Nickel allergy requiring plate removal after implantation of stainless steel and titanium plates after polytrauma
The patient was a 23-year-old female involved in a motor vehicle collision. She sustained a left humerus fracture and a left posterior wall acetabular fracture, for which she underwent open reduction and internal fixation with stainless steel implants and titanium implants, respectively. At her post...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Kashan University of Medical Sciences
2022-01-01
|
Series: | Archives of Trauma Research |
Subjects: | |
Online Access: | http://www.archtrauma.com/article.asp?issn=2251-953X;year=2022;volume=11;issue=3;spage=158;epage=160;aulast=Kirchner |
_version_ | 1797724585881239552 |
---|---|
author | Gregory J Kirchner Nicholas I Pilla Andrew H Kim Henry A Boateng |
author_facet | Gregory J Kirchner Nicholas I Pilla Andrew H Kim Henry A Boateng |
author_sort | Gregory J Kirchner |
collection | DOAJ |
description | The patient was a 23-year-old female involved in a motor vehicle collision. She sustained a left humerus fracture and a left posterior wall acetabular fracture, for which she underwent open reduction and internal fixation with stainless steel implants and titanium implants, respectively. At her postoperative visits, she had erythema and itching along the humeral incision. She returned to the operating room for revision fixation with a titanium implant and reported the resolution of her symptoms. Metal hypersensitivities (MHSs) resulting in surgical complications in orthopedic trauma are rare. Patients should be screened for a history of MHS before implant selection. |
first_indexed | 2024-03-12T10:19:14Z |
format | Article |
id | doaj.art-fba60b3a5db5441b957c2e63ce6600c2 |
institution | Directory Open Access Journal |
issn | 2251-953X 2251-9599 |
language | English |
last_indexed | 2024-03-12T10:19:14Z |
publishDate | 2022-01-01 |
publisher | Kashan University of Medical Sciences |
record_format | Article |
series | Archives of Trauma Research |
spelling | doaj.art-fba60b3a5db5441b957c2e63ce6600c22023-09-02T10:18:40ZengKashan University of Medical SciencesArchives of Trauma Research2251-953X2251-95992022-01-0111315816010.4103/atr.atr_44_22Nickel allergy requiring plate removal after implantation of stainless steel and titanium plates after polytraumaGregory J KirchnerNicholas I PillaAndrew H KimHenry A BoatengThe patient was a 23-year-old female involved in a motor vehicle collision. She sustained a left humerus fracture and a left posterior wall acetabular fracture, for which she underwent open reduction and internal fixation with stainless steel implants and titanium implants, respectively. At her postoperative visits, she had erythema and itching along the humeral incision. She returned to the operating room for revision fixation with a titanium implant and reported the resolution of her symptoms. Metal hypersensitivities (MHSs) resulting in surgical complications in orthopedic trauma are rare. Patients should be screened for a history of MHS before implant selection.http://www.archtrauma.com/article.asp?issn=2251-953X;year=2022;volume=11;issue=3;spage=158;epage=160;aulast=Kirchnermetal hypersensitivitynickel allergypolytrauma |
spellingShingle | Gregory J Kirchner Nicholas I Pilla Andrew H Kim Henry A Boateng Nickel allergy requiring plate removal after implantation of stainless steel and titanium plates after polytrauma Archives of Trauma Research metal hypersensitivity nickel allergy polytrauma |
title | Nickel allergy requiring plate removal after implantation of stainless steel and titanium plates after polytrauma |
title_full | Nickel allergy requiring plate removal after implantation of stainless steel and titanium plates after polytrauma |
title_fullStr | Nickel allergy requiring plate removal after implantation of stainless steel and titanium plates after polytrauma |
title_full_unstemmed | Nickel allergy requiring plate removal after implantation of stainless steel and titanium plates after polytrauma |
title_short | Nickel allergy requiring plate removal after implantation of stainless steel and titanium plates after polytrauma |
title_sort | nickel allergy requiring plate removal after implantation of stainless steel and titanium plates after polytrauma |
topic | metal hypersensitivity nickel allergy polytrauma |
url | http://www.archtrauma.com/article.asp?issn=2251-953X;year=2022;volume=11;issue=3;spage=158;epage=160;aulast=Kirchner |
work_keys_str_mv | AT gregoryjkirchner nickelallergyrequiringplateremovalafterimplantationofstainlesssteelandtitaniumplatesafterpolytrauma AT nicholasipilla nickelallergyrequiringplateremovalafterimplantationofstainlesssteelandtitaniumplatesafterpolytrauma AT andrewhkim nickelallergyrequiringplateremovalafterimplantationofstainlesssteelandtitaniumplatesafterpolytrauma AT henryaboateng nickelallergyrequiringplateremovalafterimplantationofstainlesssteelandtitaniumplatesafterpolytrauma |