https://www.jsce.ir/article_66328_7e0ec448bbb87ae292f07f1a70ed4a73.pdf
_version_ 1819006714669694976
author Omid Kohnehpooshi
Afrasyab Salem
author_facet Omid Kohnehpooshi
Afrasyab Salem
author_sort Omid Kohnehpooshi
collection DOAJ
description ABSTRACTMost of the steel moment resisting frames, damage at the beam-to-column connections during seismic loads. Application of passive dampers in order to prevent damages to the main components of structure has been an interesting subject for many researchers recently. In this present study, performance of the metallic yield damper is slit steel damper (SSD) on the steel beam-to-column connection is carried out using finite element model. Thus, first this damper and its connection is simulated. After validation of results, the effect of various dimensional parameters including radius slot, of damper on the performance of damper and its connection was investigated. Then various forms of this damper simulated and their effect on the performance of damper and the steel beam-to-column connection is studied. Moment- rotation, Hysteresis curves and plastic strains for each size of radius slot and different shapes extracted from the analysis were compared. Furthermore base shear force for steel frames with and without slit dampers in term of energy absorption and deformation are compared together. Findings indicated seismic behavior fitted to such dampers. The results indicate that the slit damper shows a proper function in absorbing energy. Recommendation for appropriate size and shape of slit steel dampers proposed.
first_indexed 2024-12-21T00:13:05Z
format Article
id doaj.art-fba087dabc994c3fa1116545b5803677
institution Directory Open Access Journal
issn 2476-3977
2538-2616
language fas
last_indexed 2024-12-21T00:13:05Z
publishDate 2020-03-01
publisher Iranian Society of Structrual Engineering (ISSE)
record_format Article
series Journal of Structural and Construction Engineering
spelling doaj.art-fba087dabc994c3fa1116545b58036772022-12-21T19:22:18ZfasIranian Society of Structrual Engineering (ISSE)Journal of Structural and Construction Engineering2476-39772538-26162020-03-0171264010.22065/jsce.2018.112329.141666328Structural behavior of steel slit damper in steel beam to column connectionOmid Kohnehpooshi0Afrasyab Salem1Department Of Civil Engineering, Faculty Of Engineering, Islamic Azad University, Sanandaj,Irangraduated M.Sc of Civil Engineering. Islamic Azad university, Sannadaj Branch, Sanandaj, IranABSTRACTMost of the steel moment resisting frames, damage at the beam-to-column connections during seismic loads. Application of passive dampers in order to prevent damages to the main components of structure has been an interesting subject for many researchers recently. In this present study, performance of the metallic yield damper is slit steel damper (SSD) on the steel beam-to-column connection is carried out using finite element model. Thus, first this damper and its connection is simulated. After validation of results, the effect of various dimensional parameters including radius slot, of damper on the performance of damper and its connection was investigated. Then various forms of this damper simulated and their effect on the performance of damper and the steel beam-to-column connection is studied. Moment- rotation, Hysteresis curves and plastic strains for each size of radius slot and different shapes extracted from the analysis were compared. Furthermore base shear force for steel frames with and without slit dampers in term of energy absorption and deformation are compared together. Findings indicated seismic behavior fitted to such dampers. The results indicate that the slit damper shows a proper function in absorbing energy. Recommendation for appropriate size and shape of slit steel dampers proposed.https://www.jsce.ir/article_66328_7e0ec448bbb87ae292f07f1a70ed4a73.pdfenergy dissipationpassive controlsteel slit damperfinite elementbeam to column connection
spellingShingle Omid Kohnehpooshi
Afrasyab Salem
Structural behavior of steel slit damper in steel beam to column connection
Journal of Structural and Construction Engineering
energy dissipation
passive control
steel slit damper
finite element
beam to column connection
title Structural behavior of steel slit damper in steel beam to column connection
title_full Structural behavior of steel slit damper in steel beam to column connection
title_fullStr Structural behavior of steel slit damper in steel beam to column connection
title_full_unstemmed Structural behavior of steel slit damper in steel beam to column connection
title_short Structural behavior of steel slit damper in steel beam to column connection
title_sort structural behavior of steel slit damper in steel beam to column connection
topic energy dissipation
passive control
steel slit damper
finite element
beam to column connection
url https://www.jsce.ir/article_66328_7e0ec448bbb87ae292f07f1a70ed4a73.pdf
work_keys_str_mv AT omidkohnehpooshi structuralbehaviorofsteelslitdamperinsteelbeamtocolumnconnection
AT afrasyabsalem structuralbehaviorofsteelslitdamperinsteelbeamtocolumnconnection